Section 300-Installation
Chapter 5. Peripheral Equipment
DBS-2.3/9.2-300
DBS Manual - Revised April 2000
5-11
Installation
The following procedures describe direct OPX connection and OPX
connection through a CO. Order an OL13C circuit for an OPX through a CO.
Refer to Figure 5-6 on page 5-13 when installing the OPX.
Installing an OPX Station Without Going Through a Central Office
1. Remove the cover from the OPX Adaptor.
2. Remove the cable punch-out plate (Figure 5-12) to make an opening for
the cables coming into the OPX Adaptor.
To remove the plate, cut the grooves on either side with diagonal shears.
Then bend the plate back and forth with needle-nose pliers to remove it.
Figure 5-5. Cable punch-out plate, OPX Adaptor
3. Mount the OPX Adaptor to the wall.
Note:
Table 5-5 shows how far the Adaptor can be located from the DBS.
Table 5-5. Maximum distances for OPX Adaptor installation
Wiring gauge
Max. distance (in feet) between the DBS and
OPX Adaptor
AWG 22
309
AWG 24
194
AWG 26
122
Summary of Contents for DBS 40
Page 12: ...About This Manual Section 300 Installation xii DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 20: ...2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 30: ...3 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 50: ...4 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 94: ......
Page 96: ...5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 132: ...6 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 144: ...7 2 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...
Page 204: ...Index Section 300 Installation Index 8 DBS Manual Revised April 2000 DBS 2 3 9 2 300 ...