5. Troubleshooting Guide

F-PXL45H

CAUTION

Symptom

Cause

Troubleshooting

Without

Energization

1,The machine’s power supply is

abnormal.

2,The PCB assembly may fail.

1,Check the power supply status and

check if the related wiring connection

is loosed.

2,Replace the PCB assembly.

The motor does

not operate or

speed is lower

than normal

levels

1,The motor assembly may fail.

2,The component on the PCB is

abnormal.

1,Replace the motor assembly.

2,Replace the PCB assembly.

The air volume

is small

1,Is the HEPA Composite Filter Assembly

dirty.

1,Clean it.If the symptoms persist,

replace the filter a new one.

Polluted air is

difficult to be

removed

1,Is the HEPA Composite Filter Assembly

dirty.

1,Clean it.If the symptoms persist,

replace the filter a new one.

The odor from

the unit is

unpleasant

1,Is the main unit,the front panel or the

filter dirty.

2,Has it ever used in a room with strong

smells

1,Clean it. If the symptoms persist,

replace the filter with a new one.

2,If the unit is used in a room where

people smoke or barbecue,a shorter

replacement cycle of filters may be

required

Disconnect power source before working on the unit to avoid receiving an electric shock.

Summary of Contents for F-PXL45H

Page 1: ...service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety These parts are marked by in the Schematic Diagrams Exploded Views and Replacement Parts List It is essential that these critical parts should be replaced wi...

Page 2: ...1 Specifications 1 F PXL45H ...

Page 3: ...a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a ...

Page 4: ...ion 2 Parts Identification F PXL45H Front Case Seciton 15 18 16 B 3pcs 17 19 B 3pcs 20 21 23 22 24 A 3pcs 26 28 30 25 27 29 31 2pcs 32 33 34 36 37 35 B 3pcs C 5pcs C 3pcs 40 43 41 B 4pcs 42 38 39 Front Case Section ...

Page 5: ...4 2 Parts Identification Nanoe Assembly F PXL45H Power Circuit Section 51 52 A 2pcs 53 55 56 54 44 45 46 47 48 50 49 ...

Page 6: ... a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a 61 Packing Section 64 2pcs ...

Page 7: ...6 2 Parts Identification F PXL45H Optional Accessories 66 68 69 67 70 Panasonic ...

Page 8: ... 4 B G CN1 CN2 Magnet Core CN101 CN102 CN103 CN107 CN106 CN105 CN401 CN5 CN2 CN1 CN4 CN6 CN3 CN104 1 3 CN301 3 1 1 10 Main Circuit Assembly 220V 50Hz Motor Assembly Dust Sensor Nanoe PCB Assembly Nanoe Unit Clean Circuit Assembly Remote Control Circuit Assembly Odor Circuit Assembly Switch Circuit Assembly ...

Page 9: ...ter Hook Label 1 Stuck On Front Case Assembly 13 FFE00771501S Filter Label 1 Stuck On Front Case Assembly 14 FFE00501504S Name Plate 1 Stuck On Rear Case No Part No Part Name Q ty Remark 15 FFE09021501S Dust Sensor Lead 1 16 FFE12501501S Dust Sensor 1 17 FFE49501501S Clean Circuit Assembly 1 18 FFE12231501S Clead PCB Lead 1 19 FFE01101501S Main Frame 1 20 FFE08110801S Holder Gum A 1 21 FFE23001501...

Page 10: ... 1 43 FFE04121503S Switch Panel 1 B XTB4 14CFJ Bind Tap Screw 8 C XTN35 10CFJ Pan Tap Screw 7 No Part No Part Name Q ty Remark 44 FFE01211501S Nanoe Cover 1 45 FFE09051501S Nanoe Lead 1 46 FFE09071501S Peltier Lead 1 47 FFE48041301S Nanoe PCB Assembly 1 48 FFE09061301S High Voltage Lead 1 49 FFE15001302S Nanoe Unit 1 50 FFE01191501S Nanoe Case 1 No Part No Part Name Q ty Remark 51 FFE01131501S Pow...

Page 11: ...S Poly Cover 1 For Deodorizing Filter Assembly Packing 62 FFE89501504S Instructions 1 63 FFE21401101S Poly Cover 1 For Main Body Packing 64 FFE01110801S Poly Cover 2 For Cord Assembly Packing 65 FFE80011506S Carton Case 1 No Part No Part Name Q ty Remark 66 FFE34281501S Holder 1 67 FFE34271501S Hanger 1 68 FFE86101501S Screw Set 1 69 FFE09081501S Remote Control Assembly 1 70 FFE02401501S Installat...

Page 12: ...s small 1 Is the HEPA Composite Filter Assembly dirty 1 Clean it If the symptoms persist replace the filter a new one Polluted air is difficult to be removed 1 Is the HEPA Composite Filter Assembly dirty 1 Clean it If the symptoms persist replace the filter a new one The odor from the unit is unpleasant 1 Is the main unit the front panel or the filter dirty 2 Has it ever used in a room with strong...

Page 13: ...re terminal on the power circuit assembly Abnormal Rotating blade by hand and check the motor shaft lock In running condition to check the CN4 s 3 pin and 4 pin Terminal voltage Abnormal Normal Eliminate any blade contact or foreign object Motor rotating heavily Replace the motor assembly Abnormal Abnormal Replace the power circuit assembly Normal Run the machine Abnormal Replace the motor assembl...

Page 14: ...1 3 CN301 3 1 1 10 Main Circuit Assembly 220V 50Hz Motor Assembly Dust Sensor Nanoe PCB Assembly Nanoe Unit Clean Circuit Assembly Remote Control Circuit Assembly Odor Circuit Assembly Switch Circuit Assembly GND 5V GND 5V GND 15V 15V 5V GND L N Vdc 310V FG GND Vsp 15V 5V GND 15V GND The output voltage of the circuit assembly terminal is used for checking when machine detected CN4 CN2 CN6 ...

Page 15: ...14 5 Troubleshooting Guide F PXL45H Setting method of checking mode ...

Page 16: ...Setting method of checking mode 15 5 Troubleshooting Guide F PXL45H ...

Page 17: ...Setting method of checking mode 16 5 Troubleshooting Guide F PXL45H ...

Page 18: ...Setting method of checking mode 17 5 Troubleshooting Guide F PXL45H ...

Page 19: ...Setting method of checking mode 18 5 Troubleshooting Guide F PXL45H ...

Page 20: ...e is used to check the working status of all features of the machine Indicator Light s Notes 1 Function icon Black is light off color is light on 2 Rectangular bar is air pollution indicator Display color includes blue pink red Colorless is light off 1 2 3 3 In red dot scope Indicator Light Flashing ...

Reviews: