Switch box

(Not supplied)

Front cover

Rear cover

 Do not apply excessive force to the front cover.

 Install the product at a height of 1 to 1.5 m from the floor.

 Install the product vertically to the wall.

 Leave a minimum clearance of 20 cm around the product.

 Do not install the product where exposed to direct sunlight, heat or wind from an air conditioner.

 Do not install the product near windows or doors.

 Install the product in the same room as where the relevant ventilator is installed.

 Do not put obstacles around the product.

 Install the product at least 1 m away from TV, radio or PC.   

Notice

How to Install

Prevent the internal cord from being bitten by the 

    covers.

Use a switch box of the right size for the

    product. Refer to the external 

    dimensions of the product in page 4.

    (Recommended size: 100 x 100 mm or 

    86 x 86 mm)

Rubber packing --------------------------2 pcs
Operating and Installation Instructions -----1 set

Flathead

screwdriver 

Internal cord

Rear cover

Front cover

Be sure to confirm that the following attachments are enclosed in the packing box. 

If anything is missing, contact our After-Sales Center or your dealer.
Ventilator remote controller -----  1 set
Signal cord ----------------------- 10 m
Screw (M4) -----------------------  2 pcs

1. Embed and fix a switch box in the wall.

2. Insert a flathead screwdriver into the groove at the 

    underside of the product to remove the rear cover, 

    and unplug the internal cord. (Unplug the connector 

    on the front cover side.)

Be careful not to damage the product.

Do not apply tension to the internal cord.

Cover the installation holes not used for  

    installation with rubber packing.

5. Reconnect the internal cord to the 

     front cover.

Attach the front cover firmly. 

    (A click will sound when installed correctly.)

Rear cover

Switch box

Rear cover

Signal cord

Switch box

Connector

Rear cover

Front cover

Internal cord

■ 

Before installation

■ 

How to install

4. Fix the rear cover to the switch box with screws.

    (Use supplied or commercially-available screws 

    suitable for the switch box.)

3. Plug the signal cord into the connector on 

    the rear cover. (Connect the other side of 

    the signal cord to the relevant ventilator.)

6. Attach the front cover to the rear cover.

Screws

(supplied or

commercially-

available) 

Rubber packing

3

English

Do not unplug this cord.

Groove

Summary of Contents for FV-SCGPW1

Page 1: ... product Please read these instructions carefully before using this product and save this manual for future use Operating and Installation Instructions 2 3 4 5 6 6 7 7 8 9 9 10 41 48 CONTENTS Safety Precautions How to Install Names of Parts How to Operate Maintenance Abnormal Occurrence How to Use Application Specifications Information Copyright Việt nam Indonesia ...

Page 2: ...automatic control equipment automatic doors and fire alarms etc Radio wave may interfere with the equipment and may cause incident due to malfunction Keep at least 15 cm away from the product if you have a cardiac pacemaker Radio wave may interfere with the operation of pacemaker Keep the product away from devices such as other wireless devices microwaves and the devices that use 2 4 GHz signal Ra...

Page 3: ...enclosed in the packing box If anything is missing contact our After Sales Center or your dealer Ventilator remote controller 1 set Signal cord 10 m Screw M4 2 pcs 1 Embed and fix a switch box in the wall 2 Insert a flathead screwdriver into the groove at the underside of the product to remove the rear cover and unplug the internal cord Unplug the connector on the front cover side Be careful not t...

Page 4: ...ter sign after maintenance Power switch Turning on or off the ventilator Switching the operation modes of the ventilator Decreasing the air volume of the ventilator in Manual mode Increasing the air volume of the ventilator in Manual mode Names of Parts Display Operating switches Installation hole Displaying the indoor air quality Relative humidity Concentration of PM 2 5 Concentration of CO2 Temp...

Page 5: ...d for a period of time the display turns off 1 To turn on the ventilator Fast blinking Touch when the ventilator is operating the Power LED is lighting the ventilator stops operating How to Operate 2 To turn off the ventilator 3 seconds or longer Touch and hold until the display turns off 3 seconds or longer Touch The ventilator starts operating and the Power LED lights up Touch The ventilator sto...

Page 6: ...ilator for the maintenance method In case that only the ventilator has been used before connecting the controller to it the Filter sign may light immediately after the controller connection Reset operation Sign Maintenance details Clean the filter Replace the filter Clean and replace the filter 6 English Change operation modes Touch to change the operation modes This mode detects CO2 and PM2 5 in ...

Page 7: ...lator is not in operation Circuit error Sensor error Motor error Action to be taken Turn off the ventilator and the breaker and then contact your dealer for repairs Turn off the ventilator and the breaker and then contact your dealer for repairs Other defects When the error codes appear Abnormal Occurrence How to Use Application Radio wave may interfere with the equipment and may cause incident du...

Page 8: ...e may change for version upgrade without notice The app is free of charge However there may be additional costs involved with connection and operation For an Android user Android 4 4 and above Search and install the app from Google Play For an iOS user iOS 9 and above Search and install the app from App Store 3 Touch to select the setting mode 4 Follow the instructions on the smartphone app screen...

Page 9: ...device is being restarted which takes about 1 5 minutes This product incorporates the following software 1 The software developed independently by or for Panasonic Corporation 2 The software owned by third party and licensed to Panasonic Corporation 3 The open source software under the BSD license and or equivalent licenses The software categorized as 3 is distributed in the hope that it will be u...

Page 10: ...istered in the United States and other countries The iPhone trademarks is used under license of iPhone Co Ltd Android and Google Play are trademarks or registered trademarks of Google LLC WPATM and WPA2TM are trademarks of Wi Fi Alliance Other names company names product names etc described in this manual are trademarks or registered trademarks of each company In the text some TM and marks are not...

Reviews: