background image

Summary of Contents for HEE210U Series

Page 1: ......

Page 2: ......

Page 3: ...e Temperature 10 Power Curve 11 JUNCTION BOX 12 Diode characteristics 12 WARNINGS AND ELECTRICAL RISKS 13 CONNECTION LIMIT OF THE MODULES 14 Module wirings 14 RECOMMENDATIONS FOR THE INSTALLATION 15 Shading 15 Ventilation 15 Installation Requirements 16 Grounding 16 INSTALLATION INSTRUCTIONS 17 INSTRUCTIONS DE MONTAGE 18 TRANSPORT STORAGE UNPACKING AND IDENTIFICATION 19 Storage of Pallets of Modul...

Page 4: ...M HEE275U OR HEE300M HELIOS ENERGY EUROPE S L HELIENE INC AND HELIOS USA LLC DISCLAIM ANY LIABILITY FOR BREAKAGE DETERIORATION OR THE LOSS OF PERFORMANCE OF ANY OF ITS MODULES RESULTING FROM THE INCORRECT USE MAINTENANCE AND OR INSTALLATION THE JUNCTION BOX HAS A LEVEL OF PROTECTION OF IP65 AGAINST INFILTRATION OF DUST AND OR WATER THIS JUNCTION BOX HOUSES THE CONNECTION OF THE METALLIC CELL CONNE...

Page 5: ... 2 FEB 22 FIGURE 1 CROSS SECTION OF A MODULE IDENTIFYING DIFFERENT COMPONENTS ALUMINIUM FRAME ENCAPSULANT TABS PHOTOVOLTAIC CELL TEMPERED GLASS CELLS CONNECTION BACKSHEET BY PASS DIODE JUNCTION BOX GROUNDING TERMINAL HOLE WATER EVACUATION HOLE ...

Page 6: ...IT VOLTAGE AND SHORT CIRCUIT CURRENT OF ANY INDIVIDUAL MODULE WILL BE 3WP OF THESE VALUES SPECIFICATIONS ARE SUBJECT TO CHANGE LES TOLERANCES ACCEPTEES ENTRE CHAQUE MODULE ET LA VALEUR DE REFERENCE SONT DE 3WP POUR LES DONNEES DE PUISSANCE MAXIMALE TENSION DE CIRCUIT OUVERT ET COURANT DE COURT CIRCUIT ...

Page 7: ...IT VOLTAGE AND SHORT CIRCUIT CURRENT OF ANY INDIVIDUAL MODULE WILL BE 3WP OF THESE VALUES SPECIFICATIONS ARE SUBJECT TO CHANGE LES TOLERANCES ACCEPTEES ENTRE CHAQUE MODULE ET LA VALEUR DE REFERENCE SONT DE 3WP POUR LES DONNEES DE PUISSANCE MAXIMALE TENSION DE CIRCUIT OUVERT ET COURANT DE COURT CIRCUIT ...

Page 8: ...UIT VOLTAGE AND SHORT CIRCUIT CURRENT OF ANY INDIVIDUAL MODULE WILL BE 4WP OF THESE VALUES SPECIFICATIONS ARE SUBJECT TO CHANGE LES TOLERANCES ACCEPTEES ENTRE CHAQUE MODULE ET LA VALEUR DE REFERENCE SONT DE 4WP POUR LES DONNEES DE PUISSANCE MAXIMALE TENSION DE CIRCUIT OUVERT ET COURANT DE COURT CIRCUIT ...

Page 9: ...UIT VOLTAGE AND SHORT CIRCUIT CURRENT OF ANY INDIVIDUAL MODULE WILL BE 4WP OF THESE VALUES SPECIFICATIONS ARE SUBJECT TO CHANGE LES TOLERANCES ACCEPTEES ENTRE CHAQUE MODULE ET LA VALEUR DE REFERENCE SONT DE 4WP POUR LES DONNEES DE PUISSANCE MAXIMALE TENSION DE CIRCUIT OUVERT ET COURANT DE COURT CIRCUIT ...

Page 10: ...TERS FOR THE CELLS WILL BE RELATED TO THE VARIATION OF SUN LIGHT RADIATION RECEIVED AND THE ACTUAL WEATHER CONDITIONS TEMPERATURE THESE PARAMETERS SHOW THE INDICATED VALUES IN THE PREVIOUS CHARTS THE VARIATIONS OF THE WORKING POINT OF THE MODEL ACCORDING TO DIFFERENT OPERATION PARAMETERS ARE SHOWN IN THE GRAPHS ON THE NEXT PAGE ...

Page 11: ...NT VOLTAGE CURVES VARIATION DUE TO SOLAR RADIANCE TEMPERATURE FIGURE 2 VARIATION OF THE CURVE CURRENT VOLTAGE ACCORDING TO THE INCIDENTAL SOLAR RADIANCE TO A CELL TEMPERATURE OF 25 ºC FIGURE 3 VARIATION OF THE CURVE OF CURRENT VOLTAGE ACCORDING TO THE TEMPERATURE OF THE CELL ...

Page 12: ...NT VOLTAGE CURVES VARIATION DUE TO SOLAR RADIANCE TEMPERATURE FIGURE 2 VARIATION OF THE CURVE CURRENT VOLTAGE ACCORDING TO THE INCIDENTAL SOLAR RADIANCE TO A CELL TEMPERATURE OF 25 ºC FIGURE 3 VARIATION OF THE CURVE OF CURRENT VOLTAGE ACCORDING TO THE TEMPERATURE OF THE CELL ...

Page 13: ...HE WORKING POINT THE ABOVE FIGURE SHOWS THAT THERE IS A POINT FOR WHICH THE PRODUCT I X V REACHES ITS MAXIMUM THIS POINT CALLED THE MAXIMUM POWER POINT DETERMINES THE PEAK POWER USING THE UNITS WP THE ABILITY OF THE SYSTEM TO TRACE THIS POINT IN RELATION TO THE WORKING CONDITIONS VARIATION IS CALLED TRACKING OF THE MAXIMUM POTENTIAL POINT TPMP ...

Page 14: ... RESULTING FROM THE PROJECTION OF ANY OBJECT OR FROM THE ACCUMULATION OF DIRT OR DEBRIS THE REVERSE POLARIZATION OF A CELL CAN LEAD TO CONSUMPTION OF ENERGY PRODUCED BY THE REST OF THE SYSTEM THE DISSIPATION OF THIS ENERGY CAN LEAD TO DANGEROUS OVERHEATING AND AFFECT THE CELL DAMAGE CAN INCLUDE BUT NOT BE LIMITED TO THE RELEASE OF ITS ANTI REFLECTION CAP THE PERFORATION OF THE P N JUNCTION OR EVEN...

Page 15: ...ALREADY CONTAINS ALL THE NECESSARY WIRING FOR ITS CONNECTION SO THE JUNCTION BOX MUST NOT BE INTERFERED WITH DURING ITS INSTALLATION THE PHOTOVOLTAIC SOLAR MODULE HAS BEEN DESIGNED TO WORK WITH LEVELS OF INCIDENTAL SOLAR RADIATION NORMALLY FOUND ON THE EARTH S SURFACE DO NOT CONCENTRATE THE RADIATION WITHOUT THE EXPRESS CONSENT OF AUTHORIZED PERSONNEL THIS CONCENTRATION CAN PRODUCE MALFUNCTIONS AN...

Page 16: ...OF 40ºC HOWEVER THERE IS NO LIMIT AS TO THE CONNECTION OF MODULES IN PARALLEL AS THE OPERATION OF ONE DOES NOT AFFECT THE OTHERS EXCEPT FOR THE LIMITATION THAT THEY MUST ALL WORK AT THE SAME VOLTAGE LEVEL THEREFORE ALL THE MODULES CONNECTED IN PARALLEL MUST HAVE AN EQUAL NUMBER OF CELLS IN THIS WAY AVOIDING THE RECIRCULATION OF CURRENT BETWEEN ROWS OF MODULES IN CASE OF A PARALLEL CONNECTION THE N...

Page 17: ...CIPITATION THE TILT OF THE MODULES SHOULD BE AT LEAST 20 EACH MODULE SHOULD BE SITUATED WITH AT LEAST 15 CENTIMETRES 6 INCHES OF OPEN SPACE BEHIND IT TO ENSURE THAT THE VENTILATION DISSIPATES THE HEAT PRODUCED BY THE CELLS AND THAT THE LOSSES FROM THIS EFFECT ARE MINIMAL IF THE MODULES ARE INSTALLED ONE BESIDE THE OTHER THE HEIGHT OF THE HARDWARE SHOULD BE LEVELLED TO AVOID THE PROJECTION OF SHADO...

Page 18: ...S TO THE GROUND A UL LISTED GROUNDING LUG SHOULD BE USED ENSURE COMPLIANCE WITH ALL LOCAL ELECTRICAL CODES AND REGULATIONS SEVERAL DIFFERENT METHODS OF GROUNDING CAN BE USED TO PROVIDE THE REQUIRED CONNECTION THROUGH THE ANODIZED FRAME THE FOLLOWING METHODS OF PERFORMING THIS TASK ARE ACCEPTABLE A UL LISTED GROUNDING LUG MAY BE USED THE EXISTING GROUNDING HOLES IN THE MODULE FRAMES SHOULD BE USED ...

Page 19: ...AN 6MM OVERLAP IF THE CLAMPS ARE BEING USED TO SUPPORT TWO MODULES AT CORNER OF EACH IT MUST HAVE A MINIMUM OF 25MM ON EACH MODULE FRAME SURFACE AND BE A MINIMUM OF 57MM 3 IF CLAMPS ARE SUPPORTING A SINGLE MODULE THERE MUST BE A MINIMUM LENGTH OF 25MM OF CLAMPED SURFACE PER MODULE ENSURE TO COMPLY WITH ALL LOCAL BUILDING CODES HELIENE MODULES COULD BE MOUNTED ON A ROOF FREESTANDING MODULES TURN A ...

Page 20: ... HELIENE PEUVENT ETRE MONTES EN TOITURE LA PRESENCE DE MODULES SOLAIRES EN MONTAGE SURIMPOSE FAIT LA PASSER UN TOIT DE CLASSE B A UN TOIT DE CLASSE C IL EST NECESSAIRE D UTILISER DES MATERIAUX ET EQUIPEMENTS DE MONTAGE ET SERRAGE AYANT LES PROPRIETES D ANTI CORROSION APPROPIES LE MODE DE FIXATION HAUT ET BAS DES MODULES VARIE EN FONCTION DE LA STRUCTURE DE MONTAGE UTILISEE IL EST NECESSAIRE DE SUI...

Page 21: ...F MODULES DO NOT TRANSPORT MODULES IN AN UPRIGHT POSITION ONLY TRANSPORT THEM IN BOX STRAPPED TO PALLET AS SUPPLIED BY HELIENE INC ON A LEVEL SURFACE STACK ONLY 2 BOXES PALLETS HIGH AT MAXIMUM AND NEVER PLACE OTHER MATERIAL ON TOP OF THEM LOAD AND UNLOAD WITH A FORKLIFT AVOIDING HITTING BANGING DROPPING OR DAMAGE TO THE BOXES UNPACKING HANDLING OF MODULES BEFORE UNPACKING HAVE MODULE BOX IN A LEVE...

Page 22: ...KEN DO NOT SET THE MODULES ONTO SURFACES SMALLER THAN THE MODULE PERIMETER SIZE AS MODULE WEIGHT MUST SIT ON THE ALUMINUM FRAME ONLY IDENTIFICATION EACH MODULE IS IDENTIFIED IN 3 LOCATIONS 2 SERIAL NUMBERS WITH ITS RESPECTIVE BAR CODES ONE ON THE SHORT FRAME SIDE AND ONE ON THE INSIDE OF THE JUNCTION BOX THE THIRD IDENTIFICATION IS THE NAMEPLATE LABEL WITH MODEL TYPE ELECTRICAL CHARACTERISTICS DAT...

Page 23: ...OF AGING OR CORROSION IN THIS INSPECTION SPECIAL ATTENTION SHOULD BE GIVEN TO THE INTEGRITY OF THE GLASS THE ALUMINIUM FRAME THE SILICONE SEALS THE WATERPROOF OF THE JUNCTION BOX OXIDATION OF THE CONTACTS BETWEEN CELLS AND CONDENSATION IN THE INTERIOR OF THE LAMINATE THESE TASKS SHOULD BE DONE AT LEAST ONCE A YEAR BY QUALIFIED PERSONNEL TESTING OF THE WIRING AND THE CONNECTIONS AT LEAST ONCE A YEA...

Page 24: ...ARENCY OF THE MODULE ACCUMULATION OF DIRT AND HUMIDITY BETWEEN THE SPOTS MIGHT LEAD TO FREEZING INCREASING THE SEPARATION OF THE FRAME LOSS OF SEAL OF THE JUNCTION BOX A LOSS OF THE JUNCTION BOX SEAL WILL ALLOW HUMIDITY IN POSSIBLE CAUSING CORROSION AND A BAD ELECTRICAL FUNCTIONING SHORT CIRCUIT OF THE MODULE AN EXCESS OF INTENSITY DUE TO METEOROLOGICAL PHENOMENA OR MISTAKES IN THE CONNECTION CAN ...

Page 25: ...N UL 2 2 FEB 22 MODULE VIEWS WITH DIMENSIONS HELIENE MODULES ARE ASSEMBLED WITH THE SAME TYPE GLASS AND ALUMINIUM FRAME THEREFORE THEY SHARE THE SAME DIMENSIONS FOR PAIRINGS OF HEE210U HEE215 HEE257U HEE300M HEE210U HEE215M HEE275U HEE300M ...

Page 26: ...ENE GUARANTEE FACTORY CERTIFICATE TÜV NORD INTERTEK MONO CRYSTALLINE MODULES IEC 61625 IEC 61730 TÜV NORD CERTIFICATE MULTI CRYSTALLINE MODULES IEC 61625 IEC 61730 TÜV NORD CERTIFICATE CERTIFICATE ULC ORD C1703 01 BY INTERTEK CETLUS MARK WITH LISTED NUMBERS BADALONA SPAIN 4001272 SAULT STE MARIE CANADA 4002316 CEC LISTED ...

Reviews: