2.
Ensure that the following settings are made:
a)
Interface box IFB002
Power:
DOWN position
IGN:
DOWN position
HH/HF:
DOWN HH position
MODE:
UP position
b)
Power supply
+12V DC:
OFF
c)
PC
Channel box software loaded and the screen indicating as shown (figure 8):
Figure 8:
PC Screen (SCRN9)
600-0720
3.
On the PC press ENTER.
4.
Switch on the 12V supply.
5.
At the PC press F10.
6.
At the Interface box switch the POWER to ON.
Entering Call Mode from Test Mode
The screen of the PC will resemble the one shown in figure 8:
Figure 9:
PC Screen (SCRN11)
500-0721
1.
At the PC change the SOFT SIM field to read <ENB>. Press ENTER.
2.
At the PC change the TEST field to read <TERM>. Press ENTER.
The UUT will power down and up again. If the UUT is connected to a GSM test set, after a delay of
approximately 5 seconds the UUT will register service.
3.
To return to test mode, set SOFT SIM field to <DIS> and set TEST field to <Test>. Press ENTER.
Issue 1
Section 7
MCUK980101C8
Revision 0
7 - 6
Service Manual
TEST AND MEASUREMENT