TEST AND MEASUREMENT
MCUK001002C8
Section 6
Issue 1
Service Manual
– 43 –
Revision 0
Calibration of output power on each power level
NOTE:
To ensure that the telephone operates within set SAR margins, Panasonic recommends that a power meter
capable of measurement to an accuracy of ±0.2 dB is used when calibrating power levels. Use of a less
accurate power meter may result in the telephone failing to meet SAR standards.
1.
Power on the telephone in Test Set Mode.
2.
Scroll down the menu until CHANGE CH <62> is highlighted and then press ENTER.
3.
Scroll down the menu until PL <5> is highlighted. Use the left and right cursor keys to select <14>. Press ENTER.
4.
Scroll down the menu until TX DATA <OFF> is highlighted. Using the left / right cursor keys, highlight <NRL R> and press
ENTER.
5.
At the power meter, measure the peak power.
6.
If measured power is in the range of the target power, then proceed to step 10.
7.
At the Channel box, press F7 to view the TRIM for the mid-channel.
Figure 6.14: Power level view 1
8.
Select VIEW TRIM PL MCH, and make a note of this value.
Figure 6.15: Power level 2
Summary of Contents for EB-GD93
Page 4: ...Issue 1 iv MCUK001002C8 Revision 0 Service Manual This page is left intentionally blank ...
Page 73: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 5 8 7 5 06 0DLQ 3 RJLF ...
Page 74: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Page 75: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Page 76: ...CIRCUIT DIAGRAMS MCUK001002C8 Section 8 Issue 1 Service Manual 71 Revision 0 8 4 Keypad PCB ...
Page 77: ......
Page 78: ... 287 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 287 5 06 0DLQ 3 A B C D E F 1 2 3 4 ...
Page 79: ... 287 5 06 VVXH 6HFWLRQ 0 8 5HYLVLRQ 6HUYLFH 0DQXDO H SDG 3 A B C D 1 2 3 4 5 ...