367
DP-8032/8025
2008
Ver. 1.2
11.3.3.6. Paddle Solenoid Control
1. Paddle Solenoid switches the drive of the feed motor to the Paddle, which is a Flapper typed Solenoid
and is operated by +24V DC. The control circuit is shown below.
2. Solenoid is turned ON and drives the Paddle when the signal H is transmitted from PG0 of IC2 in
P.C.B. (PBA-CONT).
11.3.3.7. Paper Detection Solenoid Control
1. A +24V DC plunger solenoid along with a paper detection lever is used for detecting the height of the
paper delivered to the Stack Tray. Its control circuit is shown below.
2. It is controlled by the signal from P26 of IC2 in P.C.B. (PBA-CONT). When the P26 is H, the Solenoid is
turned on to pull the paper detection lever inside. When the P25 is H, the Solenoid is turned off to push
the paper detection lever outside.