90
Setup menus
(continued)
<INTERFACE>
The underlining (__) denotes the factory setting mode.
No./Item
Description of setting
200
PARA RUN
For selecting whether to operate two or more
VTRs in synchronization.
0000
DIS
The VTRs are not operated in synchronization.
0001
ENA
The VTRs are operated in synchronization.
<Note>
To operate the VTRs in synchronization, set all the
VTRs to 1 (ENA). (Refer to page 16.)
202
ID SEL
For setting what ID information is to be
returned to the controller.
0000
OTHER
For setting the ID information of a VTR other
than DVCPRO
0001 DVCPRO
For setting the ID information of the DVCPRO
0002
ORIG
Set only for connecting with the Panasonic
controller (AG-A850, optional).
204
RS2323C SEL
For selecting whether the RS-232C connector is
to function.
0000
OFF
The RS-232C connector does not function.
0001
ON
The RS-232C connector functions.
205
BAUD RATE
For setting the RS-232C data transfer speed
(baud rate).
0000
300
0001
600
0002
1200
0003
2400
0004
4800
0005
9600
206
DATA
LENGTH
For setting the RS-232C data length.
(Unit: bits)
0000
7
0001
8
207
STOP BIT
For setting the number of RS-232C stop bits.
(Unit: bits)
0000
1
0001
2
208
PARITY
For setting whether the RS-232C parity bit is to
be used and, if it is used, whether even or odd
parity is to apply.
0000
NON
The parity bit is not used.
0001
ODD
The parity bit is used with an odd parity.
0002
EVEN
The parity bit is used with an even parity.
No./Item
Description of setting
209
RETURN ACK
For setting whether or not to return the ACK
code when a command is received from RS-
232C.
0000
OFF
The ACK code is not returned
0001
ON
The ACK code is returned.
212
MASTER
PORT
For selecting the remote control connector for
controlling the slave machine when this VTR is
to be used as the master machine for deck-to-
deck operations.
0000
IN/OUT
The IN/OUT connector is used.
0001
OUT
The OUT connector is used.
<Note>
This setting takes effect only when the 9P button
has been set to LOCAL (LED off).