background image

 
 

 

INSTALLATION 

General 
Please  read  this  guide  completely 
before 

installing 

or 

using 

your 

Panasonic  PV  modules.  This  section 
contains 

important 

electrical 

and 

mechanical specifications. 

 

Modules  should  be  firmly  fixed  in 
place  in  a  manner  suitable  to 
withstand 

all 

expected 

loads, 

including wind and snow loads.  

 

Metals  used  in  locations  that  are 
exposed  to  moisture  shall  not  be 
employed  alone  or  in  combinations 
that  could  result  in  deterioration  or 
corrosion. 

 

Install  modules  where  they  are  not 
shaded  by  obstacles  like  buildings 
and  trees.    Pay  special  attention  to 
avoid  partially  shading  the  modules 
by objects during the daytime.  

 

If  needed,  contact  an  Authorized 
Representative 

with 

questions 

regarding  mounting  profiles  for 
Panasonic HIT

®

 
Notes on Installation  

 

Clearance  between  the  roof  surface 
and  module  frame  is  required  to 
allow  cooling  air  to  circulate  around 
the  back  of  the  module.  This  also 
allows any condensation or moisture 
to  dissipate.    Install  modules  with  a 
minimum 

of 

inch 

clearance 

between  the  roof  surface  and  the 
modules so that air can circulate. 

 

Panasonic 

recommends 

the 

installation  method  and  mounting 
profile shown in Figure 1  

 

A  module  should  be  attached  on  a 
mount  or  support  structure  rail  by 
corrosive-resistant metal clamps. 

 

The  clamps  should  be  made  of 
aluminum  alloy  or  other  material 
that  will  reasonably  protect  against 
a risk of electrolytic corrosion.   

 

Recommendation  of  bolt  torque 
range: 16N.m to 20N.m  

 

The module was  tested using Unirac 
clamps  with  the  specifications  see 
figure 1 and below;  

 

Provider: UniRac, Inc. 

 

Part number: SolarMount

®

   

 

Clamps 

type: 

Top 

Mounting  

Clamps 

 

Clamp  size:Mid  clamp  and  End 
clamp, C size, 

 

Unirac Part No. 302003, 302101  

 

Width: 1.5”(38 mm) 

 

Thickness :  0.12”(3 mm) 

  

  

  

  

Installation (reference) 

Solar Module 

Metal clamp B 
(2 places) 

Metal clamp A 
(2 places) 

Mounting 
Structure Rail 

Metal clamp B 

Solar Module 

Metal clamp A 

Mounting 

Structure 

Rail 

Metal  clamp 

Module 

Mounting Structure 

M8 Nut 

Metal clamp A 

M8 Bolt 

M8 Bolt 

M8 Nut 

End of Module 

Between Modules 

Figure 1.  Installation 

1.5” 
(38mm) 

0.12”  
(3mm) 

0.2” (5mm) 

1.37” 
(35mm) 

0.18” 
(4.6mm) 

Mounting Structure 

Module 

0.62” 
(16mm) 

0.43” 
(11mm) 

0.2” (5mm) 

0.12”  
(3mm) 

0.2”  
(5mm) 

0.2”  
(5mm) 

0.2”  
(5mm) 

1.5” 
(38mm) 

Summary of Contents for HIT Power 240S Series

Page 1: ...O is part of the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT Model No HIT Power 240S VBHN240SA11 and 11B HIT Power 235S VBHN235SA11 and 11B HIT Power 230S VBHN230SA11 and 11B Contents Please read before installation Safety Precautions General Information 3 Warning 3 Cautions 3 General Safety 3 UL Listing Information 3 Installation General 4 Notes on Installation...

Page 2: ...2013 4 19 2nd Edition 2015 3 18 1 System Fire Class Rating 2 Trademark 3 Front cover Grounding 1 Addition of System Fire Class Rating 2 Explanation of trademark 3 According to UL1703 Edition 3 Revision date 2014 11 18 3rd Edition 2015 9 29 Warning Addition of Warning ...

Page 3: ...ases or vapors are present Never rest or leave a module unsupported or unsecured Do not drop modules Do not use or install broken modules Do not artificially concentrate sunlight on a module Do not touch the junction box terminals Do not change the wiring of bypass diodes Do not touch a module unnecessarily The glass surface and frames get hot There is a risk of burn CAUTIONS Use a module for its ...

Page 4: ...of 1 inch clearance between the roof surface and the modules so that air can circulate Panasonic recommends the installation method and mounting profile shown in Figure 1 A module should be attached on a mount or support structure rail by corrosive resistant metal clamps The clamps should be made of aluminum alloy or other material that will reasonably protect against a risk of electrolytic corros...

Page 5: ...2 50PSF in a static state on the module surface Note This mechanical loading value was tested using the mounting device specified in section Notes on Installation WIRING General All wiring should be done in accordance with applicable electrical codes Wiring methods should be in accordance with the NEC in USA or CEC in Canada A qualified licensed professional should do all wiring Wiring should be p...

Page 6: ... clips can be used to ground Panasonic PV modules Both methods are explained below please choose one Grounding Locations or grounding holes Using a self tapping machine screw see Figures 3 2 and 3 4 If using this method use one of the smaller holes with diameter of 0 165 4 2 mm The self tapping machine screw size must be No 10 0 190 diameter 4 83mm This method requires a minimum number of threads ...

Page 7: ... thread contact Note Self tapping machine screws are also called thread cutting screws As shown in figure 3 4 attach grounding lug to module frame using a stainless steel self tapping machine screw Insert a stainless steel star washer between the module frame and the lug to penetrate frame anodization Tighten stainless steel set screw at the torque specified by lug manufacturer to secure copper wi...

Page 8: ...rotection for the systems within the specified system voltage so that you do not need any other additional bypass diodes Contact your Panasonic Authorized Representative for proper diode type if it is necessary to add or change diodes due to system specifications MAINTENANCE Some maintenance is recommended to maintain optimal output performance of the solar modules If the module surface becomes di...

Page 9: ...e frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat washer Stainless steel Spring washe...

Page 10: ...meter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw Stainless screw Star washer Stainless steel Length not less than 0 63 16 mm not more than 0 78 20 mm Self tapping machine screw Stainless steel Copper wire Frame Longer side Glass Backsheet Grounding ...

Page 11: ...ound holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel Nut Stainless steel Copper wire Length not less than 0 63 16 mm not more than 0 78 20 mm Copper wire Frame Longer side Glass Backsheet Grounding hole 0 165 diameter 4 2mm Grounding Clip Self tapping...

Page 12: ... System Voltage Voc 600 600 600 Factory Installed Bypass Diodes 3 3 3 Maximum series fuse A 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds 35 1 4 15 33 1 Electrical Specifications 1580 62 2 798 31 4 SPECIFICATIONS Figure 2 Dimensions Dimensions All HIT Power S Models VBHNxxxSA11VBHNxxxSA11 Note A module should be installed on a mounting s...