Panasonic CW-XN181AM Series Operating Instructions Manual Download Page 14

-: 11 :-

A/C OPERATION

OPERATING THE UNIT

SELECTING OPERATION MODE

SELECTING FAN SPEED

ADJUSTING HORIZONTAL AIRFLOW DIRECTION

Start operation by pressing OFF/ON Button.
The operation will turn on and the display panel will light up.
To stop the operation, press the OFF/ON Button again.
The unit will stop operating and the display panel light will turn off.
Please note that the OFF indication is as follows :
To Start :
To Stop :

Press MODE to select the desired operation.
The indicator will light up and a "beep" sound will indicate
changing setting.

COOL mode

To set room temperature to your preference of cooling comfort.

FAN mode

To provide air circulation without cooling the room.
During Fan operation, temperature setting cannot be selected.

DRY mode

Fan motor Run at only low speed, and cannot be changed. The
comp On/Off duration is controlled by difference between room
temp and set temp.

Press FAN SPEED to choose the speed level of the fan.
The indicator will light up and the "beep" sound will indicate
changing setting.

NOTE:

    The latest fan speed setting  will be memorized and the
    indicator will light up the next time the unit is turned on.

Press to select AIR SWING.
The air circulation will automatically move the
horizontal louvers left and right for better air
distribution around the room.

NOTE:

Using your hands to adjust the direction may
cause the louvers to malfunction. If this
happens, stop operation immediately and restart.

OFF/ON

MODE

MED

HIGH

FAN SPEED

AIR SWING

Vertical

louvers

NOTE :

Vertical
adjustment
of the airflow
direction is
done manually.

SETTING DISPLAY TEMPERATURE

Press TEMP 

or 

to set the display temperature.

O

O

The temperature can be set between 16 C and 30 C

O

O

Recommended temperature: 26 C ~ 28 C
NOTES:

   The latest temperature setting will be memorized and will appear
   on the display the next time it's turned on.
   The Display temperature selection is for display purpose only
   and shows the temperature set by you.

POWER

TEMP/TIME

COOL

FAN

DRY

FAN SPEED

FAN

COOL

DRY

LOW

SWING

TEMP

OFF

OFF

Summary of Contents for CW-XN181AM Series

Page 1: ...r Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference Englis...

Page 2: ......

Page 3: ...TURES Display Panel 3 Remote Control 3 Operational Instructions 4 5 Preparation Before Operation 6 Air conditioner Installation 7 10 Air conditioner Operation 11 12 Energy Saving Hints 13 Care and Mai...

Page 4: ...se injury Do not try to repair unit yourself Plug in properly before operating and use a specified power cord If abnormal conditions burnt smell etc occur switch off and remove the power plug Confirm...

Page 5: ...oor Side 7 Air Outlet Grille 8 Electronic Control Keypad 9 Power Supply Cord 10 Vertical Vane 2 10 4 9 8 1 3 5 7 6 Precaution for using R32 refrigerant The basic installation work procedures are the s...

Page 6: ...ignal from the remote control 3 User has to refer the photo and feature of same remote shown above which they receive with AC FEATURES Maximum distance 7meters Fan Speed Air Swing Timer On Fan Speed B...

Page 7: ...in Cool Mode only for 5 second in every one minute if Sleep is active CL visible only when operated from Display Panel button dr visible only when operated from Display Panel button Po visible only wh...

Page 8: ...y changing Mode Timer Used to set timer ON when unit is OFF and vice versa Sleep Sleep function can be selected in cool mode only Total 2 degree preset temperature will increment in 8 hour 1 degree in...

Page 9: ...rformance If operation is stopped and to be restarted immediately the unit will resume operation only after 3 minutes ABOUT THE BATTERIES The batteries can be used for approximately one year Be sure t...

Page 10: ...hes towards the back for optimum performance For optimum performance Drain should be plugged For testing purpose and enhanced performance use the Installation guidelines given below INSTALLING THE UNI...

Page 11: ...o the cabinet Lock the chassis to the cabinet with screws LN Series from left 1 nos and right 1 nos side XN Series from back side 2 nos Tilt down for better drainage max 10mm Secure it with wood screw...

Page 12: ...Always use at the rated voltage and with a specific air conditioning circuit This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residen...

Page 13: ...mum cooling efficiency the airconditioner is designed to splash the condensation water on the condenser coil In order to avoid the splashing sound an external drain can be provided by using the follow...

Page 14: ...ose the speed level of the fan The indicator will light up and the beep sound will indicate changing setting NOTE The latest fan speed setting will be memorized and the indicator will light up the nex...

Page 15: ...cancelled manually or due to power failure you can restore the previous setting once power is resumed by pressing Set SET SETTING THE SLEEP MODE SLEEP SLEEP To Maximize comfort while sleeping This op...

Page 16: ...urs the timer setting is cancelled Once power returns reset the timer O Setting the temperature 1 C higher save 10 electricity costs Clean the air filter every 2 weeks Regular cleaning of the air filt...

Page 17: ...wasted NOTE Do not dry the front panel or the air filter in direct sunlight Exposure to direct sunlight may discolour or deform the panel Always turn off the air conditioner and the main power supply...

Page 18: ...is impede by curtains or furniture After 15 minutes of operation it is normal for the temperature difference between intake and outlet air to be more O than 8 C for cooling Humidity is high Condensed...

Page 19: ......

Page 20: ...ACW4PR18901 Refer to operating instruction for handling of End of Life Products...

Reviews: