34
Troubleshooting
If a problem has occurred, investigate it by referring first to the table below. If the problem still
persists, please disconnect the power plug and contact the dealer for a check or repair.
Symptom
Please check the following:
The clean sign remains red even
when the operation continues.
●
The indicator may illuminate red when the product is exposed to
steam in the bathroom or vapor emitted from sprayers.
●
Are there external dusts such as yellow sand entering the room?
●
Is the dirt sensor dirty? (P.20)
Automatic operation cannot be
stopped.
●
Under the setting of [Auto] or [Silent], even if the dirt is not detected,
the product will operate corresponding to the ambient humidity.
The clean sign remains blue even
when the air is dirty.
●
Is the dirt sensor dirty? (P.20)
Polluted air is difficult to be
removed.
●
Is the 2 in 1 HEPA composite and deodorizing filter dirty? (P.20)
→
Clean it. If the symptom persists, replace it with the new one.
The air volume is small.
●
Is the 2 in 1 HEPA composite and deodorizing filter or the humidifying
filter dirty? (P.20, 24)
→
Clean them. If the symptom persists, replace them with the new
ones.
The odor from the product is
unpleasant.
●
Is the main body, the front panel or the 2 in 1 HEPA composite and
deodorizing filter dirty?
→
Clean them. If the symptom persists, replace the 2 in 1 HEPA
composite and deodorizing filter with the new one. (P.20)
●
Is the tray or the humidifying filter dirty? (P.22, 24)
●
Is water in the tray replaced with fresh tap water every day? (P.8)
●
In “Clean air” mode (without humidifying), empty the tray.
●
If the product is used in a room where people smoke or barbecue, a
shorter replacement cycle of filters may be required. (P.20)
→
When the product is used in such environment, we recommend
that you use the ventilation system of the room simultaneously.
The water amount in the tray
does not decrease.
While the humidifying indicator
is lit, the product does not
humidify.
●
Is the humidifying filter dirty? (P.24)
●
Does the humidity indicator indicate [Hi]?
→
In the [Auto] setting, the product will stop humidifying to keep
appropriate humidity, when [Hi] is on.
●
Is the tray installed completely?
●
Is the humidifying filter installed properly? (P.24)
→
When the humidifying filter is installed incorrectly, the product will
sound abnormally, and not humidify.
The humidity does not increase.
●
Is the room size too large for the product?
●
Is the room ventilated or having a carpet on the floor?
→
A carpet floor or some types of ventilation and floor/wall materials
may prevent smooth humidification.
There is condensation inside the
tray.
●
Immediately after the product stops operation or when the room is
cold, there may be condensation. This is normal.