045 Ring Detect
Count
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in
1 ring step intervals.
046 On-Hook Time
0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
047 Response Wait
Interval
1 = 1 sec.
~
90 = 90 sec.
20 ~ 150 sec.
(For France Only)
Selects the waiting interval for the response after
completing the dialing.
048
~
049
Not Used
050 Ring Detect
Mode
1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to
“Rough”
so that
the unit may detect the ringing signals.
051 Not Used
052 Pulse Rate
1 = 10 pps
2 = 20 pps
Selects the dial pulse rate 10/20 pps.
053
~
054
Not Used
055 Busy Tone
Check
1 = Off
2 = On
Selects whether to detect the Busy Tone.
056 Dial Tone Check 1 = Off
2 = On
Selects whether to detect Dial Tone before dialing
the telephone number.
057 DC Loop Check
(Except for USA
and Canada)
1 = Off
2 = On
Selects whether the unit checks the DC Loop during
communication.
058 Comm. JRNL +
Image
1 = Off (without image)
2 = On (with image)
Selects whether the machine prints the COMM.
Journal with image.
059 Confidential
RCV Report
1 = Off (does not print out)
2 = On (prints out)
Selects whether the machine prints the Confidential
RCV Report.
060 Version
Indicates the Host software
version.
061 TX/RX/PRT/
CPY
1 = Fax Transmit Count
2 = Fax Receive Count
3 = Total Count
4 = Copy Print Count
Displays the transmitted, received, total printed and
copied document count.
062 Print Counter
1 = Off
2 = On
Selects whether to print in the Fax Parameter List,
the counter information that is displayed in the
Function Parameter No. 61.
063
~
067
Not Used
Function Parameter Table