123
Selecting the audio recording channels and
monitor output
Audio recording channels
The audio channels can be selected as shown below using
the AUDIO setup menu items.
Monitor output channels
When
(M MIX) on the <AUDIO SHIFT2> menu is set to
L, R or L/R, the signals of a multiple number of channels can
be mixed and output.
When the number key corresponding to the channel whose
signals are to be monitored is pressed while the “L” (or “R”)
button is held down, that channel is selected, and its signals
are displayed on the audio level meter. (The same steps can
also be taken to de-select a channel which has already been
selected.) However, only up to 2 channels among the CH1-
CH4 channels and only up to 2 channels among the CH5-
CH8 channels are selected.
(Examples: CH1 + CH3 + CH5 + CH8 can be selected but
CH1 + CH2 + CH4 cannot be selected.)
Display saving function
This function is provided to extend the service life of the LCD
monitor. It starts up if none of the front panel controls have
been operated or the cassette tape has not been run at all
for about 5 minutes.
While the saving function is working, the LCD monitor
display goes blank, and the “EX” symbol appears on the time
code display area. [The setting for displaying or not
displaying the logo can be selected in Setup Menu No. 146
(SAVER DISP).]
To release the saving function, operate a button or dial on
the front panel or issue a tape transport command from the
controller. The operation performed to release the function
will be executed after the function is released.
Recording
track
Signals recorded
CH1
CH1/CH2/CH3/CH4/
CH1+CH2/CH3+CH4
CH2
CH1/CH2/CH3/CH4/
CH1+CH2/CH3+CH4
CH3
CH1/CH2/CH3/CH4/
CH1+CH2/CH3+CH4
CH4
CH1/CH2/CH3/CH4/
CH1+CH2/CH3+CH4
CH5
CH5/CH6/CH7/CH8/
CH5+CH6/CH7+CH8
CH6
CH5/CH6/CH7/CH8/
CH5+CH6/CH7+CH8
CH7
CH5/CH6/CH7/CH8/
CH5+CH6/CH7+CH8
CH8
CH5/CH6/CH7/CH8/
CH5+CH6/CH7+CH8
CUE
CUE/CH1/CH2/CH3/CH4/CH5/CH6/CH7/CH8/
CH1+CH2/CH3+CH4/CH5+CH6/CH7+CH8 /
CH1 - CH8
F6
MONITOR SELECT switches
Number keys