hr
DELAY
hr
DELAY
OFF
ON
ON
OFF
AUTO
HEAT
COOL
DRY
OFF
47
Removal Procedure For Cross Flow Fan
1.
(Fig. 12)
Release the two fixing screws,disassembly the fixing board from
evaporator on the left side of the evaporator and pull out the whole
evaporator.
2.Loose the fixing screw of the cross flow fan. (Fig. 13)
Fig. 12
Fig. 13
Fixing Screw
3.After removing the bearing (refer to fig14) , indoor fan can be
taken out from the left side.
Bearing
4. Lift up the indoor fan slightly, and then pull the fan motor out.
Fig15
Fig 15
Fan motor
Fig 14
fixing board
Screw
Remote control reset
If the display is chaotic or can not be adjusted,
Use a pin to press RESET button to reset the remote control to
the original set by manufacture.
Fig 16
CANCEL
SELECT
CS-XA9DKD / CU-
/ CS-
/ CU-
XA9DKD
XA12DKD
XA12DKD
Fig 15
Fig 16