1
0
Area Ionizer
ER-X
SERIES
SPECIFICATIONS
Type
Controller
Item
Model No.
ER-XC02
CE marking directive compliance
EMC Directive, RoHS Directive
Number of heads connected
Maximum 2 units
Supply voltage
24 V DC ±10 %
Current consumption
450 mA or less when connecting 1 head, 800 mA or less when connecting 2 heads
Indicator
Displays status of Head 1 and 2
DSC (Discharge)
Green LED (lights up when discharging)
CHECK
Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected)
ERROR
Red LED (lights up when abnormal discharge is detected)
Level meter
Green LED (5 levels, lights up depending on amount of the charge or ion generation)
Output
ALARM
ERROR
COM (Common)
PhotoMOS relay output
• Maximum load current: 100 mA
•
Applied voltage: 30 V DC or less (between output-output common)
•
Residual voltage: 1.5 V or less (at 100 mA load current)
Output operation
ALARM: ON when dirt or wear of the discharge needle is detected, OFF when operation is normal.
ERROR: OFF when abnormal discharge is detected, ON when operation is normal.
Short-circuit protection
Incorporated (automatic reset type)
Discharge control input (DSC OFF)
Discharge allowed: Open, Discharge halt: 24 V or 0 V shorted
Contamination level
2
Overvoltage category
I
Elevation
2,000 m
6561.68 ft
or less (Note)
Ambient temperature
0 to +50 °C
+32 to +122 °F
(No dew condensation allowed), Storage: –10 to +65 °C
+14 to +149 °F
Ambient humidity
35 to 65 % RH, Storage: 35 to 85 % RH
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
500 V AC for on min. between supply terminals and F.G.
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 150 Hz frequency, 0.75 mm
0.030 in
double amplitude in X, Y and Z directions for two hours each
Shock resistance
100 m/s
2
acceleration (10 G approx.) in X, Y and Z directions three times each
Enclosure grounding method
Floating
Material
Enclosure: ABS
Weight
Net weight: 130 g approx.
Accessories
Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex])
Ground wire (3.7 m
12.139 ft
approx.): 1 pc.
Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Controller
Allowable ambient temperature of high and low temperature resistant type head ER-X□HC and its installation
When installing, make sure to expose a section measuring 500 mm
19.685 in
or more to the normal temperature area as
shown below for the protection of the high-voltage unit.
Note: The high and low temperature resistant type
ER-X□HC
cannot be connected with the
ER-XCCJ10H
head connection cable (10 m
32.808 ft
in length).
Allowable ambient temperature of the head
-60 to +200 °C
-76 to +392 °F
Allowable ambient temperature of the high-voltage unit
0 to +50 °C
+32 to +122 °F
Head connection cable (Note)
500 mm
19.685 in
or more
Head
High-voltage cable (1.8 m
5.906 ft
)
High-voltage unit