14

14

FP2/FP2SH

Product Line and Accessories

FP2/FP2SH system configurations and unit lineup

Unit combinations

 Most units occupy one slot, i. e. module each, though some units occupy two slots.
When selecting a backplane, carefully consider the units and number of slots you need.
The power supply unit and CPU unit must be mounted on the CPU backplane.



Power supply units

Input and output units

Optional memories

For FP2SH

Type of memory unit

Analog input/output units

Positioning units

Multi-

communication 

unit

Pulse input/

output units

Link-related units

CPU units

FP2SH

Backplanes

H type backplanes

100VAC,

2.5A type

FP2-PSA1

200VAC,

2.5A type

FP2-PSA2

100 to 240VAC,

5A type

FP2-PSA3

Standard type

FP2-C1

With 64-point input

FP2-C1D

With S-LINK

FP2-C1SL

Standard type

(60k steps)

FP2-C2

Expansion cable 

(60cm)

FP2-EC

Expansion cable 

(2m)

FP2-EC2

Dummy unit

FP2-DM 

For small PC card

(60k steps)

 FP2-C2P

For small PC card

(120k steps)

 FP2-C3P

24VDC,

5A type

FP2-PSD2

(For use as both master and expansion backplanes. The 5-module 
type cannot be used with or as an expansion backplane.)

5-module type
FP2-BP05 

7-module type
FP2-BP07 

9-module type
FP2-BP09 

12-module type
FP2-BP12 

14-module type
FP2-BP14 

H type master backplane
(11 modules): 8 slots
FP2-BP11MH 

H type expansion backplane
(10 modules): 8 slots
FP2-BP10EH 

                                               Type

Power supply unit, 5A type

CPU unit with 64 input points
CPU unit with S-LINK ports

Model No.

FP2-PSA3
FP2-PSD2

FP2-C1D

FP2-C1SL

FP2-EM1
FP2-EM2

F-ROM

FP2-EM4

EP-ROM

FP2-EM5

Analog output 

unit

FP2-DA4

Data clear/

Data hold type

AFP8670/

AFP8671

Multi-communication unit

FP2-MCU

The communication blocks 

are available separately.

Serial data unit

FP2-SDU

Computer 

communication unit

FP2-CCU 

Multi-wire link unit

FP2-MW 

S-LINK

FP2-SL2

Flexible Network Slave

FP2-FNS

ET-LAN

FP2-ET1

Small PC card (2MB)

F-ROM

(AIC50020)

Small PC card (2MB)

SRAM

(AIC52000)

EP-ROM

(AFP5209)

Memory unit 

with ROM socket

FP2-EM7 (AFP2207)

F-ROM

(AFP5208)

AFP8503

AFP8504

FP2-EM3
FP2-EM6
FP2-EM7

16-point DC input
FP2-X16D2 
16-point NPN transistor output
FP2-Y16T 
16-point PNP transistor output
FP2-Y16P 

6-point Relay output (5A)
FP2-Y6R 
16-point Relay output (2A)
FP2-Y16R 

32-point DC input
FP2-X32D2 
32-point NPN transistor output
FP2-Y32T 
32-point PNP transistor output
FP2-Y32P 

64-point DC input
FP2-X64D2 
64-point NPN transistor output
FP2-Y64T
64-point PNP transistor output
FP2-Y64P 
32-point input/32-point NPN output mixed
FP2-XY64D2T 
FP2-XY64D7T 
32-point input/32-point PNP output mixed
FP2-XY64D2P 
FP2-XY64D7P

FP2-EM1
FP2-EM2
FP2-EM3
FP2-EM6
FP2-EM7

FP Memory Loader

FP2-PP21 FP2-PP22

Positioning units

FP2-PP41 FP2-PP42

Positioning units

FP2-PN2AN

Positioning units 

RTEX

FP2-PN4AN

Positioning units 

RTEX

FP2-PN8AN

Positioning units 

RTEX

FP2-HSCT FP2-HSCP

High-speed counter 

unit

FP2-PXYT FP2-PXYP

Pulse I/O

unit

1-axis type

2-axis type

Multiple analog 

input unit

FP2-AD8X

Resistance thermometer 

device input unit

FP2-RTD

Voltage/current 

input unit

FP2-AD8VI

FP2

For FP2

(2-axis)

(4-axis)

(2-axis)

(4-axis)

(8-axis)

Serial data 

control unit

Operation display 

panel and computer 

interface unit

Motor driver I/F 

terminal II

Panasonic servo

MINAS AII/S series

Product 
number

A
A
A

N/A
N/A

Comment

input

function

A
A
A

N/A
N/A

Clock/

calendar

function

N/A

A
A
A

N/A

With 16k

expansion

RAM

N/A
N/A

A
A
A

ROM

socket

A: Available
N/A: Not available

Units that occupy two modules each

09/2007

Summary of Contents for FP2 Series

Page 1: ...FP2 FP2SH Series Programmable Controllers 09 2007...

Page 2: ...r cost performance Standard type FP2 C1 With 64 input points FP2 C1D With S LINK FP2 C1SL 60k step standard type FP2 C2 60k step type for small PC card FP2 C2P 120k step type for small PC card FP2 C3P...

Page 3: ...s program memory or expanded data memory I O point expansion by adding backplanes See page 14 for details Optional memory for FP2SH CPU backplane H type backplane Up to three backplanes can be added t...

Page 4: ...Controls up to 256 axes adequately supporting large scale equipment control Up to 32 eight axis units can be connected and up to 256 axes controlled when using FP2SH with H type backplane Selectable...

Page 5: ...can control up to 4 axes Stepping motor Servomotor Motor driver Motor driver Motor driver Motor driver High speed counter units and pulse I O units Interrupt counting pulse output and PWM output func...

Page 6: ...channels Industry s fastest level High speed achieved by highly reliable isolation among channels Temperature conversion 20ms ch Voltage conversion 5ms ch Without insulation setting 500ms ch Industry...

Page 7: ...rformance PLC FP Sigma and FP X can be established by using a combination of the multi communication unit and an RS485 communication block This mode enables the efficient connection of FP2 FP2SH FP Si...

Page 8: ...DB9F 9 pin Sub D female PROFIBUS Plug in module AFPN AB6 00 Various types of plug in network blocks can be mounted in the device at any phase between manufacturer and end customer without having to w...

Page 9: ...l Password protection IP lock security RS232C device server Ethernet RS232C conversion MEWTOCOL Transparent RS232C data tunneling via Ethernet Programming and visualization via TCP or UDP Modem dial o...

Page 10: ...F mode FP I O terminal board FP0 control unit FP0 I O link unit FP control unit FP0 I O link unit FP I O terminal unit Manifold solenoid valve S LINK S LINK is a link system that allows the free layou...

Page 11: ...r commercially available PC Display panel Remote monitoring via a modem Modem Public line Modem Commercially available cable Special cable available from Panasonic FP2 PCWAY for easy data collection T...

Page 12: ...oints 1024 points in total 6000 words Analog I O High speed counter Pulse output RS232C port Serial Available by adding analog input and analog output units Available by adding high speed counter unit...

Page 13: ...Remote I O PLC Link Computer Link Modem connection Program block edit during RUN Constant scan Clock Calendar function 100V to 120VAC 200V to 240VAC 100V to 240VAC 24VDC varies with different models 1...

Page 14: ...With S LINK FP2 C1SL Standard type 60k steps FP2 C2 Expansion cable 60cm FP2 EC Expansion cable 2m FP2 EC2 Dummy unit FP2 DM For small PC card 60k steps FP2 C2P For small PC card 120k steps FP2 C3P 24...

Page 15: ...nt PNP transistor output FP2 Y64P 32 point input 32 point NPN output mixed FP2 XY64D2T FP2 XY64D7T 32 point input 32 point PNP output mixed FP2 XY64D2P FP2 XY64D7P FP2 EM1 FP2 EM2 FP2 EM3 FP2 EM6 FP2...

Page 16: ...utput variables are defined once in the global variable list Multiple address assigment is caught automatically by the compiler Type safe programming using simple or complex data types Functions can b...

Page 17: ...exchanged using a CSV file An icon or tool tip notifies the user about possible errors in configuration The FP OPC Server allows you to clearly structure your application e g by grouping elements in m...

Page 18: ...2ms or less 32 point DC input type FP2 X32D2 24VDC Approx 4 3mA at 24VDC Approx 5 6k 19 2V 4mA 5 0V 1 5mA 0 2ms or less 0 3ms or less 64 point DC input type FP2 X64D2 24VDC Approx 4 3mA at 24VDC Appr...

Page 19: ...be actuated simultaneously is limited by the input voltage and the ambient temperature The maximum load current is limited by the external power supply voltage 1 The current capacity of each common te...

Page 20: ...Output range digital input Resolution Conversion speed Overall accuracy Insulation method Analog output Analog output unit FP2 DA4 4 channels 10V K 2048 to K 2047 0 to 20mA K0 to K4095 1 4096 500 s ch...

Page 21: ...assing Floating master 1 master The number of input and output points for each channel can be selected by the switch in the unit body Input 0 32 64 96 128 points Output 0 32 64 96 128 points 24VDC 10...

Page 22: ...points Output 0 32 64 96 128 points 24VDC 10 Maximum allowable ripples P P 10 S LINK terminal block IN 24VDC 1 6 A or less Current consumption of the S LINK controller incl D G line current consumptio...

Page 23: ...eration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption at 5 VDC External power Command units Max pulse count Command ran...

Page 24: ...C 0 1A 12 to 24VDC 50mA 5VDC FP2 X16D2 FP2 X32D2 FP2 X64D2 FP2 Y6R FP2 Y16R FP2 Y16T FP2 Y32T Note Please refer to FP Sigma Product Types for FP Memory Loader Notes 1 For FP2 CPU unit the capacity can...

Page 25: ...Specification Specification Product number Product number Product number Product name Product name Product name Note Pressure welding socket is supplied A special tool part number AXY52000 is needed f...

Page 26: ...k for DeviceNet CANopen Plug In Module 1ch AFPN AB6218 Plug In network block for CANopen Number of I O points Not insulated Voltage 1 to 5V 10 to 10V Current 4 to 20mA 20 to 20mA Insulated Voltages cu...

Page 27: ...tional 7 module type backplane Mounting dimension Tolerance 1 0 in mm Conventional backplanes 5 module 7 module 9 module 12 module 14 module L1 mm 140 209 265 349 405 L2 mm 130 199 255 339 395 H type...

Page 28: ...ic Electric Works Italia s r l Building Materials Division Piazza della Repubblica 24 20154 Milano MI Tel 02 29005391 Fax 02 29003466 Nordic Countries Panasonic Electric Works Nordic AB PEW Fire Secur...

Reviews: