Continuous Communication in Industrial Applications

Program/Operate the PLC using an Ethernet Network

FP Web-Server

9

The multifunctional FP Web-Server provides users with the option of connecting any FP Series PLC to the Internet/Intranet for  
bi-directional communication via Ethernet. No changes to the PLC programs are necessary. Simply assign an IP address to the  
FP Web-Server and connect the PLC to the FP Web-Server via the serial RS3C interface. A standard browser, e.g. MS Internet 
Explorer, can be used for access at the PC. The Windows-based program FP Web Configurator Tool helps you easily set up and 
configure the FP Web-Server. 

The FP Web-Server´s 3 interfaces

100Base-TX / 10Base-T (RJ45, twisted pair)
– connects to the Ethernet at 100Mbit/s

RS3C (screw terminal)
– connects to the PLC at 100 to 115.kbit/s

RS3C (SUB-D 9 male)
– connects to a modem

FP Web-Server advantages 

Uses existing Intranet, saves wiring. 
Uses standard browser, saves Scada software. 
Remote control. 
Remote monitoring. 
Remote programming. 
Alarm information via e-mail.






Highlights

Web-Server: 

PLC data presented as HTML (or XML) pages

Access via standard Internet browser.
PLC data handling via HTML and Java Applet.
Optional: Password protection, IP lock security.

RS232C device server:

Ethernet <-> RS3C conversion (MEWTOCOL).
Transparent RS3C data tunneling via Ethernet.
Programming and visualization via TCP or UDP.

Modem dial-out / Internet system:

FP Web-Server can dial-out to the Internet.
Various Internet / GPRS system solutions. 

Modbus-TCP protocol:

 Communication via standard industrial Ethernet  
protocol (server and client).
Gateway for Modbus-RTU units (master and slave).

IEC 60870-5-101 and IEC 60870-5-104 protocol:

 Communication via RS3C, RS485 adapter,  
multipoint modem, dial-up modem, Ethernet.






Network time server synchronization:

PLC real-time clock update via NTP server.

E-mail

PLC can send e-mails.
E-mail via LAN e-mail server or Internet dial-up.
PLC-defined or pre-stored e-mail text.
PLC data array as attachment to an e-mail.

Modem dial-in / Ethernet gateway:

FP Web-Server can be dialed up via modem.
One remote gateway for multiple FP Web-Servers.





Specifications

Current consumption

65mA

Operating voltage

4VDC (10.8-6.4VDC)

Communication interfaces

RS3C for connection to a PLC, RS3C for modem  

connection, 100Base-TX/10Base-T, Ethernet

Communication protocol

MEWTOCOL, DNS, HTTP, SMTP, FTP TELNET, TCP/IP, UDP/

IP, PPP, SNTP, Modbus

Safety

Passwords, IP lock

Ambient temp.

0°C to 55°C

Storage temp.

-0°C to +0°C

Dimensions

5W x 90H x 60D (mm)

Weight

0.11kg

FPWEB

09/2007

Summary of Contents for FP2 Series

Page 1: ...FP2 FP2SH Series Programmable Controllers 09 2007...

Page 2: ...r cost performance Standard type FP2 C1 With 64 input points FP2 C1D With S LINK FP2 C1SL 60k step standard type FP2 C2 60k step type for small PC card FP2 C2P 120k step type for small PC card FP2 C3P...

Page 3: ...s program memory or expanded data memory I O point expansion by adding backplanes See page 14 for details Optional memory for FP2SH CPU backplane H type backplane Up to three backplanes can be added t...

Page 4: ...Controls up to 256 axes adequately supporting large scale equipment control Up to 32 eight axis units can be connected and up to 256 axes controlled when using FP2SH with H type backplane Selectable...

Page 5: ...can control up to 4 axes Stepping motor Servomotor Motor driver Motor driver Motor driver Motor driver High speed counter units and pulse I O units Interrupt counting pulse output and PWM output func...

Page 6: ...channels Industry s fastest level High speed achieved by highly reliable isolation among channels Temperature conversion 20ms ch Voltage conversion 5ms ch Without insulation setting 500ms ch Industry...

Page 7: ...rformance PLC FP Sigma and FP X can be established by using a combination of the multi communication unit and an RS485 communication block This mode enables the efficient connection of FP2 FP2SH FP Si...

Page 8: ...DB9F 9 pin Sub D female PROFIBUS Plug in module AFPN AB6 00 Various types of plug in network blocks can be mounted in the device at any phase between manufacturer and end customer without having to w...

Page 9: ...l Password protection IP lock security RS232C device server Ethernet RS232C conversion MEWTOCOL Transparent RS232C data tunneling via Ethernet Programming and visualization via TCP or UDP Modem dial o...

Page 10: ...F mode FP I O terminal board FP0 control unit FP0 I O link unit FP control unit FP0 I O link unit FP I O terminal unit Manifold solenoid valve S LINK S LINK is a link system that allows the free layou...

Page 11: ...r commercially available PC Display panel Remote monitoring via a modem Modem Public line Modem Commercially available cable Special cable available from Panasonic FP2 PCWAY for easy data collection T...

Page 12: ...oints 1024 points in total 6000 words Analog I O High speed counter Pulse output RS232C port Serial Available by adding analog input and analog output units Available by adding high speed counter unit...

Page 13: ...Remote I O PLC Link Computer Link Modem connection Program block edit during RUN Constant scan Clock Calendar function 100V to 120VAC 200V to 240VAC 100V to 240VAC 24VDC varies with different models 1...

Page 14: ...With S LINK FP2 C1SL Standard type 60k steps FP2 C2 Expansion cable 60cm FP2 EC Expansion cable 2m FP2 EC2 Dummy unit FP2 DM For small PC card 60k steps FP2 C2P For small PC card 120k steps FP2 C3P 24...

Page 15: ...nt PNP transistor output FP2 Y64P 32 point input 32 point NPN output mixed FP2 XY64D2T FP2 XY64D7T 32 point input 32 point PNP output mixed FP2 XY64D2P FP2 XY64D7P FP2 EM1 FP2 EM2 FP2 EM3 FP2 EM6 FP2...

Page 16: ...utput variables are defined once in the global variable list Multiple address assigment is caught automatically by the compiler Type safe programming using simple or complex data types Functions can b...

Page 17: ...exchanged using a CSV file An icon or tool tip notifies the user about possible errors in configuration The FP OPC Server allows you to clearly structure your application e g by grouping elements in m...

Page 18: ...2ms or less 32 point DC input type FP2 X32D2 24VDC Approx 4 3mA at 24VDC Approx 5 6k 19 2V 4mA 5 0V 1 5mA 0 2ms or less 0 3ms or less 64 point DC input type FP2 X64D2 24VDC Approx 4 3mA at 24VDC Appr...

Page 19: ...be actuated simultaneously is limited by the input voltage and the ambient temperature The maximum load current is limited by the external power supply voltage 1 The current capacity of each common te...

Page 20: ...Output range digital input Resolution Conversion speed Overall accuracy Insulation method Analog output Analog output unit FP2 DA4 4 channels 10V K 2048 to K 2047 0 to 20mA K0 to K4095 1 4096 500 s ch...

Page 21: ...assing Floating master 1 master The number of input and output points for each channel can be selected by the switch in the unit body Input 0 32 64 96 128 points Output 0 32 64 96 128 points 24VDC 10...

Page 22: ...points Output 0 32 64 96 128 points 24VDC 10 Maximum allowable ripples P P 10 S LINK terminal block IN 24VDC 1 6 A or less Current consumption of the S LINK controller incl D G line current consumptio...

Page 23: ...eration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption at 5 VDC External power Command units Max pulse count Command ran...

Page 24: ...C 0 1A 12 to 24VDC 50mA 5VDC FP2 X16D2 FP2 X32D2 FP2 X64D2 FP2 Y6R FP2 Y16R FP2 Y16T FP2 Y32T Note Please refer to FP Sigma Product Types for FP Memory Loader Notes 1 For FP2 CPU unit the capacity can...

Page 25: ...Specification Specification Product number Product number Product number Product name Product name Product name Note Pressure welding socket is supplied A special tool part number AXY52000 is needed f...

Page 26: ...k for DeviceNet CANopen Plug In Module 1ch AFPN AB6218 Plug In network block for CANopen Number of I O points Not insulated Voltage 1 to 5V 10 to 10V Current 4 to 20mA 20 to 20mA Insulated Voltages cu...

Page 27: ...tional 7 module type backplane Mounting dimension Tolerance 1 0 in mm Conventional backplanes 5 module 7 module 9 module 12 module 14 module L1 mm 140 209 265 349 405 L2 mm 130 199 255 339 395 H type...

Page 28: ...ic Electric Works Italia s r l Building Materials Division Piazza della Repubblica 24 20154 Milano MI Tel 02 29005391 Fax 02 29003466 Nordic Countries Panasonic Electric Works Nordic AB PEW Fire Secur...

Reviews: