10.5. Outdoor unit installation
• Precautions shown here are differentiated between
Warnings and
Cautions. Those that have much chances for leading to
significant result such as fatality or serious injury if wrong installation would have been carried out are listed compiling them
especially into the column of
Warnings.
However, even in the case of items which are listed in the column of
Cautions, such items also have a chance for leading to
significant result depending on the situations.
In either case, important descriptions regarding the safety are listed, then observe them without fail.
• As to indications with illustration
• After installation work has been completed, do not only make sure that the unit is free from any abnormal condition through the
execution of try run but also explain how to use and how to perform maintenance of this unit to the customer according to the
instruction manual.
In addition, request the customer to keep this manual for installation work together with instruction manual.
AIR CONDITIONERS OUTDOOR UNIT INSTALLATION INSTRUCTIONS
Precautions in terms of safety
Carry out installation work with reliability after thorough reading of this “Precautions in terms of safety”.
This mark means “Caution” or “Warning”.
This mark means “Earth”.
Warnings
The appliance must be installed by technician, who takes into
account the requirements given by ISO5149 or eventual equiva-
lent requirements.
Wiring shall be connected securely using specified cables and fix
them securely so that external force of the cables may not transfer
to the terminal connection section.
Imperfect connection and fixing leads to fire, etc.
As to installation, request the distributor or vendor to perform it.
Imperfection in installation caused by that having been carried out
by the customer himself may lead to water leakage, electric
shock, fire, etc.
If installing inside a small room, measures should be taken to pre-
vent refrigerant levels from building up to critical concentrations in
the event of a refrigerant leak occurring. Please discuss with the
place of purchase for advice on what measures may be necessary
to prevent critical concentrations being exceeded. If the refrigerant
leaks and reaches critical concentration levels, there is the danger
that death from suffocation may result.
Carry out the installation work with reliability according to this
manual for installation work.
Imperfection in installation leads to water leakage, electric shock,
fire, etc.
Securely attach the protective covers for the outdoor unit connec-
tion cables and power cord so that they do not lift up after installa-
tion. If the covers are not properly attached and installed, the
terminal connections may overheat, and fire or electric shock may
result.
Carry out the installation work with reliability on the place that can
bear the weight of this unit sufficiently. Insufficient strength leads
to injury due to falling of the unit.
Switch off all supplies before accessing any electrical part.
Carry out predetermined installation work in preparation for strong
wind such as typhoon, earthquake.
Imperfection in installation work may lead to accidents arisen from
overturn, etc.
If refrigerant gas escapes during installation, ventilate the affected
area. If the refrigerant gas comes into contact with sparks or naked
flames, it will cause toxic gases to be generated.
Summary of Contents for CU-B14DBE5
Page 11: ...11 4 Dimensions 4 1 CS F18DTE5 ...
Page 12: ...12 4 2 CU J18DBE5 ...
Page 13: ...13 5 Refrigeration Cycle 5 1 CS F18DTE5 CU J18DBE5 ...
Page 14: ...14 6 Block Diagram 6 1 CS F18DTE5 6 2 CU J18DBE5 ...
Page 15: ...15 7 Wiring Diagram 7 1 CS F18DTE5 ...
Page 16: ...16 7 2 CU J18DBE5 ...
Page 18: ...18 8 2 Remote Control Display ...
Page 19: ...19 8 3 Remote Control Panel ...
Page 95: ...95 13 3 Reaching distance CS F18DTE5 Cooling ...
Page 96: ...96 13 4 Sound data ...
Page 97: ...97 13 5 Sound measuring point 13 5 1 Indoor Unit 13 5 2 Outdoor Unit ...
Page 100: ...100 14 Exploded View Indoor Unit 14 1 CS F18DTE5 ...
Page 101: ...101 14 2 CS F18DTE5 ...
Page 102: ...102 14 3 CS F18DTE5 ...
Page 105: ...105 16 Exploded View Outdoor Unit 16 1 CU J18DBE5 ...
Page 106: ...106 16 2 CU J18DBE5 ...
Page 108: ...108 18 Print Pattern 18 1 Indoor Unit Printed Main ...