12.2 Indoor Unit
12.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
Model
Dimension
1 2
3
4
5
6
Z20***, Z25***, Z35***, Z42***,
XZ20***, XZ25***, XZ35***
500 mm
70 mm ( * )
420 mm
450 mm
113 mm
165 mm
Model
Dimension
1 2
3
4
5
6
Z50***, Z71***,
XZ50***
587 mm
70 mm ( * )
537 mm
503 mm
226 mm
278 mm
The center of installation plate should be at more than
1
at right and left of the wall.
The distance from installation plate edge to ceiling should more than
2
.
From installation plate center to unit’s left side is
3
.
From installation plate center to unit’s right side is
4
.
○
B : For left side piping, piping connection for liquid should be about
5
from this line.
: For left side piping, piping connection for gas should be about
6
from this line.
Dimension
2
(*) :-
If holder at the rear of chassis
(Refer column “12.2.3 Indoor
Unit Installation”) need to be
used to prop up the unit, this
distance shall be 85 mm or
more.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
o
Line according to the left and right side of the installation plate. The meeting point of the extended line is
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 150 mm for left and right hole
respectively ( Z20***, XZ20***, Z25***, XZ25***, Z35***, XZ35***, Z42***) or 210 mm for left hole and
150 mm for right hole ( Z50***, XZ50***, Z71*** ).
o
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side.
PIPE HOLE
CENTER
150 mm
TO HOLE
CENTER
PIPE HOLE
CENTER
150 mm
TO HOLE
CENTER
Ceiling
Wall
Wall
Installation
plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
216 mm
150 mm
150 mm
247 mm
150 mm
More than
2
For best strength of INDOOR
unit installation, it is highly
recommended to locate “ ”
at 5 position as shown.
3
6
5
4
PIPE HOLE
CENTER
210 mm
TO HOLE
CENTER
PIPE HOLE
CENTER
150 mm
TO HOLE
CENTER
Ceiling
Wall
Wall
Installation
plate
1
2
screw
More than
1
More than
1
Measuring Tape
Indoor unit
276 mm
150 mm
210 mm
247 mm
150 mm
More than
2
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
210 mm
3
6
5
4