background image

Safety Precautions

WARNING

CAUTION

May cause electrical shock.

Faulty installation may cause 

electric shock or fire.

Do not install the product in the 

following locations:

Do not perform the following 

actions:

 

Pour water, or clean with water  

   or detergent.

 

Insert fingers or sticks into the 

   openings.

 

Hang on to the product.

Do not damage or extend 

the signal cord.

To avoid the possibility of causing injury to users or damage to properties, please follow 

all explanations written below.

This symbol denotes an action that must NOT be performed.

This symbol denotes an action that must be performed.

Denotes a potential hazard that may result in serious injury 

or death.
Denotes a hazard that may result in minor injury or damage  

to the unit or other equipment.

Do not change specifications, and disassemble or remodel the product.

May cause fire, electrical shock or injury.

Provide a secure wiring connection using the specified cable so that no 

external force is applied to the connector.

May cause fire.

Do not use the product near any medical equipment or automatic control 

equipment. 

(automatic doors and fire alarms, etc.)

Radio wave may interfere with the equipment and may cause incident due to malfunction.

Keep at least 15 cm away from the product if you have a cardiac pacemaker.

Radio wave may interfere with the operation of pacemaker.

Keep the product away from devices such as other wireless devices, 

microwaves and the devices that use 2.4 GHz signal.

Radio wave may interfere with the equipment and may cause incident due to 

malfunction. The product may not work properly depending on locations it is used.

Do not use the product in a high 

humidity location such as a 

bathroom.

The product should be installed 

firmly by a qualified person.

• 

Where flammable gas may leak.

• 

Where water or oil splashes 

   (machine oil included).

 

Where electromagnetic wave 

   generators are installed.

 

Where organic solvents splash.

May cause fire, electrical shock or injury.

May cause electrical shock or injury.

May cause electric shock or fire.

■ 

The following symbols are used to classify and describe the type of instructions.

■ 

If NOT following the instructions or misusing the product, it may cause damage,  

   the levels of damage are categorized and explained as indicated below.

WARNING

CAUTION

Always follow these instructions

2

English

Summary of Contents for FV-SCGPW1

Page 1: ... product Please read these instructions carefully before using this product and save this manual for future use Operating and Installation Instructions 2 3 4 5 6 6 7 7 8 9 9 10 41 48 CONTENTS Safety Precautions How to Install Names of Parts How to Operate Maintenance Abnormal Occurrence How to Use Application Specifications Information Copyright Việt nam Indonesia ...

Page 2: ...automatic control equipment automatic doors and fire alarms etc Radio wave may interfere with the equipment and may cause incident due to malfunction Keep at least 15 cm away from the product if you have a cardiac pacemaker Radio wave may interfere with the operation of pacemaker Keep the product away from devices such as other wireless devices microwaves and the devices that use 2 4 GHz signal Ra...

Page 3: ...enclosed in the packing box If anything is missing contact our After Sales Center or your dealer Ventilator remote controller 1 set Signal cord 10 m Screw M4 2 pcs 1 Embed and fix a switch box in the wall 2 Insert a flathead screwdriver into the groove at the underside of the product to remove the rear cover and unplug the internal cord Unplug the connector on the front cover side Be careful not t...

Page 4: ...ter sign after maintenance Power switch Turning on or off the ventilator Switching the operation modes of the ventilator Decreasing the air volume of the ventilator in Manual mode Increasing the air volume of the ventilator in Manual mode Names of Parts Display Operating switches Installation hole Displaying the indoor air quality Relative humidity Concentration of PM 2 5 Concentration of CO2 Temp...

Page 5: ...d for a period of time the display turns off 1 To turn on the ventilator Fast blinking Touch when the ventilator is operating the Power LED is lighting the ventilator stops operating How to Operate 2 To turn off the ventilator 3 seconds or longer Touch and hold until the display turns off 3 seconds or longer Touch The ventilator starts operating and the Power LED lights up Touch The ventilator sto...

Page 6: ...ilator for the maintenance method In case that only the ventilator has been used before connecting the controller to it the Filter sign may light immediately after the controller connection Reset operation Sign Maintenance details Clean the filter Replace the filter Clean and replace the filter 6 English Change operation modes Touch to change the operation modes This mode detects CO2 and PM2 5 in ...

Page 7: ...lator is not in operation Circuit error Sensor error Motor error Action to be taken Turn off the ventilator and the breaker and then contact your dealer for repairs Turn off the ventilator and the breaker and then contact your dealer for repairs Other defects When the error codes appear Abnormal Occurrence How to Use Application Radio wave may interfere with the equipment and may cause incident du...

Page 8: ...e may change for version upgrade without notice The app is free of charge However there may be additional costs involved with connection and operation For an Android user Android 4 4 and above Search and install the app from Google Play For an iOS user iOS 9 and above Search and install the app from App Store 3 Touch to select the setting mode 4 Follow the instructions on the smartphone app screen...

Page 9: ...device is being restarted which takes about 1 5 minutes This product incorporates the following software 1 The software developed independently by or for Panasonic Corporation 2 The software owned by third party and licensed to Panasonic Corporation 3 The open source software under the BSD license and or equivalent licenses The software categorized as 3 is distributed in the hope that it will be u...

Page 10: ...istered in the United States and other countries The iPhone trademarks is used under license of iPhone Co Ltd Android and Google Play are trademarks or registered trademarks of Google LLC WPATM and WPA2TM are trademarks of Wi Fi Alliance Other names company names product names etc described in this manual are trademarks or registered trademarks of each company In the text some TM and marks are not...