background image

7

2-4. Presence of 

fi

re extinguisher

• If any hot work is to be conducted on the 

refrigeration equipment or any associated 

parts, appropriate fire extinguishing 

equipment shall be available at hand.

• Have a dry powder or CO

2

fire extinguisher 

adjacent to the charging area.

2-5. No ignition sources

• No person carrying out work in relation to a 

refrigeration system which involves exposing 

any pipe work that contains or has contained 

flammable refrigerant shall use any sources 

of ignition in such a manner that it may lead 

to the risk of fire or explosion. He/She must 

not be smoking when carrying out such work.

• All possible ignition sources, including 

cigarette smoking, should be kept sufficiently 

far away from the site of installation, 

repairing, removing and disposal, during 

which flammable refrigerant can possibly be 

released to the surrounding space.

• Prior to work taking place, the area around 

the equipment is to be surveyed to make 

sure that there are no flammable hazards or 

ignition risks.

• “No Smoking” signs shall be displayed.

2-6. Ventilated area

• Ensure that the area is in the open or that it 

is adequately ventilated before breaking into 

the system or conducting any hot work.

• A degree of ventilation shall continue during 

the period that the work is carried out.

• The ventilation should safely disperse any 

released refrigerant and preferably expel it 

externally into the atmosphere.

2-7. Checks to the refrigeration equipment

• Where electrical components are being 

changed, they shall be fit for the purpose 

and to the correct specification.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• The following checks shall be applied to 

installations using flammable refrigerants.

- The charge size is in accordance with 

the room size within which the refrigerant 

containing parts are installed.

- The ventilation machinery and outlets are 

operating adequately and are not obstructed.

- If an indirect refrigerating circuit is being 

used, the secondary circuit shall be 

checked for the presence of refrigerant.

- Marking to the equipment continues to be 

visible and legible. Markings and signs that 

are illegible shall be corrected.

- Refrigeration pipe or components are 

installed in a position where they are unlikely 

to be exposed to any substance which may 

corrode refrigerant containing components, 

unless the components are constructed of 

materials which are inherently resistant to 

being corroded or are properly protected 

against being so corroded.

2-8. Checks to electrical devices

• Repair and maintenance to electrical 

components shall include initial safety 

checks and component inspection 

procedures.

• Initial safety checks shall include but not 

limit to:-

- That capacitors are discharged: this 

shall be done in a safe manner to avoid 

possibility of sparking.

- That there no live electrical components 

and wiring are exposed while charging, 

recovering or purging the system.

- That there is continuity of earth bonding.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• If a fault exists that could compromise safety, 

then no electrical supply shall be connected 

to the circuit until it is satisfactorily dealt with.

• If the fault cannot be corrected immediately 

but it is necessary to continue operation, an 

adequate temporary solution shall be used.

• The owner of the equipment must be 

informed or reported so all parties are 

advised thereinafter.

3. Repairs to sealed components

• During repairs to sealed components, all 

electrical supplies shall be disconnected 

from the equipment being worked upon prior 

to any removal of sealed covers, etc.

• If it is absolutely necessary to have an 

electrical supply to equipment during 

servicing, then a permanently operating 

form of leak detection shall be located at the 

most critical point to warn of a potentially 

hazardous situation.

• Particular attention shall be paid to the 

following to ensure that by working on 

electrical components, the casing is not 

altered in such a way that the level of 

protection is affected.

This shall include damage to cables, 

excessive number of connections, terminals 

not made to original specification, damage to 

seals, incorrect fitting of glands, etc.

• Ensure that apparatus is mounted securely.

• Ensure that seals or sealing materials have 

not degraded such that they no longer serve 

the purpose of preventing the ingress of 

flammable atmospheres.

• Replacement parts shall be in accordance 

with the manufacturer’s specifications.

NOTE: The use of silicon sealant may inhibit 

the effectiveness of some types of leak 

detection equipment.

Intrinsically safe components do not have to 

be isolated prior to working on them.

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2705̲OL.ai   7   3/3/2020   9:56:29 AM

ACXF55-2705̲OL.ai   7   3/3/2020   9:56:29 AM

Summary of Contents for CS-WU12WKY Series

Page 1: ...WKYF series CU XU24WKYF series ACXF55 27050 AD English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C M Y CM MY CY CMY K ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ...

Page 3: ...1 C 2 C lower than room temperature Use remote control around 7 m from the remote control receiver of the indoor unit FAN DRY JET STREAM FAN SPEED MODE TEMP AIR SWING SLEEP DISPLAY CLEAN ON OFF CANCEL nanoe G LOCK RESET RC AC CHECK SET SMART 2 1 3 Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 Ag Clean PM 2 5 Filter 7m C M Y CM ...

Page 4: ...ware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or ...

Page 5: ...odels Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outd...

Page 6: ... their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performe...

Page 7: ...tance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include b...

Page 8: ...tion When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refri...

Page 9: ...frigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant reco...

Page 10: ...power consumption during COOL mode use curtains to screen off sunlight and outdoor heat Unit operates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides fresh air ci...

Page 11: ...e DBT Dry bulb temperature WBT Wet bulb temperature 52 30 Can be activated even when the unit is turned off In this condition the unit will operate as a fan with AUTO fan speed and louver swing nanoe G Purifier nanoe G For faster cooling and a longer air throw JETSTREAM Display on remote LCD This operation stops automatically after 1 hours JET STREAM QUIET To enjoy quiet operation This operation r...

Page 12: ...n to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nan...

Page 13: ...t s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 C M Y CM MY CY CMY K ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ...

Page 14: ... CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON button on Indoor Unit All this should be done within 5 seconds Auto OFF ON Butt...

Page 15: ...nasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Refer ...

Page 16: ... source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2705 OL ai 16...

Reviews: