Area Ionizer 

ER-X

 

SERIES

17

PRECAUTIONS FOR PROPER USE

Notes: 1)  Be sure to ground the equipment housing onto which the head is 

mounted.

2)  The distance between the head and the charge removing object 

should be 30 mm 

1.181 in

 or more. 

If the static buildup of the charge removing object is 30 kV or more, 

set the distance to 50 mm 

1.969 in

 or more.

3)  If there is metal near the head or between the head and the charge 

removing object, ion is absorbed, hindering appropriate static 

removal. Install the head under the following installation condition.

4)  In case using the side mounting, the discharge frequency should 

be 10 Hz or more.

5)  When installing two or more heads set the same frequency and 

keep the distance as below. In face to face or parallel using 

different frequency, keep the distance between the heads 400 mm 

15.748 in

 or more. 

When installing the heads face to face, install heads in distance 

that the heads can perform the charge removal of a side of the 

object individualy. 

• Using two M4 screws or one M6 screw,

mount the head onto the equipment housing.

• Loosen the angle adjustment screw,

adjust the head angle, and then fasten the

head with the tightening torque of 0.5 N∙m

or less.

• Position the head mounting bracket of the

ER-X001

 at least 20 mm 

0.787 in

 away

from the tip of the head. The tightening

torque for the head fixing screw must be

0.5 N∙m or less.

• After mounting and setting up the head,

set the controller according to the procedures described in the

instruction manual in order to properly remove electrical charge.

Mounting

M6 

screw

Angle 

adjustment screw

M4 

screw

Angle 

adjustment screw

Surrounding

metal

• Back-side mounting (All frequencies)

50 mm

1.969 in

 or more

 

• Side mounting (10 Hz or more)

50 mm

1.969 in

 or more

Surrounding

metal

• Mounting of 

ER-X001

20 mm 

0.787 in

 

or more

20 mm 

0.787 in

 

or more

The discharge 

muzzle must 

exceed this line

(surrounding metal.)

Head installation

Notes: 1)  Do not place any objects on top of the 

high-voltage unit.

2)  When using multiple heads, keep the 

distance of at least 10 mm 

0.394 in

 

between the high-voltage units. 

3)  When fastening the high-voltage 

unit using M6 screws, fasten before 

connecting the head connection cable.

4)  Use M6 screws for the installation of the high-voltage unit of the 

ER-X001

.

5)  The minimum bending radius of the high-voltage cable is R30 mm 

R1.181 in

.

M4 screw

10 mm

0.394 in

or more

M6 screw

• Use two M4 screws or two M6 screws

to fasten the head. The tightening

torques for fastening, are as follows.
• When using M4 screws: 1.2 N∙m
• When using M6 screws: 2.5 N∙m

High-voltage unit installation

Controller installation

<When mounting on a DIN rail>

• Pull the lock release lever to

remove this product from the

DIN rail.

<When mounting using M4 screws>

• The tightening torque should be

1.2 N∙m or less.

• Mount the controller on a 35 mm 

1.378 in

 width DIN rail or using

M4 screws.

35 mm 

1.378 in

 

width DIN rail

Lock release lever

M4 screw

• Air supplied to this product will reduce contamination of the

discharge needle and improve the charge removal speed.

The outer diameter of the air tube to fit to the air inlet portion of

this product should be ø6 mm 

ø0.236 in

.

• Make sure that clean air (air containing no water, no oil and no

dust) should be supplied.

• Since the pressure will drop when the air piping from the main

pressure supply is extended or pneumatic components (e.g.,

needle valve, speed controller, mini filter) are added, keep an

eye on the pressure supply to the ionizer making sure it is not in

short supply. For the pneumatic components, select those that

can accommodate the air supply flow rate.

Piping

Note:   After inserting the tube into the joint of this product, always make sure 

that the tube is all the way in and securely inserted. Insufficient tube 

insertion will cause air leakage.

Air inlet

ø6 mm 

ø0.236 in

 tube

Head section

11.4 mm 

0.449 in

ø6 

ø0.236

-4 air tube joint

Head section

ø6 mm 

ø0.236 in

 

heat-resistant tube

Insert all the way

• Face-to-face installation

• Parallel installation

ER-X008/X016/X032/X048/X064

ER-X008HC/X016HC/X032HC/X048HC/X064HC

ER-X001

<Connection of pipe to head section>

<Connection of pipe to head section>

<Connection to high-voltage unit>

M4 screw

Head 

fixing 

screw

100 mm

3.937 in

or more

100 mm

3.937 in

or more

50 mm 

1.969 in

or more

50 mm

1.969 in

or more

(11.6 mm 

0.457 in

)

High-voltage unit

Air inlet

ø6 mm 

ø0.236 in

 tube

Summary of Contents for ER-X Series

Page 1: ...2022 7 Pulse AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Area Ionizer ER XSERIES...

Page 2: ...plying a compressed air source the ion volume increases providing an improved tact time for substrate ionization This makes the ER X suitable for applications such as electronic paper and thin film so...

Page 3: ...es the amount of ions being generated which changes according to environmental factors and compensate for this deviation in the controller thus maintaining a highly stable ion balance as an original o...

Page 4: ...simple needle replacement The removable discharge needle unit including a set of four needles substantially simplifies maintenance To remove the unit just slide it toward both ends as indicated by the...

Page 5: ...e ion generation timing for the two heads to synchronize or inverse Error output changeover switch Set the error output condition to generation of abnormal discharge or generation of abnormal discharg...

Page 6: ...h speed charge removal on a taping machine Prevention of part feeder clogging Charge removal of molded plastic components on a conveyor belt Removing dust during food product cup transport Airlesschar...

Page 7: ...nce 50 mm 1 969 in center of the product discharge frequency 50 Hz and air supply 60 min 0 3 MPa 2 Typical value in condition of discharge distance 100 mm 3 937 in ER X001 50 mm 1 969 in center of the...

Page 8: ...orming to CCC Length 2 m 6 562 ft CN ACKR C2 AC cable conforming to KTL Length 2 m 6 562 ft Discharge needle unit ER XANT For ER X016 X032 X048 X064 Note 2 Unit with replacement tungsten needles 1 pc...

Page 9: ...e generation 0 01 ppm or less Note 2 Maximum air pressure 0 1 MPa Applicable fluid Air dried clean air Note 5 Operating altitude 2 000 m 6561 68 ft or less Note 6 Ambient temperature Head 60 to 200 C...

Page 10: ...to 65 RH Storage 35 to 85 RH Voltage withstandability 1 000 V AC for one min between all supply terminals connected together and enclosure 500 V AC for on min between supply terminals and F G Insulati...

Page 11: ...0 200 7 874 400 15 748 600 23 622 800 31 496 1 000 39 370 Charge removal distance L mm in Charge removal time sec 2 4 6 8 10 L CPM Center Common to ER X001 X008 ER X001 Charge removal field airless 50...

Page 12: ...z 1 600 62 992 1 400 55 118 1 200 47 244 1 000 39 370 800 31 496 600 23 622 400 15 748 200 7 874 0 200 7 874 100 3 937 300 11 811 100 3 937 200 7 874 500 19 685 300 11 811 400 15 748 400 15 748 500 19...

Page 13: ...W CPM Center 600 23 622 300 11 811 400 15 748 200 7 874 500 19 685 100 3 937 0 Charge removal width W mm in Charge removal distance L mm in 400 15 748 200 7 874 200 7 874 400 15 748 800 31 496 600 23...

Page 14: ...1 sec 2 sec Charge removal field vertical direction 0 5 MPa 50 Hz 0 L W CPM Center 1 600 62 992 800 31 496 1 000 39 370 400 15 748 600 23 622 200 7 874 1 400 55 118 1 200 47 244 Charge removal width W...

Page 15: ...ification of previous type and new type controllers and for the combination with the head refer to p 16 COM White COM IN Violet COM OUT Orange Alarm output Black Error output Pink Discharge control in...

Page 16: ...rify that the supply voltage variation is within the rating In case using switching regulator be sure to connect F G terminal When connecting removing the head or performing wiring or inspection work...

Page 17: ...ltage units 3 When fastening the high voltage unit using M6 screws fasten before connecting the head connection cable 4 Use M6 screws for the installation of the high voltage unit of the ER X001 5 The...

Page 18: ...6 35 1 378 25 0 984 2 6 5 0 256 mounting holes 2 4 5 0 177 mounting holes 17 0 669 12 0 472 6 0 236 28 4 1 118 180 7 087 170 6 693 162 6 378 192 7 559 160 6 299 18 0 709 18 0 709 12 pin connector DIME...

Page 19: ...0 874 5 3 0 209 L Model No Length L ER XCC2 2 000 78 740 ER XCC5 5 000 196 850 Length L ER XAPS EX AC adapter Optional 22 2 0 874 19 6 0 772 Cable 1 8 m 5 910 ft F G wire 3 7 m 12 139 ft AC cable 1 8...

Page 20: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...

Reviews:

Related manuals for ER-X Series