Multi-wire link units

Performance Specification

Transmission specifications for communication interface

16

                                                                          

Start-stop synchronization

 


RS232C   RS485

Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com

Specifications

Item

Item

100BASE-TX

Item

FP2-MW

W mode

Token bus

Base band

500kbit/s

500kbit/s

500kbit/s, 250kbit/s

W2 mode 

1)

F mode

Polling

Item

VE mode (PLC link)

FL-net mode

Mode
Communication method
Transmission method
Transmission speed

Transmission 
distance

Number of 
connectable stations
Transmission error check
Synchronization
Interface

Transmission line

RAS function

Extendable to 800m

250kbits/s: 1200m max.

500kbits/s: 800m max.

Extendable to 800m

32 stations max.

Twisted-pair cable

Hardware self-diagnosis function

Twisted-pair cables 

or VCTF cables

Extendable to 700m

CRC (cyclic redundancy check) system

Start-stop synchronization

RS485 compatible

S-LINK units

FP2-SL2 

1

128 points max.

CPU unit with S-LINK ports

FP2-C1SL

2

128 points max. 

× 

2

Item

Number of channels

Number of I/O 
points

Rated power 
supply voltage

Power 
consumption

Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT

Connection method

* For FP2SH (Cannot be used for FP2)

1)

note 2)

note 2)

note 3)

1)

1)

1)

2)

2)

10BASE5 : 500m (2500m)
10BASE-T : 100m (500m)

FL-net [FA link protocol (UDP/IP)]

MEWTOCOL

Communication 
interface
Communication speed

Cycle time 
example

Cable length

Communication protocol

Link 
communication 
specifications

Message communication 
specifications
Number of nodes

Other functions

Ethernet

10BASE5/10BASE-T

10Mbit/s

50ms/32 units

(2048 points/2048 words)

Link relay

8192 points/unit

Link register

8192 words/unit

2048 bytes max.

(Compatible with MEWTOCOL)

99 units max.

Data transfer

Remote programming

Multilevel link communications

1024 bytes max.

(Not compatible with MEWTOCOL)

254 units max.

Interconnection with other 

companies' units

Communication 

block used
Interface
Communication 

method
Synchronization

Transmission line

Transmission distance
Transmission speed

(To be set in the system register)

Transmission code

Transmission format

(To be set in the system register)

Number of stations

PLC link capacity

COM1 (upper channel)
COM2 (lower channel)
Number of attachable units
Supported versions

General-purpose serial communications

Computer link

(Panasonic open protocol "MEWTOCOL" should be used.)

1:1 communications

1:N communications

1:1 communications

1:N communications

FP2-CB232
FP2-CB422

RS232C  RS422

Full duplex

FP2-CB232
FP2-CB422

RS232C  RS422

Full duplex

FP2-CB232
FP2-CB422

Three-core or 

five-core shielded wire

15m   Length: 1200m max.

300 to 230,400bps

Twisted-pair cable 

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

16 stations max.

Link relay: 1024 points

Link register: 128 words

 

Three-core or 

five-core shielded wire

15m   Length: 1200m max.

300 to 230,400bps

Twisted-pair cable 

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

FP2-CB485

RS485

Two-wire half duplex

FP2-CB485

RS485

Two-wire half duplex

ASCII, JIS7, JIS8, and binary

Start code: With STX / Without STX

End code: CR/CR+LF/Time setting/ETX

Data length: 7 bits/8 bits

Parity: 0/Invalid/Valid (Odd/Even)

Stop bit: 1 bit/2 bits

23 units max. (including 8 units for the computer link and 2 channels for the PLC link)

CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later

ASCII, JIS7, JIS8

PLC link function

Twisted-pair cable 

or VCTF

1200m (RS485)  15m (RS232C)

115,200bps

Token passing

(Floating master)

1  

32 slave stations max.

Note 1: When the unit is used in W2 mode, it must be set by user programs.

The number of input and output points for each channel can be selected by the switch in the unit body

Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points

+24VDC  

±

10% Maximum allowable ripples (P-P): 

±

10%

(S-LINK terminal block IN-24VDC 1.6 A or less)

[Current consumption of the S-LINK controller (incl. D-G line current 

consumption)] +24VDC 1.6A or less

[Maximum allowable current supply (Supply to the S-LINK and I/O 

devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)

Bi-directional time division multiplex transmission

Bit/Frame synchronization

S-LINK protocol

28.5kbit/s

Main signal line: Extendable to 200m (max. 400m when a booster is used)

320

T-branch multi-drop wiring or standard multi-drop wiring

[+24, 0V, D-G (with a function of D-G short-circuit protection)]

Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design 

Manual for details of the current consumption.

 

  2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m 

A
A

A
A

A
A

A
A

A

N/A

A: Available
N/A: Not available

* The lengths in parentheses are 

available when a repeater is used.

Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite 

core may be necessary in some cases, depending on the usage environment. Also, if the hub is 

positioned close to a control board, we recommend using it at a distance of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite 

core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is 

positioned close to a control board, we recommend using it at a distance of 5m or less.

Communications function

Number of communication connections
Transparent 

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)  

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable 
length
Max. number of nodes
Node spacing

S-LINK units

Performance Specification

Transmission specifications for communication interface

16

                                                                          

Start-stop synchronization

 


RS232C   RS485

Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com

Specifications

Item

Item

100BASE-TX

Item

FP2-MW

W mode

Token bus

Base band

500kbit/s

500kbit/s

500kbit/s, 250kbit/s

W2 mode 

1)

F mode

Polling

Item

VE mode (PLC link)

FL-net mode

Mode
Communication method
Transmission method
Transmission speed

Transmission 
distance

Number of 
connectable stations
Transmission error check
Synchronization
Interface

Transmission line

RAS function

Extendable to 800m

250kbits/s: 1200m max.

500kbits/s: 800m max.

Extendable to 800m

32 stations max.

Twisted-pair cable

Hardware self-diagnosis function

Twisted-pair cables 

or VCTF cables

Extendable to 700m

CRC (cyclic redundancy check) system

Start-stop synchronization

RS485 compatible

S-LINK units

FP2-SL2 

1

128 points max.

CPU unit with S-LINK ports

FP2-C1SL

2

128 points max. 

× 

2

Item

Number of channels

Number of I/O 
points

Rated power 
supply voltage

Power 
consumption

Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT

Connection method

* For FP2SH (Cannot be used for FP2)

1)

note 2)

note 2)

note 3)

1)

1)

1)

2)

2)

10BASE5 : 500m (2500m)
10BASE-T : 100m (500m)

FL-net [FA link protocol (UDP/IP)]

MEWTOCOL

Communication 
interface
Communication speed

Cycle time 
example

Cable length

Communication protocol

Link 
communication 
specifications

Message communication 
specifications
Number of nodes

Other functions

Ethernet

10BASE5/10BASE-T

10Mbit/s

50ms/32 units

(2048 points/2048 words)

Link relay

8192 points/unit

Link register

8192 words/unit

2048 bytes max.

(Compatible with MEWTOCOL)

99 units max.

Data transfer

Remote programming

Multilevel link communications

1024 bytes max.

(Not compatible with MEWTOCOL)

254 units max.

Interconnection with other 

companies' units

Communication 

block used
Interface
Communication 

method
Synchronization

Transmission line

Transmission distance
Transmission speed

(To be set in the system register)

Transmission code

Transmission format

(To be set in the system register)

Number of stations

PLC link capacity

COM1 (upper channel)
COM2 (lower channel)
Number of attachable units
Supported versions

General-purpose serial communications

Computer link

(Panasonic open protocol "MEWTOCOL" should be used.)

1:1 communications

1:N communications

1:1 communications

1:N communications

FP2-CB232
FP2-CB422

RS232C  RS422

Full duplex

FP2-CB232
FP2-CB422

RS232C  RS422

Full duplex

FP2-CB232
FP2-CB422

Three-core or 

five-core shielded wire

15m   Length: 1200m max.

300 to 230,400bps

Twisted-pair cable 

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

16 stations max.

Link relay: 1024 points

Link register: 128 words

 

Three-core or 

five-core shielded wire

15m   Length: 1200m max.

300 to 230,400bps

Twisted-pair cable 

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

FP2-CB485

RS485

Two-wire half duplex

FP2-CB485

RS485

Two-wire half duplex

ASCII, JIS7, JIS8, and binary

Start code: With STX / Without STX

End code: CR/CR+LF/Time setting/ETX

Data length: 7 bits/8 bits

Parity: 0/Invalid/Valid (Odd/Even)

Stop bit: 1 bit/2 bits

23 units max. (including 8 units for the computer link and 2 channels for the PLC link)

CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later

ASCII, JIS7, JIS8

PLC link function

Twisted-pair cable 

or VCTF

1200m (RS485)  15m (RS232C)

115,200bps

Token passing

(Floating master)

1  

32 slave stations max.

Note 1: When the unit is used in W2 mode, it must be set by user programs.

The number of input and output points for each channel can be selected by the switch in the unit body

Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points

+24VDC  

±

10% Maximum allowable ripples (P-P): 

±

10%

(S-LINK terminal block IN-24VDC 1.6 A or less)

[Current consumption of the S-LINK controller (incl. D-G line current 

consumption)] +24VDC 1.6A or less

[Maximum allowable current supply (Supply to the S-LINK and I/O 

devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)

Bi-directional time division multiplex transmission

Bit/Frame synchronization

S-LINK protocol

28.5kbit/s

Main signal line: Extendable to 200m (max. 400m when a booster is used)

320

T-branch multi-drop wiring or standard multi-drop wiring

[+24, 0V, D-G (with a function of D-G short-circuit protection)]

Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design 

Manual for details of the current consumption.

 

  2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m 

A
A

A
A

A
A

A
A

A

N/A

A: Available
N/A: Not available

* The lengths in parentheses are 

available when a repeater is used.

Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite 

core may be necessary in some cases, depending on the usage environment. Also, if the hub is 

positioned close to a control board, we recommend using it at a distance of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite 

core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is 

positioned close to a control board, we recommend using it at a distance of 5m or less.

Communications function

Number of communication connections
Transparent 

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)  

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable 
length
Max. number of nodes
Node spacing

Item

Transistor

Line driver

Output type 
Number of axes controlled 
Position 

command 

Speed 
command 

Acceleration/
deceleration 
command 

 

Home return 

 
 
 
 

Operation mode 

 
 
 
 

Startup time
Output interface
Feedback 
counter

Other functions

Internal current consumption (at 5 VDC)

External power 

supply

Command units 
Max. pulse count 
Command 
range 

Acceleration/
deceleration 

“S” Acceleration/
deceleration
Acceleration/
deceleration time
Home return speed
Input terminals
Output terminals

Output mode
Countable range
Input mode

Voltage
Current consumption

FP2-PP21

FP2-PP41

FP2-PP22

FP2-PP42

21.6VDC to 26.4VDC

200mA max.

50mA

350mA max.

90mA

200mA max.

50mA

350mA max.

90mA

Notes: Previous FP2 positioning units FP2-PP2 and FP2-PP4 are not compatible with the multi-function  
           type FP2 positioning unit.  Please contact us.

  * 2-phase input cannot be used with multiples of one.

2-axis type

FP2-PN2AN

4-axis type

FP2-PN4AN

8-axis type

FP2-PN8AN

Speed control function
Torque control function

Product number

Home 
return

Others

Communication speed
Cables
Connection system

Communication cycle/
Number of connectable stations
Transmission distance

Counter

Interrupt

Part no.

Product number

Output 
specifi-
cations

Counter

Pulse 
output 

PWM 
output 

Insulation method 
Rated voltage 
Rated current 
Input impedance 
Usage voltage range 
Min. ON voltage/Min. ON current 
Min. OFFvoltage/Min. OFFcurrent 
Response 
time 

Input time constant setting 
Common method 
Number of counter channels 
Calculation range 
Max. calculation speed 
Input modes 
Max. calculation speed 
Other 
Number of interrupt points 
Interrupt processing 

delays 
Insulation method 
Rated load voltage 
Rated load voltage range 
Max. load current 
Leakage current when off 
Max. voltage drop when on 
Response 

time 
 

Surge absorber 
Common method 

External power 

supply 

Surge absorber 
Channels 
Max. output frequency 
Output modes 
Number of output points 
Max. load current 
Cycle 
Duty 

Item

Item

OFF

ON

ON

OFF

OFF

ON

ON

OFF

Voltage
Current

(when using 24VDC)

FP2 High-speed counter unit

FP2-HSCT (NPN)
FP2-HSCP (PNP)

FP2 Pulse I/O unit

FP2-PXYT (NPN)

 

Photocoupler insulation

24VDC

Approx. 7.5mA (when using 24VDC)

Approx. 3.2k

20.4VDC to 26.4VDC

19.2V /6mA

5.0V /1.5mA

1

µ

s or less

2

µ

s or less

None, 4

µ

s, 8

µ

s, 16

µ

s, 32

µ

s (set in 2-input units)

16 points/common (+ common)

4 channels

32-bit with sign (–2147483648 to +2147483647)

200kHz

3 modes (direction control, individual input, phase input)

2.5

µ

s

8 comparison outputs, multiplier function (1, 2, 4)

None, 1/unit, 8/unit (set with mode setting switches)

160

µ

s max. (when using FP2 CPU unit)

50

µ

s max. (when using FP2SH CPU unit)

Photocoupler insulation

5 to 24VDC

4.75VDC to 26.4VDC

0.1A (A11 to A18, B11 to B14 pins), 0.8A (B15 to B18 pins)

1

µ

A max.

0.5V max.

1

µ

s max.

1

µ

s or less (NPN)

5

µ

s or less (PNP)

Zener diode

16 points/common

20.4VDC to 26.4VDC

90mA or less (NPN)

200mA or less (PNP)

8 points (A11 to A18 pins)

4CH (B11 to B18 pins)

100kHz

2 modes (direction control, individual output)

4CH (B15 to B18 pins)

0.8A

1Hz to 30kHz

0 to 100% (unit: 1%)

1)

1)

2)

3)

3)

1)

1pps to 500kpps 

(can set in 1pps)

1pps to 4Mpps 

(can set in 1pps)

Unit specifications

Position 
control 
function

Control method
Interpolation control
Unit of control
Positioning data
Backup
Acceleration/
deceleration method
Acceleration/
deceleration time
Positioning range

Search method
Creep rate

Communication specifications

PTP control, continuous path (CP) control

Two/Three-axis linear interpolation, two-axis circular interpolation, three-axis helical interpolation

Pulse/

µ

m/inch/degree

600 points per axis

Parameters and data tables can be saved in FROM

Linear/S-curve acceleration and deceleration

0 to 10,000ms (in increments of 1ms)

(-1073741823 to +1073741823 pulses) Increment/Absolute specification

Supported by a JOG operation (free-run operation)

Supported by a real-time torque control function

Home proximity (DOG) search

Can be set freely

Pulser input operation supported

Auxiliary output code and auxiliary output contact

Dwell time 

In-position contact

100Mbps

Commercially available LAN straight cable (Category 5e shielded cable)

Ring

0.5ms, 8 axes max./system (Command cycle: 1ms)

Between terminals: 60m Total: 200m

2 axes, independent 4 axes, independent 2 axes, independent 4 axes, independent

Pulse unit (the program specifies whether Increment or Absolute is used.)

Signed 32 bits (–2147483648 to +2147483647 pulses)

Linear acceleration/deceleration, 

S acceleration/deceleration (this takes the form of an “S”)

Can select from Sin curve, Secondary curve, 

Cycloid curve and Third curve

0 to 32,767ms (can set in 1ms)

Speed setting possible (changes return speed and search speed)

Home input, Near home input, Over limit input (+), Over limit input (–)

Deviation counter clear output signal

E point control (Linear and S accelerations/decelerations selecting possible)
P point control (Linear and S accelerations/decelerations selecting possible)
Home return function (Home search)
JOG operation function
JOG positioning function
Pulser input function
Transfer multiplication ratio 
(

×

1, 

×

2, 

×

5, 

×

10, 

×

50, 

×

100, 

×

500, 

×

1000 selecting possible)

Real-time frequency change function
Infinity output function

0.02ms or 0.005ms possible

1 pulse output (Pulse/Sign), 2 pulse output (CW/CCW)

Signed 32-bit (–2147483648 to +2147483647 pulse)

2-phase input*, Direction distinction input, Individual input (transfer multiple available for each)

The flag to compare the elapsed value is built-in

(The timing signal outputs at the optional position during an operation)

Notes:
1)  This value is effective when the input time constant (filter) setting was set to "No setting".
2)  If interrupts are used at the 1/unit setting, the interrupt from the external input terminal B1 (X8) or 

the interrupt program from the comparison 0 (one of among INT16 to INT23) is booted.

3)  At maximum load current and resistance load. There may be distortion in the output waveform, 

depending on the load current and type of load.

Positioning units: RTEX (Network type)

FNS (Flexible Network Slave) specifications:

FP2/FP2SH

Specifications

NEW!

Item

PROFIBUS

DeviceNet

CANopen

Baud rate

• Automatic baud rate detection

• 9.6 kbaud to 1Mbaud

• Automatic baud rate detection

• 15kbps to 500kbps

• Automatic baud rate detection

• 10kbps to 1Mbps

Isolation

Galvanically isolated bus electronics

Galvanically isolated bus electronics

Galvanically isolated bus electronics

Connection types

DP-V0: process data is accessed from the 

PROFIBUS network as cylical I/O data

• Cyclic connections

• COS (Change of State)

• Bit strobe connections

• Polled connections

• Explicit connections

PDO (Process Data Object)

Exchange via:

• Cyclic Synchronous

• Acyclic Synchronous

• COS

• Timer-driven connections

Maximum

inputs / outputs

6 words altogether for inputs and outputs 

(in units of 1,  or 4 words)

E. g. for cyclic connections:

18 words in each direction

Data 18 words

(for TPDOs and RPDOs)

Additional features

Diagnostic support

• UCMM capable

• CIP parameter object

• Diagnostic support

Diagnostic support

09/2007

Summary of Contents for FP2 Series

Page 1: ...FP2 FP2SH Series Programmable Controllers 09 2007...

Page 2: ...r cost performance Standard type FP2 C1 With 64 input points FP2 C1D With S LINK FP2 C1SL 60k step standard type FP2 C2 60k step type for small PC card FP2 C2P 120k step type for small PC card FP2 C3P...

Page 3: ...s program memory or expanded data memory I O point expansion by adding backplanes See page 14 for details Optional memory for FP2SH CPU backplane H type backplane Up to three backplanes can be added t...

Page 4: ...Controls up to 256 axes adequately supporting large scale equipment control Up to 32 eight axis units can be connected and up to 256 axes controlled when using FP2SH with H type backplane Selectable...

Page 5: ...can control up to 4 axes Stepping motor Servomotor Motor driver Motor driver Motor driver Motor driver High speed counter units and pulse I O units Interrupt counting pulse output and PWM output func...

Page 6: ...channels Industry s fastest level High speed achieved by highly reliable isolation among channels Temperature conversion 20ms ch Voltage conversion 5ms ch Without insulation setting 500ms ch Industry...

Page 7: ...rformance PLC FP Sigma and FP X can be established by using a combination of the multi communication unit and an RS485 communication block This mode enables the efficient connection of FP2 FP2SH FP Si...

Page 8: ...DB9F 9 pin Sub D female PROFIBUS Plug in module AFPN AB6 00 Various types of plug in network blocks can be mounted in the device at any phase between manufacturer and end customer without having to w...

Page 9: ...l Password protection IP lock security RS232C device server Ethernet RS232C conversion MEWTOCOL Transparent RS232C data tunneling via Ethernet Programming and visualization via TCP or UDP Modem dial o...

Page 10: ...F mode FP I O terminal board FP0 control unit FP0 I O link unit FP control unit FP0 I O link unit FP I O terminal unit Manifold solenoid valve S LINK S LINK is a link system that allows the free layou...

Page 11: ...r commercially available PC Display panel Remote monitoring via a modem Modem Public line Modem Commercially available cable Special cable available from Panasonic FP2 PCWAY for easy data collection T...

Page 12: ...oints 1024 points in total 6000 words Analog I O High speed counter Pulse output RS232C port Serial Available by adding analog input and analog output units Available by adding high speed counter unit...

Page 13: ...Remote I O PLC Link Computer Link Modem connection Program block edit during RUN Constant scan Clock Calendar function 100V to 120VAC 200V to 240VAC 100V to 240VAC 24VDC varies with different models 1...

Page 14: ...With S LINK FP2 C1SL Standard type 60k steps FP2 C2 Expansion cable 60cm FP2 EC Expansion cable 2m FP2 EC2 Dummy unit FP2 DM For small PC card 60k steps FP2 C2P For small PC card 120k steps FP2 C3P 24...

Page 15: ...nt PNP transistor output FP2 Y64P 32 point input 32 point NPN output mixed FP2 XY64D2T FP2 XY64D7T 32 point input 32 point PNP output mixed FP2 XY64D2P FP2 XY64D7P FP2 EM1 FP2 EM2 FP2 EM3 FP2 EM6 FP2...

Page 16: ...utput variables are defined once in the global variable list Multiple address assigment is caught automatically by the compiler Type safe programming using simple or complex data types Functions can b...

Page 17: ...exchanged using a CSV file An icon or tool tip notifies the user about possible errors in configuration The FP OPC Server allows you to clearly structure your application e g by grouping elements in m...

Page 18: ...2ms or less 32 point DC input type FP2 X32D2 24VDC Approx 4 3mA at 24VDC Approx 5 6k 19 2V 4mA 5 0V 1 5mA 0 2ms or less 0 3ms or less 64 point DC input type FP2 X64D2 24VDC Approx 4 3mA at 24VDC Appr...

Page 19: ...be actuated simultaneously is limited by the input voltage and the ambient temperature The maximum load current is limited by the external power supply voltage 1 The current capacity of each common te...

Page 20: ...Output range digital input Resolution Conversion speed Overall accuracy Insulation method Analog output Analog output unit FP2 DA4 4 channels 10V K 2048 to K 2047 0 to 20mA K0 to K4095 1 4096 500 s ch...

Page 21: ...assing Floating master 1 master The number of input and output points for each channel can be selected by the switch in the unit body Input 0 32 64 96 128 points Output 0 32 64 96 128 points 24VDC 10...

Page 22: ...points Output 0 32 64 96 128 points 24VDC 10 Maximum allowable ripples P P 10 S LINK terminal block IN 24VDC 1 6 A or less Current consumption of the S LINK controller incl D G line current consumptio...

Page 23: ...eration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption at 5 VDC External power Command units Max pulse count Command ran...

Page 24: ...C 0 1A 12 to 24VDC 50mA 5VDC FP2 X16D2 FP2 X32D2 FP2 X64D2 FP2 Y6R FP2 Y16R FP2 Y16T FP2 Y32T Note Please refer to FP Sigma Product Types for FP Memory Loader Notes 1 For FP2 CPU unit the capacity can...

Page 25: ...Specification Specification Product number Product number Product number Product name Product name Product name Note Pressure welding socket is supplied A special tool part number AXY52000 is needed f...

Page 26: ...k for DeviceNet CANopen Plug In Module 1ch AFPN AB6218 Plug In network block for CANopen Number of I O points Not insulated Voltage 1 to 5V 10 to 10V Current 4 to 20mA 20 to 20mA Insulated Voltages cu...

Page 27: ...tional 7 module type backplane Mounting dimension Tolerance 1 0 in mm Conventional backplanes 5 module 7 module 9 module 12 module 14 module L1 mm 140 209 265 349 405 L2 mm 130 199 255 339 395 H type...

Page 28: ...ic Electric Works Italia s r l Building Materials Division Piazza della Repubblica 24 20154 Milano MI Tel 02 29005391 Fax 02 29003466 Nordic Countries Panasonic Electric Works Nordic AB PEW Fire Secur...

Reviews: