12
INSTALLATION
Before installing the Range Hood, carefully read chap. "GENERAL SAFETY INFORMATION".
Installation preparation
- Measure the height H from the hob to the ceiling and identify the height Y, taking into consideration the minimum
distance X, between the bottom of the Range hood and the hob.
- Determine the installation method by the height Y.
- Install reinforcement wooden frames to hold the Range Hood.
X
min. 25 9/16” min. 650 mm
min. 29 1/4”
- max. 46 7/32”
min. 743 mm - max. 1174 mm
( Top View )
13 7/8” - 353 mm
Reinforcement
wooden frame
Screw position
Screw position
Scr
ew position
Scr
ew position
Reinforcement
wooden frame
Range
Hood
outline
Joist
Joist
Reinforcement wooden frame structure
【
Installation with trellis and element
】
Y
H
Joist
9 5/8”
245 mm
Reinforcement
wooden frame
CEILING
Trellis
Element
( Top View )
13 7/8” - 353 mm
Reinforcement
wooden frame
Range
Hood
outline
Reinforcement wooden frame structure
【
Installation with element and
extension
support element
】
Joist
9 5/8”
245 mm
X
min. 25 9/16” min. 650 mm
26 3/8” 670 mm
Reinforcement
wooden frame
Y
H
Element
Extension support
element