7.5 Adjustment Mode
NOTE:
See section 7.2.1 for a list of the equipment and setup procedures required to perform the following adjustment and
calibration procedures.
The following procedures MUST be performed after replacement or repair of one or both of the PCBs in the
handheld unit. Failure to do so may result in incorrect operation of the telephone.
The following adjustments MUST be made on BOARD PAIRS.
There are four distinct calibration procedures to adjust RF performance. These procedures are:
1.
Ramping gain (Section 7.5.1)
2.
RSSI (Section 7.5.2)
3.
I and Q values (Section 7.5.3)
The adjustment data selected during calibration is stored in the telephone EEPROM.
NOTE:
As G600 has two battery types available, Lithium Ion and Nickel Metal Hydride, all calibration procedures must be
carried out for each battery type.
Figure 10:
Test software screen
600-0721
7.5.1 Ramping Gain
The carrier power must be measured and calibrated for each power level at channel 62.
Target
Power Level
Peak Power
(dBm)
Tolerance
(dB)
Initial Calibration Value
Change per dB
4.8V
7.2V
4.8V
7.2V
PL5
33
±2
192
170
14.29
40.00
PL6
31
±3
157
150
12.50
20.00
PL7
29
±3
134
130
5.56
10.00
PL8
27
±3
118
116
7.69
7.14
PL9
25
±3
106
104
5.88
6.25
PL10
23
±3
96
94
5.00
5.26
PL11
21
±3
87
85
4.00
4.25
PL12
19
±3
117
115
5.00
5.00
PL13
17
±3
108
106
4.00
4.35
PL14
15
±3
101
99
3.45
3.57
PL15
13
±3
95
93
2.94
3.03
PL16
11
±5
90
87
2.56
2.63
PL17
9
±5
85
83
2.17
2.22
MCUK980101C8
Section 7
Issue 1
Service Manual
7 - 9
Revision
0
TEST AND MEASUREMENT