WIRING DIAGRAM
SPECIFICATIONS
Rated
Voltage
[V]
220
50
230
60
4.0
4.0
15
16
23.5
25.5
1.1
Rated
Frequency
[Hz]
Power
Consumption
[W]
Air Volume
[m
3
/h]
Noise
[dB]
Net weight
[
NJ
]
Value of power consumption, Air volume and noise are measured when the static
pressure is 0 Pa.
Air volume is the central value measured by this company with a range of ±10% tolerance.
Noise is the A weighted sound pressure level, which is the central value measured by this
company, its tolerance range is from +3 dB to -7 dB. The method to measure is as follows:
in an anechoic chamber, measure noise value 1 m away from the front, left and beneath
of the product, then get the average value.
This product comply with the IPX2 requirement against the water drop experiment.
The applicable ambient temperature of this product is in the range of -10 °C~40 °C,
using it out of this range may cause a fault.
The above specification may be changed without prior notice.
8
1 Install the product on a rigid and flat surface. This requirement does not apply to
portable or non-removable parts.
2 Store the product in dry rooms.
3 When transport the product, please avoid its dropping, vibration, and impactting
other objects.
4 The lifetime (durability) of this product is 7 years from the date of manufacture,
but please assure that the product is used in strict conformity with the operating
manual and the technical standards applicable to this product.
Disposing of Waste Electrical & Electronic Equipment
Do not utilize this product with the domestic refuse.
For appropriate utilization you have to address to the organizations,
that are collect and recycle waste Electrical and Electronic Equipment.
You can get information of such organizations from the state/municipal
administrations. An appropriate utilization of the good will help to save
valuable resources and to avoid negative effects on the people's health
and environment, which can take place in case of incorrect utilization.