177
21.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
-
Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
-
Unit setting: Standard piping length, forced heating at 30°C, Hi fan
-
Compressor frequency: Rated for Heating operation
-
Piping length: 5m
-
Voltage: 230V
21.2.1 CS-Z20XKEW
CU-Z20XKE
CS-XZ20XKEW CU-Z20XKE
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
High Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
0.50
1.00
1.50
2.00
2.50
3.00
15
20
25
30
35
40
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
1.00
1.50
2.00
2.50
3.00
3.50
4.00