Module Terminations 
A junction box as a terminal enclosure is 
equipped for electrical connections.   
VBHNxxxSA11 

and 

VBHNxxxSA11B 

Modules are equipped with MC

TM

 plugs 

as a terminal enclosure. Use these MC

TM

 

plugs  for  electrical  connections

 

(see 

Figure 4.1).   
 
Junction Box and Terminals 

 

Modules  are  equipped  with  one 
junction box containing terminals for 
both,  positive  and  negative  polarity, 
and bypass diodes. 

 

Each  terminal  is  dedicated  to  one  
polarity  with  the  polarity  symbols 
engraved  onto  the  body  of  the 
junction box (see Figure 4.2). 

 

Each  terminal  is  provided  with 
factory  installed  lead  cables  and  a 
latching  connector  for  series  and 
string connections. Always use these 
connectors  and  do  not  detach  them 
from cables. 

 

Latching connectors  are  type  IV  and 
made  by  Multi-Contact.  Supplied 
connectors listed by UL. 

 

In order to comply with NEC 2008, a 
locking sleeve needs to be used with 
all connectors that are exposed. 

 

The locking sleeve (PV-SSH4) is made 
by  Multi-Contact  and  can  only  be 
released  with  a  special  tool  also 
made 

by  Multicontact 

(PV-MS). 

Locking  sleeves  are  not  supplied 
with 

modules 

and 

must 

be 

purchased separately. 

 
Conduit 

 

In  applications  where  wire  raceways 
or  conduit  are  used,  follow  the 
applicable 

codes 

for 

outdoor 

installations..  

 

Verify  that  all  fittings  are  properly 
installed  to  protect  wires  against 
damage 

and 

prevent 

moisture 

intrusion.  

 

DIODES 

Bypass Diodes 

 

When  modules  in  series  strings  are 
partially 

shaded, 

it 

may 

cause 

reverse 

voltage 

across 

cells 

or 

modules,  because  the  current  from 
other  cells  in  the  same  series  is 
forced  to  flow  through  the  shaded 
area.  This  may  cause  undesirable 
heating to occur.  

 

The  use  of  a  diode  to  bypass  the 
shaded  area  can  minimize  both 
heating and array current reduction. 

 

Modules  are  equipped  with  factory 
installed  bypass  diodes.  The  factory-
installed 

diodes 

provide 

proper 

circuit  protection  for  the  systems 
within  the  specified  system  voltage, 
so  that  you  do  not  need  any  other 
additional bypass diodes.  

 

Contact  your  Panasonic  Authorized 
Representative  for  proper  diode 
type,  if  it  is  necessary  to  add  or 
change 

diodes 

due 

to 

system 

specifications. 

 

MAINTENANCE 

 

Some  maintenance  is  recommended 
to 

maintain 

optimal 

output 

performance of the solar modules.  

 

If the module surface becomes dirty, 
it may reduce output power.  

 

It  is  recommended  to  clean  the 
surface  of  the  module  with  water 
and  a  soft  cloth  or  sponge, twice  or 
more per year.  

 
 
 
 

 

A  mild  non-abrasive  detergent  may 
be applied for persistent dirt.   

 

It  is  also  recommended  to  inspect 
the 

electrical 

and 

mechanical 

connections annually. 

 

If  you  need  electrical  or  mechanical 
inspection  or  maintenance,  it  is 
recommended  to  have  a  licensed 
authorized  professional  carry  out 
the  inspection  or  maintenance  to 
avoid  the  hazards  of  electric  shock 
or injury. 

 

Disclaimer of Liability 

 

Panasonic 

does 

not 

assume 

responsibility  and  expressly  disclaims 
liability for loss, damage, or expense 
arising  out  of,  or  in  any  way 
connected 

with 

installation, 

operation,  use,  or  maintenance  by 
using this manual.   

 

Panasonic  assumes  no  responsibility 
for  any  infringement  of  patents  or 
other  rights  of  third  parties,  which 
may result from use of modules.  

 

No  license  is  granted  by  implication 
or under any patent or patent rights. 
The  information  in  this  manual  is 
believed to be reliable, but does not 
constitute 

an 

expressed 

and/or 

implied warranty.  

 

The  return  of  any  modules  will  not 
be  accepted  by  Panasonic  unless 
prior written authorization has been 
given by Panasonic. 

 

As  part  of  Panasonic’s  policy  of 
continuous  improvement,  Panasonic 
reserves the right to change product 
specifications  at  any  time  without 
prior notice.  

 

Customer Services 

 

For  further  information,  please  visit 
http://panasonic.net/energy/solar/ 
or 

contact 

your 

Panasonic 

Authorized Representative. 

Figure 4.2  Junction Box  

Cable 

Negative ( - ) 

Positive ( + ) 

Figure 4.1 Connectors 

Option:  
Safety 

lock 

clip 

Connector 
MC

 TM 

Plug 

Cable 

Negative ( - ) 

Positive ( + ) 

Summary of Contents for HIT Power 240S Series

Page 1: ...O is part of the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT Model No HIT Power 240S VBHN240SA11 and 11B HIT Power 235S VBHN235SA11 and 11B HIT Power 230S VBHN230SA11 and 11B Contents Please read before installation Safety Precautions General Information 3 Warning 3 Cautions 3 General Safety 3 UL Listing Information 3 Installation General 4 Notes on Installation...

Page 2: ...2013 4 19 2nd Edition 2015 3 18 1 System Fire Class Rating 2 Trademark 3 Front cover Grounding 1 Addition of System Fire Class Rating 2 Explanation of trademark 3 According to UL1703 Edition 3 Revision date 2014 11 18 3rd Edition 2015 9 29 Warning Addition of Warning ...

Page 3: ...ases or vapors are present Never rest or leave a module unsupported or unsecured Do not drop modules Do not use or install broken modules Do not artificially concentrate sunlight on a module Do not touch the junction box terminals Do not change the wiring of bypass diodes Do not touch a module unnecessarily The glass surface and frames get hot There is a risk of burn CAUTIONS Use a module for its ...

Page 4: ...of 1 inch clearance between the roof surface and the modules so that air can circulate Panasonic recommends the installation method and mounting profile shown in Figure 1 A module should be attached on a mount or support structure rail by corrosive resistant metal clamps The clamps should be made of aluminum alloy or other material that will reasonably protect against a risk of electrolytic corros...

Page 5: ...2 50PSF in a static state on the module surface Note This mechanical loading value was tested using the mounting device specified in section Notes on Installation WIRING General All wiring should be done in accordance with applicable electrical codes Wiring methods should be in accordance with the NEC in USA or CEC in Canada A qualified licensed professional should do all wiring Wiring should be p...

Page 6: ... clips can be used to ground Panasonic PV modules Both methods are explained below please choose one Grounding Locations or grounding holes Using a self tapping machine screw see Figures 3 2 and 3 4 If using this method use one of the smaller holes with diameter of 0 165 4 2 mm The self tapping machine screw size must be No 10 0 190 diameter 4 83mm This method requires a minimum number of threads ...

Page 7: ... thread contact Note Self tapping machine screws are also called thread cutting screws As shown in figure 3 4 attach grounding lug to module frame using a stainless steel self tapping machine screw Insert a stainless steel star washer between the module frame and the lug to penetrate frame anodization Tighten stainless steel set screw at the torque specified by lug manufacturer to secure copper wi...

Page 8: ...rotection for the systems within the specified system voltage so that you do not need any other additional bypass diodes Contact your Panasonic Authorized Representative for proper diode type if it is necessary to add or change diodes due to system specifications MAINTENANCE Some maintenance is recommended to maintain optimal output performance of the solar modules If the module surface becomes di...

Page 9: ...e frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat washer Stainless steel Spring washe...

Page 10: ...meter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw Stainless screw Star washer Stainless steel Length not less than 0 63 16 mm not more than 0 78 20 mm Self tapping machine screw Stainless steel Copper wire Frame Longer side Glass Backsheet Grounding ...

Page 11: ...ound holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel Nut Stainless steel Copper wire Length not less than 0 63 16 mm not more than 0 78 20 mm Copper wire Frame Longer side Glass Backsheet Grounding hole 0 165 diameter 4 2mm Grounding Clip Self tapping...

Page 12: ... System Voltage Voc 600 600 600 Factory Installed Bypass Diodes 3 3 3 Maximum series fuse A 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds 35 1 4 15 33 1 Electrical Specifications 1580 62 2 798 31 4 SPECIFICATIONS Figure 2 Dimensions Dimensions All HIT Power S Models VBHNxxxSA11VBHNxxxSA11 Note A module should be installed on a mounting s...

Reviews: