Area Ionizer 

ER-X

 

SERIES

Carefully designed to prevent 

contamination in manufacturing processes

In consideration of the manufacturing process 

(secondary cells etc.), the 

ER-X

 series heads neither 

use copper nor plate processing. This minimizes the risk 

of contamination with foreign substances.

Discharge needle air barrier design for reduced contamination

A barrier of clean air around the discharge needle keeps 

foreign matter from adhering to it, preventing degraded 

performance. Additionally, by using separate air sources 

for the discharge needle barrier and ion transport, the 

ER-X

 series keeps discharge from becoming unstable 

due to pressure concentration, allowing the device to 

efficiently generate and transport ions.

Air barrier 

structure

Efficient charge 

removal structure

Discharge needle after 

protected by air barrier 

(0.05 MPa) for one month

Flat discharge surface for easy cleaning

The 

ER-X

 series heads have a flat discharge face, 

allowing effortless cleaning of the discharge needles and 

air outlets by simply brushing along the groove provided.

Commercial brush

Groove

Discharge needles

Air outlets

Discharge needle unit for simple needle replacement

The removable discharge needle unit (including a set 

of four needles) substantially simplifies maintenance. 

To remove the unit, just slide it toward both ends as 

indicated by the arrows.

Discharge needle unit

High and low temperature resistant type head also available

ER-X□HC

Bar type head compatible with ambient temperatures of 

-60 to +200 °C 

-76 to +392 °F

 is available.

BAR TYPE HEAD

ER-X008

Effective charge removal width: 

80 mm 

3.150 in

 approx.

ER-X016

Effective charge removal width:

160 mm 

6.299 in

 approx.

ER-X032

Effective charge removal width:

320 mm 

12.598 in

 approx.

ER-X048

Effective charge removal width:

480 mm 

18.898 in

 approx.

ER-X064

Effective charge removal width:

640 mm 

25.197 in

 approx.

Super-compact slim head

By thoroughly redesigning the discharge needle, we 

have created a super-compact slim head that combines 

high-speed charge removal*

1

 with a maintenance-saving 

design*

2

. The 

ER-X

 series can be embedded in, or 

retrofitted onto, equipment that did not provide enough 

space for antistatic measures in the past.

*1: Pulse AC method with built-in air tubes (max. pressure 0.5 MPa)
*2:  Discharge needle air barrier structure, discharge needle unit for 

simple need replacement

360-

degree 

angle 

adjustment

360-

degree 

angle 

adjustment

30 mm

30 mm

(1.181 in)

(1.181 in)

22 mm

22 mm

(0.866 in)

(0.866 in)

Angle adjustment screw

Summary of Contents for ER-X Series

Page 1: ...2022 7 Pulse AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Area Ionizer ER XSERIES...

Page 2: ...plying a compressed air source the ion volume increases providing an improved tact time for substrate ionization This makes the ER X suitable for applications such as electronic paper and thin film so...

Page 3: ...es the amount of ions being generated which changes according to environmental factors and compensate for this deviation in the controller thus maintaining a highly stable ion balance as an original o...

Page 4: ...simple needle replacement The removable discharge needle unit including a set of four needles substantially simplifies maintenance To remove the unit just slide it toward both ends as indicated by the...

Page 5: ...e ion generation timing for the two heads to synchronize or inverse Error output changeover switch Set the error output condition to generation of abnormal discharge or generation of abnormal discharg...

Page 6: ...h speed charge removal on a taping machine Prevention of part feeder clogging Charge removal of molded plastic components on a conveyor belt Removing dust during food product cup transport Airlesschar...

Page 7: ...nce 50 mm 1 969 in center of the product discharge frequency 50 Hz and air supply 60 min 0 3 MPa 2 Typical value in condition of discharge distance 100 mm 3 937 in ER X001 50 mm 1 969 in center of the...

Page 8: ...orming to CCC Length 2 m 6 562 ft CN ACKR C2 AC cable conforming to KTL Length 2 m 6 562 ft Discharge needle unit ER XANT For ER X016 X032 X048 X064 Note 2 Unit with replacement tungsten needles 1 pc...

Page 9: ...e generation 0 01 ppm or less Note 2 Maximum air pressure 0 1 MPa Applicable fluid Air dried clean air Note 5 Operating altitude 2 000 m 6561 68 ft or less Note 6 Ambient temperature Head 60 to 200 C...

Page 10: ...to 65 RH Storage 35 to 85 RH Voltage withstandability 1 000 V AC for one min between all supply terminals connected together and enclosure 500 V AC for on min between supply terminals and F G Insulati...

Page 11: ...0 200 7 874 400 15 748 600 23 622 800 31 496 1 000 39 370 Charge removal distance L mm in Charge removal time sec 2 4 6 8 10 L CPM Center Common to ER X001 X008 ER X001 Charge removal field airless 50...

Page 12: ...z 1 600 62 992 1 400 55 118 1 200 47 244 1 000 39 370 800 31 496 600 23 622 400 15 748 200 7 874 0 200 7 874 100 3 937 300 11 811 100 3 937 200 7 874 500 19 685 300 11 811 400 15 748 400 15 748 500 19...

Page 13: ...W CPM Center 600 23 622 300 11 811 400 15 748 200 7 874 500 19 685 100 3 937 0 Charge removal width W mm in Charge removal distance L mm in 400 15 748 200 7 874 200 7 874 400 15 748 800 31 496 600 23...

Page 14: ...1 sec 2 sec Charge removal field vertical direction 0 5 MPa 50 Hz 0 L W CPM Center 1 600 62 992 800 31 496 1 000 39 370 400 15 748 600 23 622 200 7 874 1 400 55 118 1 200 47 244 Charge removal width W...

Page 15: ...ification of previous type and new type controllers and for the combination with the head refer to p 16 COM White COM IN Violet COM OUT Orange Alarm output Black Error output Pink Discharge control in...

Page 16: ...rify that the supply voltage variation is within the rating In case using switching regulator be sure to connect F G terminal When connecting removing the head or performing wiring or inspection work...

Page 17: ...ltage units 3 When fastening the high voltage unit using M6 screws fasten before connecting the head connection cable 4 Use M6 screws for the installation of the high voltage unit of the ER X001 5 The...

Page 18: ...6 35 1 378 25 0 984 2 6 5 0 256 mounting holes 2 4 5 0 177 mounting holes 17 0 669 12 0 472 6 0 236 28 4 1 118 180 7 087 170 6 693 162 6 378 192 7 559 160 6 299 18 0 709 18 0 709 12 pin connector DIME...

Page 19: ...0 874 5 3 0 209 L Model No Length L ER XCC2 2 000 78 740 ER XCC5 5 000 196 850 Length L ER XAPS EX AC adapter Optional 22 2 0 874 19 6 0 772 Cable 1 8 m 5 910 ft F G wire 3 7 m 12 139 ft AC cable 1 8...

Page 20: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...

Reviews: