61
DP-8032/8025
2008
Ver. 1.2
(10) Disconnect the 3
Harnesses
on the Terminals of
Fuser Unit.
Note:
When reinstalling, make sure that the 3 Harnesses
are connected correctly as illustrated.
(11) Disconnect 2
Harnesses
.
(12) Remove 4
Screws
(4N).
(13) Remove the
Fuser Unit
.
(14) Remove 4
Screws
(6P).
(15) Remove the
Dual-Path Exit Guide
.
(16) Clean the
Feed Roller
(1510) with a soft cloth,
saturated with isopropyl alcohol.