A/C INSTALLATION

Repositioning or transfer of the air conditioner due to renovation or moving requires an 
additional service charge, Please consult your dealer before moving.

Select an installation location that can support the weight of the air 
conditioner and one that will not cause increased operating noise 
and vibration.

Ensure  that  airflow  and  noise  from  the  rear  side  of  the  unit 
(outdoor) when installed do not disturb neighbouring residents.

Obstacles placed in front of the air outlet on the rear side of the unit 
(outdoor), or covers placed over it will cause excessive noise and 
deterioration in performance.

CONDENSED WATER DRAINAGE

NOISE CONSIDERATION

TRANSFERRING

DRAIN WATER

To achieve maximum cooling efficiency, the  airconditioner is 
designed to splash the condensation water on the condenser 
coil. 

In order to avoid the splashing sound, an external drain can be 
provided by using the following procedure. This may however 
cause a small loss of performance.

1.  Slide out the chassis from the cabinet.

2.  Remove the rubber plug from the body base plate.

3.  Install the Drain Pan at corner of the Cabinet with single 

screw.

4.  Connect the drain hose to the outlet on the bottom of the 

drain pan.

5.  Slide the chassis into its original place in the cabinet.

External  View

Drain Hose

Slide out the chassis from the cabinet.
 Remove the rubber plug from the body
base plate.

1

2

3

4

Slide the chassis back into the cabinet.
Lock  the  chassis  to  the  cabinet.  Then
reinstall the cabinet to the chassis.

Install the drain pan at the right corner
of the cabinet using 1 screw.

Internal  View

Screw

Drain Pan

Screw

Drain Pan

Summary of Contents for CW-XN181AM Series

Page 1: ...r Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference Englis...

Page 2: ......

Page 3: ...TURES Display Panel 3 Remote Control 3 Operational Instructions 4 5 Preparation Before Operation 6 Air conditioner Installation 7 10 Air conditioner Operation 11 12 Energy Saving Hints 13 Care and Mai...

Page 4: ...se injury Do not try to repair unit yourself Plug in properly before operating and use a specified power cord If abnormal conditions burnt smell etc occur switch off and remove the power plug Confirm...

Page 5: ...oor Side 7 Air Outlet Grille 8 Electronic Control Keypad 9 Power Supply Cord 10 Vertical Vane 2 10 4 9 8 1 3 5 7 6 Precaution for using R32 refrigerant The basic installation work procedures are the s...

Page 6: ...ignal from the remote control 3 User has to refer the photo and feature of same remote shown above which they receive with AC FEATURES Maximum distance 7meters Fan Speed Air Swing Timer On Fan Speed B...

Page 7: ...in Cool Mode only for 5 second in every one minute if Sleep is active CL visible only when operated from Display Panel button dr visible only when operated from Display Panel button Po visible only wh...

Page 8: ...y changing Mode Timer Used to set timer ON when unit is OFF and vice versa Sleep Sleep function can be selected in cool mode only Total 2 degree preset temperature will increment in 8 hour 1 degree in...

Page 9: ...rformance If operation is stopped and to be restarted immediately the unit will resume operation only after 3 minutes ABOUT THE BATTERIES The batteries can be used for approximately one year Be sure t...

Page 10: ...hes towards the back for optimum performance For optimum performance Drain should be plugged For testing purpose and enhanced performance use the Installation guidelines given below INSTALLING THE UNI...

Page 11: ...o the cabinet Lock the chassis to the cabinet with screws LN Series from left 1 nos and right 1 nos side XN Series from back side 2 nos Tilt down for better drainage max 10mm Secure it with wood screw...

Page 12: ...Always use at the rated voltage and with a specific air conditioning circuit This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residen...

Page 13: ...mum cooling efficiency the airconditioner is designed to splash the condensation water on the condenser coil In order to avoid the splashing sound an external drain can be provided by using the follow...

Page 14: ...ose the speed level of the fan The indicator will light up and the beep sound will indicate changing setting NOTE The latest fan speed setting will be memorized and the indicator will light up the nex...

Page 15: ...cancelled manually or due to power failure you can restore the previous setting once power is resumed by pressing Set SET SETTING THE SLEEP MODE SLEEP SLEEP To Maximize comfort while sleeping This op...

Page 16: ...urs the timer setting is cancelled Once power returns reset the timer O Setting the temperature 1 C higher save 10 electricity costs Clean the air filter every 2 weeks Regular cleaning of the air filt...

Page 17: ...wasted NOTE Do not dry the front panel or the air filter in direct sunlight Exposure to direct sunlight may discolour or deform the panel Always turn off the air conditioner and the main power supply...

Page 18: ...is impede by curtains or furniture After 15 minutes of operation it is normal for the temperature difference between intake and outlet air to be more O than 8 C for cooling Humidity is high Condensed...

Page 19: ......

Page 20: ...ACW4PR18901 Refer to operating instruction for handling of End of Life Products...

Reviews: