background image

 

 

AFL3-W15C/W19C/W22C-ULT5 Panel PC 

Page I

 

 

User Manual 

AFL3-W15C/W19C/W22C-ULT5 

MODEL: 

Flat Bezel Panel PC with Intel® Core™ i5-8365UE CPU, 

Touchscreen, Four USB 3.2 Gen 2, Dual PoE GbE LAN, 

RS-232/422/485, Bluetooth, Wi-Fi 802.11a/b/g/n/ac and RoHS 

 

 

Rev. 1.00 - February 6, 2020 

User Manual 

Summary of Contents for AFL3-W15C-ULT5-P-PC-4G

Page 1: ...I User Manual AFL3 W15C W19C W22C ULT5 MODEL Flat Bezel Panel PC with Intel Core i5 8365UE CPU Touchscreen Four USB 3 2 Gen 2 Dual PoE GbE LAN RS 232 422 485 Bluetooth Wi Fi 802 11a b g n ac and RoHS...

Page 2: ...AFL3 W15C W19C W22C ULT5 Panel PC Page II Revision Date Version Changes February 6 2020 1 00 Initial release...

Page 3: ...overheating do not operate it in an area that exceeds the maximum operating temperature described in the user manual Vorsicht Um eine berhitzung des Systems zu vermeiden betreiben Sie es ausschlie li...

Page 4: ...L uso di un altro tipo di adattatore pu causare rischio d incendio o esplosione Si prega di fare riferimento al manuale utente per le specifiche sull alimentazione Atenci n Utilice solamente el adapt...

Page 5: ...mages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright A...

Page 6: ...CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but non critical information These mess...

Page 7: ...ions 11 1 9 3 AFL3 W22C ULT5 Dimensions 12 2 UNPACKING 13 2 1 UNPACKING 14 2 2 PACKING LIST 14 2 3 OPTIONAL ITEMS 15 3 INSTALLATION 18 3 1 ANTI STATIC PRECAUTIONS 19 3 2 INSTALLATION PRECAUTIONS 19 3...

Page 8: ...51 3 16 SOFTWARE INSTALLATION 51 3 16 1 Driver Download 52 4 BIOS SETUP 54 4 1 INTRODUCTION 55 4 1 1 Starting Setup 55 4 1 2 Using Setup 55 4 1 3 Getting Help 56 4 1 4 Unable to Reboot after Configur...

Page 9: ...4 6 BOOT 83 4 7 EXIT 85 5 SYSTEM MAINTENANCE 87 5 1 SYSTEM MAINTENANCE INTRODUCTION 88 5 2 ANTI STATIC PRECAUTIONS 88 5 3 TURN OFF THE POWER 89 5 4 SO DIMM MODULE REPLACEMENT 89 6 INTERFACE CONNECTOR...

Page 10: ...MI1 104 6 3 3 RS 232 422 485 DB 9 Serial Port COM1 104 6 3 4 RS 232 RJ 45 Serial Port COM2 105 6 3 5 USB 3 2 Gen 2 Connectors USB_CON1 105 A REGULATORY COMPLIANCE 106 B SAFETY PRECAUTIONS 112 B 1 SAFE...

Page 11: ...Retention Screws 23 Figure 3 6 AFL3 W22C ULT5 Metal Cover Retention Screws 23 Figure 3 7 Lift the Metal Cover 24 Figure 3 8 M 2 Module Slot Location 25 Figure 3 9 Inserting the M 2 Module into the Sl...

Page 12: ...curing Panel Mounting Brackets 43 Figure 3 31 Rack Mounting Kit Installation 45 Figure 3 32 Securing Rack Mounting Brackets 46 Figure 3 33 Install into a Rack Cabinet 46 Figure 3 34 Arm Mounting Reten...

Page 13: ...8 M 2 M key Slot M2_M2 Pinouts 98 Table 6 9 Microphone Connector DMIC1 Pinouts 98 Table 6 10 Full size PCIe Mini Connector MINI_PCIE1 Pinouts 99 Table 6 11 Power Button Connector PW_BTN1 Pinouts 100...

Page 14: ...AFL3 W15C W19C W22C ULT5 Panel PC Page XIV Table 6 26 USB 3 2 Gen 2 Connectors USB_CON1 USB_CON2 Pinouts 105...

Page 15: ...10 Serial Port Console Redirection 67 BIOS Menu 11 Legacy Console Redirection Settings 68 BIOS Menu 12 Console Redirection Settings 69 BIOS Menu 13 USB Configuration 71 BIOS Menu 14 NVMe Configuration...

Page 16: ......

Page 17: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 1 1 Introduction Chapter 1...

Page 18: ...m on Chip SoC that ensures optimal memory graphics and peripheral I O support The system comes with 4 0 GB of DDR4 SO DIMM memory ensuring smooth data throughputs with reduced bottlenecks and fast sys...

Page 19: ...ULT5 features are listed below Flat bezel LCD with LED backlight 8th generation Intel Core i5 8365UE processor Preinstalled with 4 GB of DDR4 memory system max 32 GB Anti glare anti UV projected capac...

Page 20: ...d by a PC ABS plastic frame Figure 1 2 Figure 1 2 Front View There is a power LED indicator located on the front panel The status descriptions of the power LED indicator are listed below Off power cor...

Page 21: ...owing connectors and switches Figure 1 3 Bottom Panel 1 6 Rear Panel The rear panel has two speakers and retention screw holes that support VESA mounting The rear panel also has several retention scre...

Page 22: ...rder only Part No Description Supported Model E MPCIE LAN PCIe Mini card supports one GbE port with Realtek RTL8111E controller PMS 194C I O bracket and 250 mm cable AFL3 W15C ULT5 E MPCIE LAN02 PCIe...

Page 23: ...30 000 hrs Backlight LED LED LED Touchscreen Anti glare Anti UV projected capacitive Anti glare Anti UV projected capacitive Anti glare Anti UV projected capacitive Touch Controller EETI EXC 3160 EETI...

Page 24: ...aterial PC ABS plastic Thermal Design Fanless VESA Mount 75 mm x 75 mm 100 mm x 100 mm Mounting Panel wall stand or arm mounting Front Panel Color Black C Net Gross Weight 4 5 kg 6 5 kg 7 3 kg 10 kg 8...

Page 25: ...PoE GbE LAN RJ 45 connector 1 x GbE LAN RJ 45 connector 4 x USB 3 2 Gen 2 10 Gb s connectors 1 x HDMI output connector 1 x Power button 1 x AT ATX switch 1 x Reset button 1 x Clear CMOS button 1 x 12...

Page 26: ...22C ULT5 Panel PC Page 10 1 9 Dimensions The following sections list the dimensions of each model 1 9 1 AFL3 W15C ULT5 Dimensions The AFL3 W15C ULT5 dimensions are shown below Figure 1 6 AFL3 W15C ULT...

Page 27: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 11 1 9 2 AFL3 W19C ULT5 Dimensions The AFL3 W19C ULT5 dimensions are shown below Figure 1 7 AFL3 W19C ULT5 Dimensions mm...

Page 28: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 12 1 9 3 AFL3 W22C ULT5 Dimensions The AFL3 W22C ULT5 dimensions are shown below Figure 1 8 AFL3 W22C ULT5 Dimensions mm...

Page 29: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 13 2 Unpacking Chapter 2...

Page 30: ...the box Only cut deep enough to break the tape Step 2 Open the outside box Step 3 Carefully cut the tape sealing the box Only cut deep enough to break the tape Step 4 Open the inside box Step 5 Lift...

Page 31: ...FL3 W15C W19C W22C ULT5 panel PC 1 96 W power adapter 1 Power cord 4 Screws M4 6 for VESA mounting 4 Screws M3 4 for HDD installation 2 3 Optional Items The following are optional components which may...

Page 32: ...t Number Image VESA 100 wall mount kit P N AFLWK 19B Panel mounting kit P N AFL3PK W15A R10 for W15C P N AFL3PK W19C R10 for W19C W22C Rack mounting kit P N AFL3RK W15B R10 for W15C Arm P N ARM 11 RS...

Page 33: ...and Part Number Image Stand for VESA 75 VESA 100 P N STAND C19 R10 Magnetic card reader P N AFL3P W10MSR U R10 Barcode scanner P N AFL3 2D R11 If any of these items are missing or damaged contact the...

Page 34: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 18 3 Installation Chapter 3...

Page 35: ...band can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conductin...

Page 36: ...2 Install an M 2 SSD or a HDD Step 3 Configure the system Step 4 Connect peripheral devices to the flat bezel panel PC Step 5 Mount the flat bezel panel PC Step 0 3 4 Removing the Back Covers To acces...

Page 37: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 21 Figure 3 1 AFL3 W15C ULT5 Back Cover Retention Screws Figure 3 2 AFL3 W19C ULT5 Back Cover Retention Screws...

Page 38: ...he AFL3 W15C W19C W22C ULT5 Step 3 Remove the retention screws from the internal metal cover Two types of screw are used for securing the metal cover See the following diagrams for detail Be aware of...

Page 39: ...3 W15C W19C W22C ULT5 Panel PC Page 23 Figure 3 4 AFL3 W15C ULT5 Metal Cover Retention Screws Figure 3 5 AFL3 W19C ULT5 Metal Cover Retention Screws Figure 3 6 AFL3 W22C ULT5 Metal Cover Retention Scr...

Page 40: ...ver off the AFL3 W15C W19C W22C ULT5 A thermal pad is attached under the center of the metal cover To easily remove the cover turn the cover in a clockwise direction first to detach the thermal pad be...

Page 41: ...ULT5 please follow the steps below Step 1 Remove the plastic back cover and the internal metal cover See Section 3 4 above Step 2 Locate the M 2 slot Remove the preinstalled retention screw on the mot...

Page 42: ...9C W22C ULT5 Panel PC Page 26 Figure 3 9 Inserting the M 2 Module into the Slot at an Angle Step 4 Secure the M 2 module with the previously removed retention screw Figure 3 10 Figure 3 10 Securing th...

Page 43: ...LT5 please follow the steps below Step 1 Remove the plastic back cover and the internal metal cover See Section 3 4 above Step 2 Locate the PCIe Mini module slot Remove the preinstalled retention scre...

Page 44: ...th the notch on the connector Slide the PCIe Mini card into the socket at an angle of about 20 Figure 3 13 Figure 3 13 Installing a PCIe Mini Module Step 5 Secure the PCIe Mini module with the retenti...

Page 45: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 29 Figure 3 14 Securing the PCIe Mini Module Step 6 Re install the metal cover and the plastic back cover Step 0...

Page 46: ...Section 3 4 above Step 2 Remove the four HDD bracket retention screws and lift the HDD bracket off the panel PC Figure 3 15 HDD Bracket Retention Screws Step 3 Attach the HDD brackets to the HDD To d...

Page 47: ...DD from the motherboard Step 5 Install the HDD into the AFL3 W15C W19C W22C ULT5 by aligning the retention screw holes in the HDD brackets with the retention screw holes on the chassis Insert the four...

Page 48: ...cover and the internal metal cover See Section 3 4 above Step 2 Refer to the following diagram to locate the PoE module slot for installing the PoE module you purchased Figure 3 18 PoE Module Slot Lo...

Page 49: ...The pinouts of COM1 external serial port are detailed below PIN NO RS 232 RS 422 RS 485 1 DCD TXD422 TXD485 2 RXD TXD422 TXD485 3 TXD RXD422 4 DTR RXD422 5 GND 6 DSR 7 RTS 8 CTS 9 RI Table 3 1 RS 232...

Page 50: ...r Location 3 10 Flash Descriptor Security Override The Flash Descriptor Security Override jumper ME_FLASH1 allows to enable or disable the ME firmware update Refer to Figure 3 20 and Table 3 3 for the...

Page 51: ...Step 2 Remove the metal clip on the Flash Descriptor Security Override jumper Step 3 Restart the system The system will reboot 2 3 times to complete the ME firmware update Step 0 3 11 Clear CMOS If t...

Page 52: ...production line to control multiple panel PCs from a central management center and other applications including ATM Self service kiosk Plant environment monitoring system Factory automation platform M...

Page 53: ...o the wall please follow the steps below Step 1 Select the location on the wall for the wall mounting bracket Step 2 Carefully mark the locations of the four screw holes in the bracket on the wall Ste...

Page 54: ...ll mount kit into the four screw holes on the real panel of the flat bezel panel PC and tighten until the screw shank is secured against the rear panel Figure 3 24 WARNING Please use the M4 screws pro...

Page 55: ...gently pull the monitor downwards until the monitor rests securely in the slotted holes Figure 3 24 Ensure that all four of the mounting screws fit snugly into their respective slotted holes NOTE In t...

Page 56: ...he AFL3 W15C W19C W22C ULT5 flat bezel panel PC into a panel please follow the steps below Step 1 Select the position on the panel to mount the panel PC Step 2 Cut out a section corresponding to the s...

Page 57: ...against the panel Step 4 Insert a M5 50 screw into the screw hole on the side of the panel mounting bracket Then install the following components onto the screw in sequence See Figure 3 29 Sequence It...

Page 58: ...kets Figure 3 29 Panel Mounting Kit Installation Step 6 Align the panel mounting bracket screw holes with the VESA mounting holes on the rear of the panel PC Step 7 Secure the two panel mounting brack...

Page 59: ...W19C W22C ULT5 Panel PC Page 43 Figure 3 30 Securing Panel Mounting Brackets NOTE The panel mounting kit described in this section is an optional item To purchase it please contact an IEI sales repre...

Page 60: ...W19C W22C ULT5 is installed Step 1 Slide the rear chassis of the AFL3 W15C W19C W22C ULT5 panel PC through the rack cabinet bracket until the frame is flush against the front of the bracket Step 2 Ins...

Page 61: ...n Step 4 Align the rack mounting bracket screw holes with the VESA mounting holes on the rear of the panel PC Step 5 Secure the two rack mounting brackets to the rear of the panel PC by inserting the...

Page 62: ...C W22C ULT5 Panel PC Page 46 Figure 3 32 Securing Rack Mounting Brackets Step 6 Slide the panel PC with the attached rack cabinet bracket into a rack or cabinet Figure 3 33 Figure 3 33 Install into a...

Page 63: ...he AFL3 W15C W19C W22C ULT5 on an arm please follow the steps below Step 1 The arm is a separately purchased item Please correctly mount the arm onto the surface it uses as a base To do this refer to...

Page 64: ...34 Arm Mounting Retention Screw Holes Step 4 Secure the AFL3 W15C W19C W22C ULT5 to the interface pad by inserting four retention screws through the mounting arm interface pad and into the AFL3 W15C...

Page 65: ...the steps below Step 1 Locate the screw holes on the rear of the AFL3 W15C W19C W22C ULT5 This is where the bracket will be attached Step 2 Align the bracket with the screw holes Step 3 To secure the...

Page 66: ...o the power adapter Connect the other end of the power cord to a power source Step 2 Connect the power adapter to the power connector of the AFL3 W15C W19C W22C ULT5 Step 3 Locate the power button on...

Page 67: ...gure 3 38 Press the reset button to reboot the system Figure 3 38 Reset Button Location 3 16 Software Installation All the drivers for the AFL3 W15C W19C W22C ULT5 are available on IEI Resource Downlo...

Page 68: ...s because there is a HID touch digitizer built in driver in Windows 7 or later 3 16 1 Driver Download To download drivers from IEI Resource Download Center follow the steps below Step 1 Go to https do...

Page 69: ...ile or click the small arrow to find an individual driver and click the file name to download NOTE To install software from the downloaded ISO image file in Windows 8 8 1 or 10 double click the ISO fi...

Page 70: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 54 4 BIOS Setup Chapter 4...

Page 71: ...1 Press the DELETE or F2 key as soon as the system is turned on or 2 Press the DELETE or F2 key when the Press Del to enter SETUP message appears on the screen 0 If the message disappears before the...

Page 72: ...hted item appears To exit the Help Window press ESC or the F1 key again 4 1 4 Unable to Reboot after Configuration Changes If the computer cannot boot after changes to the system configuration is made...

Page 73: ...ed 1800 MHz ID 0x806EC Stepping V0 Number of Processors 4Core s 8Thread s Microcode Revision B8 GT Info GT2 0x3EA0 IGFX VBIOS Version 1017 Memory RC Version 0 7 1 95 Total Memory 4096 MB Memory Freque...

Page 74: ...s below may cause the system to malfunction Make sure that the settings made are compatible with the hardware Aptio Setup Utility Copyright C 2019 American Megatrends Inc Main Advanced Chipset Securit...

Page 75: ...Step tm Enabled C states Disabled Intel Trusted Execution Disabled Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Select Screen Select...

Page 76: ...Enabled Use the Hyper threading BIOS option to enable or disable the Intel Hyper Threading Technology Disabled Disables the Intel Hyper Threading Technology Enabled DEFAULT Enables the Intel Hyper Thr...

Page 77: ...Disabled OEMFlag Bit 15 Unconfigure ME with resetting MEBx password to default Select Screen Select Item EnterSelect F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ESC Exit Version 2...

Page 78: ...SUSPEND button is pressed Select Screen Select Item EnterSelect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Me...

Page 79: ...2 Previous Values F3 Optimized Defaults F4 Save ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 6 RTC Wake Settings Wake system with Fixed Time Disabled Use the Wake syst...

Page 80: ...Advanced PC Health Status CPU temperature 31 C System temperature 29 C VCCCORE 0 756 V VDDQ 1 219 V V3 3S 3 416 V V3 3A 3 416 V V1 05A 1 038 V VCCSA 0 715 V Select Screen Select Item EnterSelect Chan...

Page 81: ...Setup Utility Copyright C 2019 American Megatrends Inc Advanced F81866 Super IO Configuration Super IO Chip F81866 Serial Port 1 Configuration Serial Port 2 Configuration Set Parameters of Serial Port...

Page 82: ...F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 9 Serial Port n Configuration 4 3 6 1 1 Serial Port 1 Co...

Page 83: ...recting keyboard input and text output through the serial port Aptio Setup Utility Copyright C 2019 American Megatrends Inc Advanced COM1 Console Redirection Disabled Console Redirection Settings COM2...

Page 84: ...etup Utility Copyright C 2019 American Megatrends Inc Advanced Legacy Serial Redirection Port COM1 Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages Select Screen Select...

Page 85: ...ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes Select Screen Select Item...

Page 86: ...speed at 115200 Data Bits 8 Use the Data Bits option to specify the number of data bits 7 Sets the data bits at 7 8 DEFAULT Sets the data bits at 8 Parity None Use the Parity option to specify the pa...

Page 87: ...s Aptio Setup Utility Copyright C 2019 American Megatrends Inc Advanced USB Configuration USB Controllers 1 XHCI USB Devices 1 Keyboard 1 Mouse 1 Point Legacy USB Support Enabled Enables Legacy USB su...

Page 88: ...ere is no USB driver loaded onto the system Enabled DEFAULT Legacy USB support enabled Disabled Legacy USB support disabled Auto Legacy USB support disabled if no USB devices are connected 4 3 9 NVMe...

Page 89: ...min when OS crashes Please install Auto Recovery API service before enabling this function Select Screen Select Item EnterSelect F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ESC Ex...

Page 90: ...2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 16 Chipset 4 4 1 System Agent SA Configuration Use the System Agent SA Configuration menu BIOS Menu 17 to configure the System Agent SA par...

Page 91: ...Megatrends Inc Chipset Memory Configuration Memory Frequency 2133 MHz DIMM1 Populated Enabled Size 8192 MB DDR4 Fast Boot Enabled Enable Disable fast path thru the MRC Select Screen Select Item EnterS...

Page 92: ...neral Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 19 Graphics Configuration DVMT Pre Allocated 32M Use the...

Page 93: ...tion menu BIOS Menu 20 to configure the PCH IO chipset Aptio Setup Utility Copyright C 2019 American Megatrends Inc Chipset PCH IO Configuration Auto Power Button Status Disable ATX Restore AC Power L...

Page 94: ...is disabled Enabled Power saving function is enabled It will reduce power consumption when the system is off HD Audio Enabled Use the HD Audio BIOS option to enable or disable the High Definition Audi...

Page 95: ...ge Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 21 PCI Express Configuration The PCIe slot su...

Page 96: ...Menu 22 to change and or set the configuration of the SATA devices installed in the system Aptio Setup Utility Copyright C 2019 American Megatrends Inc Advanced SATA And RST Configuration STAT Contro...

Page 97: ...o set the Option ROM Messages BIOS option in the Boot menu to Force BIOS This is to allow the Press CTRL I to enter Configuration Utility message to appear during POST Press Ctrl I when prompted to en...

Page 98: ...then this is a power on password and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password length must be Minimum length 3 Maximum length 20 Administrato...

Page 99: ...2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 24 Boot Bootup NumLock State On Use the Bootup NumLock State BIOS option to specify if the number lock setting must be modified during boo...

Page 100: ...ed Load PXE Option ROMs Option ROM Messages Force BIOS Use the Option ROM Messages option to set the Option ROM display mode Force BIOS DEFAULT Sets display mode to force BIOS Keep Current Sets displa...

Page 101: ...Item EnterSelect F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc BIOS Menu 25 Exit Save Changes and Reset Use the S...

Page 102: ...PC Page 86 Save as User Defaults Use the Save as User Defaults option to save the changes done so far as user defaults Restore User Defaults Use the Restore User Defaults option to restore the user de...

Page 103: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 87 5 System Maintenance Chapter 5...

Page 104: ...3 W15C W19C W22C ULT5 Dry climates are especially susceptible to ESD It is therefore critical that whenever the AFL3 W15C W19C W22C ULT5 is accessed internally or any other electrical component is han...

Page 105: ...system make sure the system is turned off 5 4 SO DIMM Module Replacement The AFL3 W15C W19C W22C ULT5 has one SO DIMM module installed To replace the SO DIMM module follow the instructions below Step...

Page 106: ...w DDR4 memory module by pushing it into the socket at a 20 angle Figure 5 2 Step 8 Gently push the memory module downwards and the arms clip into place Figure 5 2 Figure 5 2 SO DIMM Installation Step...

Page 107: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 91 6 Interface Connectors Chapter 6...

Page 108: ...mes with a number of peripheral interface connectors and configuration jumpers The connector locations are shown in Figure 6 1 The Pin 1 locations of the on board connectors are also indicated in the...

Page 109: ...connector 12 pin wafer DBG_PORT1 Digital I O connector 10 pin header DIO1 IEI PoE module slots Full size Half size PCIe Mini slot F638_POE1 F639_POE1 Inverter connector 6 pin wafer INVERTER1 LVDS con...

Page 110: ..._R Table 6 2 Audio Out Connector AUDIO_OUT2 Pinouts 6 2 2 Battery Connector BAT1 PIN NO DESCRIPTION 1 VBATT 2 GND Table 6 3 Battery Connector BAT1 Pinouts 6 2 3 Digital I O Connector DIO1 PIN NO DESCR...

Page 111: ...GND 2 GND 3 LVDS_A_TX0 P 4 LVDS_A _TX0 N 5 LVDS_A_TX1 P 6 LVDS_A _TX1 N 7 LVDS_A_TX2 P 8 LVDS_A _TX2 N 9 LVDS_A_TXCLK P 10 LVDS_A _TXCLK N 11 LVDS_A_TX3 P 12 LVDS_A _TX3 N 13 GND 14 GND 15 LVDS_B _TX0...

Page 112: ...ule Key 13 Module Key 14 Module Key 15 Module Key 16 NC 17 NC 18 GND 19 NC 20 NC 21 NC 22 NC 23 GND 24 GND 25 NC 26 NC 27 NC 28 NC 29 GND 30 GND 31 NC 32 NC 33 GND 34 NC 35 PCIE_TX 36 GND 37 PCIE_TX 3...

Page 113: ...7 M 2 M key Slot M2_M2 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 GND 2 3 3VA 3 GND 4 3 3VA 5 PCIE_RX 6 N C 7 PCIE_RX 8 N C 9 GND 10 3 3VA 11 PCIE_TX 12 3 3VA 13 PCIE_TX 14 3 3VA 15 GND 16 3 3VA 17 PCIE_...

Page 114: ...53 CLK_PCIE_M2_M 54 LAN_WAKE 55 CLK_PCIE_M2_M 56 N C 57 GND 58 N C 59 N C 60 N C 61 N C 62 N C 63 N C 64 N C 65 N C 66 N C 67 N C 68 N C 69 M2_IFDET 70 3 3VA 71 GND 72 3 3VA 73 GND 74 3 3VA 75 GND Tab...

Page 115: ...1 CLK 12 N C 13 CLK 14 N C 15 GND 16 N C 17 N C 18 GND 19 N C 20 3 3V 21 GND 22 PCIRST 23 PCIE_RX 24 3VDual 25 PCIE_RX 26 GND 27 GND 28 1 5V 29 GND 30 SMBCLK 31 PCIE_TX 32 SMBDATA 33 PCIE_TX 34 GND 35...

Page 116: ...D Table 6 11 Power Button Connector PW_BTN1 Pinouts 6 2 11 Power LED Connector PW_LED1 PIN NO DESCRIPTION 1 PW_LED 5V 2 GND 3 SUS PW LED 5V Table 6 12 Power LED Connector PW_LED1 Pinouts 6 2 12 SATA C...

Page 117: ..._SO_SW 4 SPI_CLK_SW 5 SPI_SI_SW 6 GND Table 6 14 SPI Flash Connector JSPI1 Pinouts 6 2 14 USB Connector BT_USB1 PIN NO DESCRIPTION 1 V5A 2 HUB_D1F 3 HUB_D1F 4 GND Table 6 15 USB Connector BT_USB1 Pino...

Page 118: ...le 6 18 USB Connector CAM_USB1 Pinouts 6 3 External Interface Panel Connectors The table below lists the rear panel connectors on the AFL3MB ULT5 motherboard Pinouts of these connectors can be found i...

Page 119: ...1 J1 J2 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 MDIA0 5 MDIA2 2 MDIA0 6 MDIA1 3 MDIA1 7 MDIA3 4 MDIA2 8 MDIA3 Table 6 20 Ethernet Connectors LAN1 J1 J2 Pinouts LED Description LED Description A on lin...

Page 120: ...C 5 GND 15 HDMI_SCL 6 HDMI_DATA1 16 HDMI_SDA 7 HDMI_DATA0 17 GND 8 GND 18 5VCC 9 HDMI_DATA0 19 HDMI_HPD 10 HDMI_CLK Table 6 23 HDMI Connector HDMI1 Pinouts 6 3 3 RS 232 422 485 DB 9 Serial Port COM1 P...

Page 121: ...Table 6 25 RS 232 RJ 45 Serial Port COM2 Pinouts 6 3 5 USB 3 2 Gen 2 Connectors USB_CON1 PIN NO DESCRIPTION PIN NO DESCRIPTION 1 USB_VCC 2 USB2_D0 3 USB2_D0 4 GND 5 USB3_RXD0 6 USB3_RXD0 7 GND 8 USB3...

Page 122: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 106 Appendix A A Regulatory Compliance...

Page 123: ...th the essential requirements and other relevant provisions of Directive 2014 53 EU Bulgarian IEI Integration Corp 2014 53 EU esky Czech IEI Integration Corp t mto prohla uje e tento za zen je ve shod...

Page 124: ...4 53 EU Lietuvi Lithuanian IEI Integration Corp deklaruoja kad is ranga atitinka esminius reikalavimus ir kitas 2014 53 EU Direktyvos nuostatas Nederlands Dutch IEI Integration Corp dat het toestel to...

Page 125: ...dolo ili direktive 2014 53 EU Slovensky Slovak IEI Integration Corp t mto vyhlasuje e zariadenia sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 2014 53 EU Suomi Finnish IEI Integratio...

Page 126: ...e interference at his own expense Federal Communication Commission Interference Statement This equipment has been assembled with components that comply with the limits for a Class B digital device pur...

Page 127: ...ironmentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies c...

Page 128: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 112 B Safety Precautions Appendix B...

Page 129: ...o prevent the risk of electric shock make sure power cord is unplugged from wall socket To fully disengage the power to the unit please disconnect the power cord from the AC outlet Refer servicing to...

Page 130: ...components including the AFL3 W15C W19C W22C ULT5 Dry climates are especially susceptible to ESD It is therefore critical that whenever the AFL3 W15C W19C W22C ULT5 is opened and any of the electrical...

Page 131: ...cycle is classified as electronic device in terms of the European Directive 2012 19 EU WEEE and must not be disposed of as domestic garbage EU wide legislation as implemented in each Member State requ...

Page 132: ...l never spray or squirt liquids directly onto any other components To clean the LCD panel gently wipe it with a piece of soft dry cloth or a slightly moistened cloth The interior of the device does no...

Page 133: ...ts is not recommended when cleaning the device as they may damage the plastic parts Vacuum cleaner Using a vacuum specifically designed for computers is one of the best methods of cleaning the device...

Page 134: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 118 C BIOS Menu Options Appendix C...

Page 135: ...ice Mode RS232 66 Serial Port Enabled 67 Console Redirection Disabled 68 Legacy Serial Redirection Port COM1 68 Terminal Type ANSI 69 Bits per second 115200 70 Data Bits 8 70 Parity None 70 Stop Bits...

Page 136: ...age Dev On Port M2_M2 Not RST Controlled 81 Administrator Password 82 User Password 82 Bootup NumLock State On 83 Quiet Boot Enabled 84 Launch PXE OpROM Disabled 84 Option ROM Messages Force BIOS 84 U...

Page 137: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 121 Appendix D D Watchdog Timer...

Page 138: ...INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog Timer unit select in CMOS setup Table D 1 AH 6FH Sub function Cal...

Page 139: ...mer is not deactivated the system will automatically restart after the Timer has finished its countdown EXAMPLE PROGRAM INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV...

Page 140: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 124 Appendix E E Error Beep Code...

Page 141: ...was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available E 2 DXE Beep Codes Number of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not availab...

Page 142: ...AFL3 W15C W19C W22C ULT5 Panel PC Page 126 Appendix F F Hazardous Materials Disclosure...

Page 143: ...yls PBB Polybrominated Diphenyl Ethers PBDE Bis 2 ethylhexyl phthalate DEHP Butyl benzyl phthalate BBP Dibutyl phthalate DBP Diisobutyl phthalate DIBP Housing O O O O O O O O O O Printed Circuit Board...

Page 144: ...ULT5 Panel PC Page 128 F 2 China RoHS RoHS RoHS Pb Hg Cd CR VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O SJ T11364 2014 GB T26572 2011 X SJ T11364...

Reviews: