Panasonic FP2 Series Product Manual Download Page 26

6

Xxxxx Xxxxxxxx

Xxxxx Xxxxxxxx

Xxxxx Xxxxxxxx

6

FP OPC Server
FP OPC Server license
FP Data Analyzer
PCWAY

CommX

Product name

Description

Product number

Standardized connectivity to FP Series PLCs (software with one license)

Additional license for FP OPC Server

Software tool to read and display PLC data

Data monitoring, logging and setting software based on Excel

OCX for communication, Internal data can be displayed and 

operated on Visual Basic

AFPS03510D
AFPS03517D
AFPS04510D

AFW10031

AFW20031

Other software tools

Number of

channels

10Mbps, 8192 points/8192 words, 99 units max. (VE mode), 254 units max. (FL-net), 2500m

For FP2SH only (Cannot be used for FP2)

Ethernet-compatible unit for FP2/FP2SH

To be mounted on the CPU backplane
ET-LAN unit setting software (English)

For PLC links

Compatible with MEWNET-W/MEWNET-W2

Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks.

General-purpose serial communications, computer links, PLC links (MEWTNET-W0)

(For the multi-communication unit) 230kbps, 15m max.

(For the multi-communication unit) 230kbps, 1200m max.

(For the multi-communication unit) For PLC links (MEWNET-W0): 115kbps, 16 stations, 1,200m

For 1:1 communication between a PLC and a computer

RS232C x 2 ch Connection with a control panel is also possible

For communications with general-purpose RS232C devices
The serial input/output is executed by sequence commands

1ch

1ch

1ch

2ch

1ch
1ch
1ch

2ch

2ch

FP2-VE

FP2-ET1

AFPS32510

FP2-MW

FP2-MCU

FP2-CB232
FP2-CB422
FP2-CB485

FP2-CCU

FP2-SDU

Product number

Specification

Product name

FP2 MEWNET VE-link unit

FP2 ET-LAN unit

Control Configurator ET

FP2 Multi-wire link unit

FP2 Multi-communication unit

RS232C block
RS422 block
RS485 block
FP2 Computer 
communication unit

FP2 Serial data unit

FP2 FNS unit

1ch

FP2-FNS

Flexible Network Slave unit for FP2/FP2SH

PROFIBUS Plug-In Module

1ch

AFPN-AB6200

Plug-In network block for PROFIBUS

DeviceNet Plug-In Module

1ch

AFPN-AB6201

Plug-In network block for DeviceNet 

CANopen Plug-In Module

1ch

AFPN-AB6218

Plug-In network block for CANopen 

Serial communication and link-related intelligent units

Number of

channels

10Mbps, 8192 points/8192 words, 99 units max. (VE mode), 254 units max. (FL-net), 2500m

For FP2SH only (Cannot be used for FP2)

Ethernet-compatible unit for FP2/FP2SH

To be mounted on the CPU backplane
ET-LAN unit setting software (English)

For PLC links

Compatible with MEWNET-W/MEWNET-W2

Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks.

General-purpose serial communications, computer links, PLC links (MEWTNET-W0)

(For the multi-communication unit) 230kbps, 15m max.

(For the multi-communication unit) 230kbps, 1200m max.

(For the multi-communication unit) For PLC links (MEWNET-W0): 115kbps, 16 stations, 1,200m

For 1:1 communication between a PLC and a computer

RS232C x 2 ch Connection with a control panel is also possible

For communications with general-purpose RS232C devices
The serial input/output is executed by sequence commands

1ch

1ch

1ch

2ch

1ch
1ch
1ch

2ch

2ch

FP2-VE

FP2-ET1

AFPS32510

FP2-MW

FP2-MCU

FP2-CB232
FP2-CB422
FP2-CB485

FP2-CCU

FP2-SDU

Product number

Specification

Product name

FP2 MEWNET VE-link unit

FP2 ET-LAN unit

Control Configurator ET

FP2 Multi-wire link unit

FP2 Multi-communication unit

RS232C block
RS422 block
RS485 block
FP2 Computer 
communication unit

FP2 Serial data unit

FP2 FNS unit

1ch

FP2-FNS

Flexible Network Slave unit for FP2/FP2SH

PROFIBUS Plug-In Module

1ch

AFPN-AB6200

Plug-In network block for PROFIBUS

DeviceNet Plug-In Module

1ch

AFPN-AB6201

Plug-In network block for DeviceNet 

CANopen Plug-In Module

1ch

AFPN-AB6218

Plug-In network block for CANopen 

FP2-MW

FP2-C1SL

FP2-SL2

Number of I/O points

Not insulated Voltage: 1 to 5V, -10 to +10V Current: 4 to 20mA, -20 to +20mA
Insulated Voltages, currents, thermocouples, resistance thermometer devices
R.T.D. type: Pt 100, JPt 100, JPt 1000 type
Voltage range: -10 to +10V   Current range: 0 to 20mA   Resolution: 1/4096

Transistor

Line drive

2, independent
4, independent
2, independent
4, independent

2
4
8

Tool software for positioning unit RTEX (English)

FP2-PN2AN
FP2-PN4AN
FP2-PN8AN

AFPS66510

1pps to 500kpps

1pps to 4Mpps

FP2-PP21
FP2-PP41
FP2-PP22
FP2-PP42

FP2-HSCT

FP2-HSCP

FP2-PXYT

FP2-PXYP

NPN output

PNP output

NPN output

PNP output

FP2-DA4

Number of

channels

10Mbps, 8192 points/8192 words, 99 units max. (VE mode), 254 units max. (FL-net), 2500m

For FP2SH only (Cannot be used for FP2)

Ethernet-compatible unit for FP2/FP2SH.

To be mounted on the CPU backplane
ET-LAN unit setting software (English)

For PLC links

Compatible with MEWNET-W/MEWNET-W2

Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks.

General-purpose serial communications, computer links, PLC links (MEWTNET-W0)

(For the multi-communication unit) 230kbps, 15m max.

(For the multi-communication unit) 230kbps, 1200m max.

(For the multi-communication unit) For PLC links (MEWNET-W0): 115kbps, 16 stations, 1,200m

For 1:1 communication between a PLC and a computer

RS232C x 2 ch Connection with a control panel is also possible

For communications with general-purpose RS232C devices
The serial input/output is executed by sequence commands

1ch

1ch

1ch

2ch

1ch
1ch
1ch

2ch

2ch

FP2-VE

FP2-ET1

AFPS32510

FP2-MW

FP2-MCU

FP2-CB232
FP2-CB422
FP2-CB485

FP2-CCU

FP2-SDU

FP2-AD8VI
FP2-AD8X
FP2-RTD

FP2-AD8VI

FP2-AD8X

FP2-RTD

Product number

Controllable I/O points

Product number

Product number

Product number

Specification

Specification

Specification

Specification

Product name

Product name

Product name

Product name

FP2 Multi-wire link unit

FP2 CPU unit with S-LINK

FP2 S-LINK unit

Can connect as the remote I/O system MEWNET-F master station

Perfect for remote I/O systems using many points

Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system

CPU unit with 128 points x 2 channels

Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system

CPU unit with 128 points x 2 channels 

Max. 2048 points per one unit

256 points at S-LINK section

128 points per one unit

FP2 Positioning unit RTEX

Control Configurator PM

FP2 Positioning unit 
Multiifunction type

FP2 High-speed counter unit

FP2 Pulse I/O unit

FP2 MEWNET VE-link unit

FP2 ET-LAN unit

Control Configurator ET

FP2 Multi-wire link unit

FP2 Multi-communication unit

RS232C block
RS422 block
RS485 block
FP2 Computer 
communication unit

FP2 Serial data unit

Output type

Number of axes controlled

Speed command

8 interrupt inputs   4-channel high-speed counter   8 comparison outputs

Input: 24VDC   Output: 5 to 24VDC (0.1A, 12 points/0.8A, 4 points)

8 interrupt inputs   4-channel high-speed counter   8 comparison outputs

4 pulse output channels   4 PWM output channels

Input: 24VDC   Output: 5 to 24VDC (0.1A, 12 points/0.8A, 4 points)

FP2 Analog 
input unit

FP2 Analog output unit

Analog input: 8 channels
Analog input: 8 channels
R.T.D. input:  8 channels
Analog input: 4 channels

Notes:   1) Pressure welding socket is supplied. A special tool (part no. AXY52000) is needed for connection. Please purchase separately if you are using a terminal or flat 

    cable socket.
2) Please refer to “FP

3

 (Sigma) Product Types” for Motor driver I/F terminal II.

3) Previous FP2 positioning units FP2-PP2 and FP2-PP4 are not compatible with the multi-function type FP2 positioning unit.

3)

            A

A

A

A

            N/A

A

A

A

            N/A

A

A

A

            N/A

A

A

A

            A

A

A

A

A

A

A

            A

A
A

A
A

A
A

A
A

A

N/A

A

N/A

FPWIN Pro
for Windows 

FPWIN Pro
for Windows 

Full version with English manual

Full version with German manual

Full version with French manual

Small version with English manual

Small version with German manual

Small version with French manual

English: Full type

English: Small type

FPWINPROFEN5
FPWINPROFDE5
FPWINPROFFR5
FPWINPROSEN5
FPWINPROSDE5
FPWINPROSFR5

CD-ROM for Windows
CD-ROM for Windows

A: Available, N/A: Not available

A: Available, N/A: Not available

*1 FP1, FP-M, and FP3/FP10SH have been discontinued.

FPWIN Pro PLC programming software according to IEC 61131-3

FP2/FP2SH

Product Types

09/2007

Summary of Contents for FP2 Series

Page 1: ...FP2 FP2SH Series Programmable Controllers 09 2007...

Page 2: ...r cost performance Standard type FP2 C1 With 64 input points FP2 C1D With S LINK FP2 C1SL 60k step standard type FP2 C2 60k step type for small PC card FP2 C2P 120k step type for small PC card FP2 C3P...

Page 3: ...s program memory or expanded data memory I O point expansion by adding backplanes See page 14 for details Optional memory for FP2SH CPU backplane H type backplane Up to three backplanes can be added t...

Page 4: ...Controls up to 256 axes adequately supporting large scale equipment control Up to 32 eight axis units can be connected and up to 256 axes controlled when using FP2SH with H type backplane Selectable...

Page 5: ...can control up to 4 axes Stepping motor Servomotor Motor driver Motor driver Motor driver Motor driver High speed counter units and pulse I O units Interrupt counting pulse output and PWM output func...

Page 6: ...channels Industry s fastest level High speed achieved by highly reliable isolation among channels Temperature conversion 20ms ch Voltage conversion 5ms ch Without insulation setting 500ms ch Industry...

Page 7: ...rformance PLC FP Sigma and FP X can be established by using a combination of the multi communication unit and an RS485 communication block This mode enables the efficient connection of FP2 FP2SH FP Si...

Page 8: ...DB9F 9 pin Sub D female PROFIBUS Plug in module AFPN AB6 00 Various types of plug in network blocks can be mounted in the device at any phase between manufacturer and end customer without having to w...

Page 9: ...l Password protection IP lock security RS232C device server Ethernet RS232C conversion MEWTOCOL Transparent RS232C data tunneling via Ethernet Programming and visualization via TCP or UDP Modem dial o...

Page 10: ...F mode FP I O terminal board FP0 control unit FP0 I O link unit FP control unit FP0 I O link unit FP I O terminal unit Manifold solenoid valve S LINK S LINK is a link system that allows the free layou...

Page 11: ...r commercially available PC Display panel Remote monitoring via a modem Modem Public line Modem Commercially available cable Special cable available from Panasonic FP2 PCWAY for easy data collection T...

Page 12: ...oints 1024 points in total 6000 words Analog I O High speed counter Pulse output RS232C port Serial Available by adding analog input and analog output units Available by adding high speed counter unit...

Page 13: ...Remote I O PLC Link Computer Link Modem connection Program block edit during RUN Constant scan Clock Calendar function 100V to 120VAC 200V to 240VAC 100V to 240VAC 24VDC varies with different models 1...

Page 14: ...With S LINK FP2 C1SL Standard type 60k steps FP2 C2 Expansion cable 60cm FP2 EC Expansion cable 2m FP2 EC2 Dummy unit FP2 DM For small PC card 60k steps FP2 C2P For small PC card 120k steps FP2 C3P 24...

Page 15: ...nt PNP transistor output FP2 Y64P 32 point input 32 point NPN output mixed FP2 XY64D2T FP2 XY64D7T 32 point input 32 point PNP output mixed FP2 XY64D2P FP2 XY64D7P FP2 EM1 FP2 EM2 FP2 EM3 FP2 EM6 FP2...

Page 16: ...utput variables are defined once in the global variable list Multiple address assigment is caught automatically by the compiler Type safe programming using simple or complex data types Functions can b...

Page 17: ...exchanged using a CSV file An icon or tool tip notifies the user about possible errors in configuration The FP OPC Server allows you to clearly structure your application e g by grouping elements in m...

Page 18: ...2ms or less 32 point DC input type FP2 X32D2 24VDC Approx 4 3mA at 24VDC Approx 5 6k 19 2V 4mA 5 0V 1 5mA 0 2ms or less 0 3ms or less 64 point DC input type FP2 X64D2 24VDC Approx 4 3mA at 24VDC Appr...

Page 19: ...be actuated simultaneously is limited by the input voltage and the ambient temperature The maximum load current is limited by the external power supply voltage 1 The current capacity of each common te...

Page 20: ...Output range digital input Resolution Conversion speed Overall accuracy Insulation method Analog output Analog output unit FP2 DA4 4 channels 10V K 2048 to K 2047 0 to 20mA K0 to K4095 1 4096 500 s ch...

Page 21: ...assing Floating master 1 master The number of input and output points for each channel can be selected by the switch in the unit body Input 0 32 64 96 128 points Output 0 32 64 96 128 points 24VDC 10...

Page 22: ...points Output 0 32 64 96 128 points 24VDC 10 Maximum allowable ripples P P 10 S LINK terminal block IN 24VDC 1 6 A or less Current consumption of the S LINK controller incl D G line current consumptio...

Page 23: ...eration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption at 5 VDC External power Command units Max pulse count Command ran...

Page 24: ...C 0 1A 12 to 24VDC 50mA 5VDC FP2 X16D2 FP2 X32D2 FP2 X64D2 FP2 Y6R FP2 Y16R FP2 Y16T FP2 Y32T Note Please refer to FP Sigma Product Types for FP Memory Loader Notes 1 For FP2 CPU unit the capacity can...

Page 25: ...Specification Specification Product number Product number Product number Product name Product name Product name Note Pressure welding socket is supplied A special tool part number AXY52000 is needed f...

Page 26: ...k for DeviceNet CANopen Plug In Module 1ch AFPN AB6218 Plug In network block for CANopen Number of I O points Not insulated Voltage 1 to 5V 10 to 10V Current 4 to 20mA 20 to 20mA Insulated Voltages cu...

Page 27: ...tional 7 module type backplane Mounting dimension Tolerance 1 0 in mm Conventional backplanes 5 module 7 module 9 module 12 module 14 module L1 mm 140 209 265 349 405 L2 mm 130 199 255 339 395 H type...

Page 28: ...ic Electric Works Italia s r l Building Materials Division Piazza della Repubblica 24 20154 Milano MI Tel 02 29005391 Fax 02 29003466 Nordic Countries Panasonic Electric Works Nordic AB PEW Fire Secur...

Reviews: