8.4.
Automatic Mode Operation
CS-XA9DKD / CU-XA9DKD / CS-XA12DKD / CU-XA12DKD
Standard for Determining Operation Mode
Cooling mode
Soft Dry mode
Heating mode
Cooling mode
Soft Dry mode
Heating mode
Intake Air
temperature
Setting Temperature (Standard)
23
℃
20
℃
25
℃
22
℃
21
℃
One hour after the above determination, the unit will operate according to the table below.
First
determination
Cooling
Dry
Heating
Second Determination
Cooling
Dry
Heating
23
or above
℃
25
or above
℃
20
or above
℃
23
below
℃
20
below
℃
25
below
℃
Second Determination:
First Determination:
Indoor fan operates at super low speed for 20 seconds.
After judging indoor air temperature, the operation is determined and operation continued at the mode determined.
If indoor temperature is less than 16
, heating operation will immediately operate.
After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation
includes cooling mode operation.
If automatic mode operation is started while the unit is operating, operation will continue.
If current operation is in cooling mode (including the cooling mode operation when is a part of Soft Dry mode
operation) it will be maintained, and if current operation is not cooling mode, the appropriate operation mode is
determined for 20seconds at super slow fan speed. Then the selected mode will continue.
The setting temperature for all the operations can be changed one level up or one level down from the standard
temperature as shown below by pressing the temperature up or down button at remote control.
℃
A)
B)
C)
D)
E)
F)
Higher
Standard
Lower
2
℃
0
℃
2
℃
27
℃
24
℃
Cooling
Soft Dry
25
℃
22
℃
23
℃
20
℃
23
℃
Heating
21
℃
19
℃
8.5.
Indoor Fan Motor Control
Automatic fan speed control
When automatic fan speed set, the available range for fan speed is from Hi to Sslo.
Manual Fan Speed Control
Basic fan speed can be manually adjusted (Lo, Med, Hi) by using the fan speed selection button.