Do not inspect and maintain the
product by unqualified persons.
TEST RUN
USE AND MAINTENANCE INSTRUCTIONS
Does the fan rotate?
Does the blue LED light?
Does it have abnormal vibration or noise?
Please check the following items by test run after connecting power.
WARNING
Otherwise, it may cause electric
shock or personal injury.
Before touching the product, ensure
that the power switch is turned off.
Otherwise, it may result in electric
shock.
The fan may rotate even when power
supply is switched off. Please make sure
the fan has been stopped before
inspection.
Otherwise, it may cause injury if finger
or object is caught into the rotating
section.
Once flammable gas leaks, do not
start any function of this product.
Otherwise, it may generate spark
and thus lead to explosion.
Do not spray or clean this product
directly with water or other liquid.
Otherwise, it may cause short
circuit or electric shock.
If you will not use this product any more,
remove the product.
This product may cause injuries once
it falls off.
Do not disassemble this product for
repair or reconstruction.
Doing this may lead to fire and
electric shock.
CAUTION
When you check or clean the product,
please wear gloves.
Otherwise, it may result in personal
injury.
Do not insert the finger to the louver
gap when cleaning the louver.
Otherwise, it may result in personal
injury.
Notice
3. Do not use petrol, benzene, thinner or any other such alkaline detergent
for cleaning the product.
1. According to the condition of using environment, routine maintenance is required at least
once a year.
2. Do not immerse blade or other resin parts in hot water over 60 °C.
petrol
thinner
benzene
Clean the dust on surface of louver with a cloth adding neutral cleanser, and then dry
the louver with a soft dry cloth.
Do not insert the finger or
rarity into the nanoe
TM
X exit.
Otherwise, it may cause short
circuit or electric shock.
nanoe
TM
X exit
6
Alkaline detergent