IEC 60870 Functions of the FP Web-Server
FP Web-Server V2.11
152
13.1 IEC 60870 General Functions
The following connections to the FP Web-Server are possible:
1. The PLC is connected to the FP Web-Server via a 3-pin RS232C up to 115200 bps (see
PLC connection to the FP Web-Server (see page 162)).
2. IEC 60870-5-101 Unbalanced Communication (9-pin RS232C of the FP Web-Server
unit)
- directly via RS232C to the central station
- Multipoint via C-Net (RS485) adapter (AFP8536) up to 19200 bps
- Multipoint via FP Modem-EU (V.23 via twisted pair cable) with 1200 bps
- PSTN modem dialup connection (extension specified by OHP). This connection
receives calls from and/or dials out to the central station. Analog modem, ISDN
adapter or GSM module can be used.
3. IEC 60870-5-104 communication (via RJ45 Ethernet connector of the FP Web-Server
unit)
- via Ethernet
- TCP/IP communication also possible via PPP-Server and dialup modem
connections
Comment:
If an IEC 60870-5-104 Ethernet connection is established from the central station to the FP
Web-Server, an IEC 60870-5-101 connection via RS232C is impossible. As soon as there is no
Ethernet connection, the IEC 60870-5-101 connection can be established via RS232C again.
•
Using IEC 60870 communication the PLC needs to execute special IEC 60870
function blocks. These PLC function blocks are delivered as an FPWIN Pro
library together with the FP WEB Configurator Tool. The IEC 60870 FPWIN
Pro library, accompanying examples and interoperability documentation can
be installed from the FP WEB Configurator Tool CD-ROM. For details refer to
the Library's online help (see page 156).
•
If the IEC 60870 functions are to be used (checkbox "Enable IEC60870" is
active), disable standard FP Web-Server's functions like http, email, PPP
server or port function (see page 104). If these standard functions are
enabled at the same time as the IEC 60870 protocol, the reaction time and
performance of the FP Web functions may slow down.
•
If the 9-pin RS232C port is set up for IEC60870-5-101 communication,
MEWTOCOL communication can take place. The IEC60870 polling from the
central station must be stopped before MEWTOCOL communication can be
used. MEWTOCOL commands are sent directly to the PLC. This version only
allows short (standard) MEWTOCOL commands.
Summary of Contents for FP Web-Server
Page 3: ......
Page 11: ......
Page 12: ...Chapter 1 Getting Started...
Page 21: ...Getting Started FP Web Server V2 11 10 1 6 FP Web Server Block Diagram...
Page 23: ......
Page 24: ...Chapter 2 Hardware Description...
Page 41: ......
Page 42: ...Chapter 3 First Steps...
Page 55: ......
Page 56: ...Chapter 4 Configurator Software...
Page 61: ......
Page 62: ...Chapter 5 Base Configuration...
Page 66: ...Chapter 6 Email Setup...
Page 80: ...Chapter 7 Http Server Functions Web Pages...
Page 113: ......
Page 114: ...Chapter 8 Ethernet RS232C Ports...
Page 119: ......
Page 120: ...Chapter 9 Dial In Setup for PPP Server...
Page 125: ...Dial In Setup for PPP Server FP Web Server V2 11 114...
Page 127: ...Dial In Setup for PPP Server FP Web Server V2 11 116...
Page 139: ......
Page 140: ...Chapter 10 Dial Out Setup for PPP Client...
Page 150: ...Chapter 11 NTP Server for PLC Clock Synchronization...
Page 153: ......
Page 154: ...Chapter 12 Modbus Functions...
Page 162: ...Chapter 13 IEC 60870 Functions of the FP Web Server...
Page 168: ...Chapter 14 Java Applet Library MEW JAR...
Page 170: ...Chapter 15 Additional Information...