1. Power supply cord conductors are distinguished according to color.

2. For your safety and protection, this unit is earthed through the power supply cord.

    Please contact the manufacturer or its service dealer or a similarly qualified person if you

    want to replace it.

3. This unit is earthed through the power cord. 

    The wall outlet  should be provided with reliable earth wire.

4. The unit should be provided with an individual circuit and the circuit breaker/fuse rating

    should be the same as that of the power supply cord and wall outlet.

1. Front Grille

2. PM 2.5 Filter

3. Air Filter

4. Remote Control 

5. Cabinet

6. Air Inlet Grille (Outdoor Side)

7. Air Outlet Grille

8. Electronic Control Keypad

9. Power Supply Cord

10. Vertical Vane

2

10

4

9

8

1

3

5

7

6

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

Since the working pressure is higher than that of refrigerant R22 models, some of the piping and 
installation and service tools are special. (Handling of 

R32 is similar to R410A.)

PRECAUTION FOR USING R32 

REFRIGERANT

PARTS IDENTIFICATION

AIR CONDITIONER

 CAUTION

R32

REFRIGERANT

This Air Conditioner contains and 
operates with refrigerant R32.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED 
BY QUALIFIED PERSONNEL.

Refer to National, State, Territory and local legislation, 
regulations, codes, installation & operation manuals, before 
the installation, maintenance and/or service of this product.

Summary of Contents for CW-XN181AM Series

Page 1: ...r Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference Englis...

Page 2: ......

Page 3: ...TURES Display Panel 3 Remote Control 3 Operational Instructions 4 5 Preparation Before Operation 6 Air conditioner Installation 7 10 Air conditioner Operation 11 12 Energy Saving Hints 13 Care and Mai...

Page 4: ...se injury Do not try to repair unit yourself Plug in properly before operating and use a specified power cord If abnormal conditions burnt smell etc occur switch off and remove the power plug Confirm...

Page 5: ...oor Side 7 Air Outlet Grille 8 Electronic Control Keypad 9 Power Supply Cord 10 Vertical Vane 2 10 4 9 8 1 3 5 7 6 Precaution for using R32 refrigerant The basic installation work procedures are the s...

Page 6: ...ignal from the remote control 3 User has to refer the photo and feature of same remote shown above which they receive with AC FEATURES Maximum distance 7meters Fan Speed Air Swing Timer On Fan Speed B...

Page 7: ...in Cool Mode only for 5 second in every one minute if Sleep is active CL visible only when operated from Display Panel button dr visible only when operated from Display Panel button Po visible only wh...

Page 8: ...y changing Mode Timer Used to set timer ON when unit is OFF and vice versa Sleep Sleep function can be selected in cool mode only Total 2 degree preset temperature will increment in 8 hour 1 degree in...

Page 9: ...rformance If operation is stopped and to be restarted immediately the unit will resume operation only after 3 minutes ABOUT THE BATTERIES The batteries can be used for approximately one year Be sure t...

Page 10: ...hes towards the back for optimum performance For optimum performance Drain should be plugged For testing purpose and enhanced performance use the Installation guidelines given below INSTALLING THE UNI...

Page 11: ...o the cabinet Lock the chassis to the cabinet with screws LN Series from left 1 nos and right 1 nos side XN Series from back side 2 nos Tilt down for better drainage max 10mm Secure it with wood screw...

Page 12: ...Always use at the rated voltage and with a specific air conditioning circuit This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residen...

Page 13: ...mum cooling efficiency the airconditioner is designed to splash the condensation water on the condenser coil In order to avoid the splashing sound an external drain can be provided by using the follow...

Page 14: ...ose the speed level of the fan The indicator will light up and the beep sound will indicate changing setting NOTE The latest fan speed setting will be memorized and the indicator will light up the nex...

Page 15: ...cancelled manually or due to power failure you can restore the previous setting once power is resumed by pressing Set SET SETTING THE SLEEP MODE SLEEP SLEEP To Maximize comfort while sleeping This op...

Page 16: ...urs the timer setting is cancelled Once power returns reset the timer O Setting the temperature 1 C higher save 10 electricity costs Clean the air filter every 2 weeks Regular cleaning of the air filt...

Page 17: ...wasted NOTE Do not dry the front panel or the air filter in direct sunlight Exposure to direct sunlight may discolour or deform the panel Always turn off the air conditioner and the main power supply...

Page 18: ...is impede by curtains or furniture After 15 minutes of operation it is normal for the temperature difference between intake and outlet air to be more O than 8 C for cooling Humidity is high Condensed...

Page 19: ......

Page 20: ...ACW4PR18901 Refer to operating instruction for handling of End of Life Products...

Reviews: