Panasonic CW-XN181AM Series Operating Instructions Manual Download Page 9

-: 6 :-

PREPARATION BEFORE OPERATION

WARNING

Ensure that the power plug
is securely inserted.

A loose plug may cause fire
or an electric shock.

NOTES :

If  the  unit  is  not  going  to  be  used  for  an
extended period of time, remove the power
plug.  Otherwise,  approximately  2.5W  of
electricity will be used even if the unit has
been turned off using the remove control.

HOW TO INSERT BATTERIES

1

2

3

Open the cover.

Insert the two batteries.

Close the cover.

CAUTION

Do not use rechargeable (Ni-Cd) batteries because such batteries differ
from the standard dry cell batteries in shape, dimension and performance.

If operation is stopped, and to be restarted
immediately, the unit will resume operation
only after 3 minutes.

ABOUT THE BATTERIES

The batteries can be used for approximately one year.
Be sure to replace the batteries with two new identical batteries.
Remove the batteries if the air conditioner will not be used for an extended 
period of time

OPERATION CONDITIONS

Use the air conditioner under the
following conditions :
    Operating temperature range.

O

(unit in  C)

Max. Temperature
Min. Temperature

Outdoor side

Indoor side

D.B.T

46

16

D.B.T

35

16

W.B.T

27

11

W.B.T

24

11

NOTE :

 Humidity may exceed 90%

D.B.T. : Dry Bulb Temperature
W.B.T. : Wet Bulb Temperature

Continuous operation at over 90% high
humidity may create condensation and
result in waterdrops on the intake and
outlet vanes.

Summary of Contents for CW-XN181AM Series

Page 1: ...r Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference Englis...

Page 2: ......

Page 3: ...TURES Display Panel 3 Remote Control 3 Operational Instructions 4 5 Preparation Before Operation 6 Air conditioner Installation 7 10 Air conditioner Operation 11 12 Energy Saving Hints 13 Care and Mai...

Page 4: ...se injury Do not try to repair unit yourself Plug in properly before operating and use a specified power cord If abnormal conditions burnt smell etc occur switch off and remove the power plug Confirm...

Page 5: ...oor Side 7 Air Outlet Grille 8 Electronic Control Keypad 9 Power Supply Cord 10 Vertical Vane 2 10 4 9 8 1 3 5 7 6 Precaution for using R32 refrigerant The basic installation work procedures are the s...

Page 6: ...ignal from the remote control 3 User has to refer the photo and feature of same remote shown above which they receive with AC FEATURES Maximum distance 7meters Fan Speed Air Swing Timer On Fan Speed B...

Page 7: ...in Cool Mode only for 5 second in every one minute if Sleep is active CL visible only when operated from Display Panel button dr visible only when operated from Display Panel button Po visible only wh...

Page 8: ...y changing Mode Timer Used to set timer ON when unit is OFF and vice versa Sleep Sleep function can be selected in cool mode only Total 2 degree preset temperature will increment in 8 hour 1 degree in...

Page 9: ...rformance If operation is stopped and to be restarted immediately the unit will resume operation only after 3 minutes ABOUT THE BATTERIES The batteries can be used for approximately one year Be sure t...

Page 10: ...hes towards the back for optimum performance For optimum performance Drain should be plugged For testing purpose and enhanced performance use the Installation guidelines given below INSTALLING THE UNI...

Page 11: ...o the cabinet Lock the chassis to the cabinet with screws LN Series from left 1 nos and right 1 nos side XN Series from back side 2 nos Tilt down for better drainage max 10mm Secure it with wood screw...

Page 12: ...Always use at the rated voltage and with a specific air conditioning circuit This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residen...

Page 13: ...mum cooling efficiency the airconditioner is designed to splash the condensation water on the condenser coil In order to avoid the splashing sound an external drain can be provided by using the follow...

Page 14: ...ose the speed level of the fan The indicator will light up and the beep sound will indicate changing setting NOTE The latest fan speed setting will be memorized and the indicator will light up the nex...

Page 15: ...cancelled manually or due to power failure you can restore the previous setting once power is resumed by pressing Set SET SETTING THE SLEEP MODE SLEEP SLEEP To Maximize comfort while sleeping This op...

Page 16: ...urs the timer setting is cancelled Once power returns reset the timer O Setting the temperature 1 C higher save 10 electricity costs Clean the air filter every 2 weeks Regular cleaning of the air filt...

Page 17: ...wasted NOTE Do not dry the front panel or the air filter in direct sunlight Exposure to direct sunlight may discolour or deform the panel Always turn off the air conditioner and the main power supply...

Page 18: ...is impede by curtains or furniture After 15 minutes of operation it is normal for the temperature difference between intake and outlet air to be more O than 8 C for cooling Humidity is high Condensed...

Page 19: ......

Page 20: ...ACW4PR18901 Refer to operating instruction for handling of End of Life Products...

Reviews: