9.2.5.
CONNECT THE CABLE TO THE
INDOOR UNIT
1. The inside and outside connecting cable can be connected
without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall
be
approved
polychloroprene
sheathed
6 x 1.5 mm
2
flexible cord, type designation 245
IEC 57 or heavier cord. The attached wire 6 with two
connectors should be applied.
Ensure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor's respectively.
Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
Secure the cable onto the control board with the holder
(clamper).
- 32 -
Apply putty or caulking material to seal the wall opening
PVC tube for drain hose
Cable
Piping
Indoor
Unit
5.5 cm
Connecting cable
Piping
Drain hose from main unit
PVC tube for drain hose (VP-30)
PVC tube for
drain hose (VP-20)
More
than
70
cm
More
than
95
cm
More
than
30 cm
PVC tube (VP-65) for piping and connecting cable
How to pull the piping and drain hose out, in case of the embedded piping.
Oxygen
tube
Oxygen tube
(For the right piping, follow the same procedure)
Cable
Drain hose
Piping
45
¼
In case of left piping how to insert the connecting cable
and drain hose
.
Oxygen tube
Terminals on the indoor unit
3
4
5
C olor of wires
Terminals on the outdoor unit
3
4
5
1(L)
2(N)
1(L)
2(N)
Connector
1(L) 2(N) 3 4 5
CS-XA9DKD/ CU-XA9DKD/ CS-XA12DKD/ CU-XA12DKD