Area Ionizer
ER-X
SERIES
17
PRECAUTIONS FOR PROPER USE
Notes: 1) Be sure to ground the equipment housing onto which the head is
mounted.
2) The distance between the head and the charge removing object
should be 30 mm
1.181 in
or more.
If the static buildup of the charge removing object is 30 kV or more,
set the distance to 50 mm
1.969 in
or more.
3) If there is metal near the head or between the head and the charge
removing object, ion is absorbed, hindering appropriate static
removal. Install the head under the following installation condition.
4) In case using the side mounting, the discharge frequency should
be 10 Hz or more.
5) When installing two or more heads set the same frequency and
keep the distance as below. In face to face or parallel using
different frequency, keep the distance between the heads 400 mm
15.748 in
or more.
When installing the heads face to face, install heads in distance
that the heads can perform the charge removal of a side of the
object individualy.
• Using two M4 screws or one M6 screw,
mount the head onto the equipment housing.
• Loosen the angle adjustment screw,
adjust the head angle, and then fasten the
head with the tightening torque of 0.5 N∙m
or less.
• Position the head mounting bracket of the
ER-X001
at least 20 mm
0.787 in
away
from the tip of the head. The tightening
torque for the head fixing screw must be
0.5 N∙m or less.
• After mounting and setting up the head,
set the controller according to the procedures described in the
instruction manual in order to properly remove electrical charge.
Mounting
M6
screw
Angle
adjustment screw
M4
screw
Angle
adjustment screw
Surrounding
metal
• Back-side mounting (All frequencies)
50 mm
1.969 in
or more
• Side mounting (10 Hz or more)
50 mm
1.969 in
or more
Surrounding
metal
• Mounting of
ER-X001
20 mm
0.787 in
or more
20 mm
0.787 in
or more
The discharge
muzzle must
exceed this line
(surrounding metal.)
Head installation
Notes: 1) Do not place any objects on top of the
high-voltage unit.
2) When using multiple heads, keep the
distance of at least 10 mm
0.394 in
between the high-voltage units.
3) When fastening the high-voltage
unit using M6 screws, fasten before
connecting the head connection cable.
4) Use M6 screws for the installation of the high-voltage unit of the
ER-X001
.
5) The minimum bending radius of the high-voltage cable is R30 mm
R1.181 in
.
M4 screw
10 mm
0.394 in
or more
M6 screw
• Use two M4 screws or two M6 screws
to fasten the head. The tightening
torques for fastening, are as follows.
• When using M4 screws: 1.2 N∙m
• When using M6 screws: 2.5 N∙m
High-voltage unit installation
Controller installation
<When mounting on a DIN rail>
• Pull the lock release lever to
remove this product from the
DIN rail.
<When mounting using M4 screws>
• The tightening torque should be
1.2 N∙m or less.
• Mount the controller on a 35 mm
1.378 in
width DIN rail or using
M4 screws.
35 mm
1.378 in
width DIN rail
Lock release lever
M4 screw
• Air supplied to this product will reduce contamination of the
discharge needle and improve the charge removal speed.
•
The outer diameter of the air tube to fit to the air inlet portion of
this product should be ø6 mm
ø0.236 in
.
• Make sure that clean air (air containing no water, no oil and no
dust) should be supplied.
• Since the pressure will drop when the air piping from the main
pressure supply is extended or pneumatic components (e.g.,
needle valve, speed controller, mini filter) are added, keep an
eye on the pressure supply to the ionizer making sure it is not in
short supply. For the pneumatic components, select those that
can accommodate the air supply flow rate.
Piping
Note: After inserting the tube into the joint of this product, always make sure
that the tube is all the way in and securely inserted. Insufficient tube
insertion will cause air leakage.
Air inlet
ø6 mm
ø0.236 in
tube
Head section
11.4 mm
0.449 in
ø6
ø0.236
-4 air tube joint
Head section
ø6 mm
ø0.236 in
heat-resistant tube
Insert all the way
• Face-to-face installation
• Parallel installation
ER-X008/X016/X032/X048/X064
ER-X008HC/X016HC/X032HC/X048HC/X064HC
ER-X001
<Connection of pipe to head section>
<Connection of pipe to head section>
<Connection to high-voltage unit>
M4 screw
Head
fixing
screw
100 mm
3.937 in
or more
100 mm
3.937 in
or more
50 mm
1.969 in
or more
50 mm
1.969 in
or more
(11.6 mm
0.457 in
)
High-voltage unit
Air inlet
ø6 mm
ø0.236 in
tube