background image

4

Safety precautions

To prevent personal injury, injury to others or property 
damage, please comply with the following: 
Incorrect operation due to failure to follow instructions 
below may cause harm or damage, the seriousness of 
which is classified as below:

This appliance is filled with R32 (mild 
flammable refrigerant). If the refrigerant is 
leaked and exposed to an external ignition 
source, there is a risk of fire.

WARNING

This sign warns of death 
or serious injury.

CAUTION

This sign warns of injury 
or damage to property.

The instructions to be followed are classified by the 
following symbols:

This symbol denotes an action that 
is PROHIBITED.

These symbols denote actions 

COMPULSORY.

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have 
been given supervision or instruction concerning 
use of the appliance by a person responsible for 
their safety. Children should be supervised to 
ensure that they do not play with the appliance.
The appliance shall be installed, and/or operated 
in a room with floor area larger than A

min

(m²) and 

keep away from ignition sources, such as heat/
sparks/open flame or hazardous areas such as 
gas appliances, gas cooking, reticulated gas 
supply systems or electric cooking appliances, etc.
(Refer to Table A of Installation instructions table 
for A

min

(m²))

Be aware that refrigerant may not contain an 
odour, highly recommended to ensure suitable 
flammable refrigerant gas detectors are present, 
operating and able to warn of a leak.
Please consult authorised dealer or specialist to 
clean the internal parts, repair, install, remove 
and reinstall the unit. Improper installation and 
handing will cause leakage, electric shock or fire.
Confirm with authorised dealer or specialist on 
usage of any specified refrigerant type. 
Using refrigerant type other than the specified 
may cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting 
process or to clean, other than those 
recommended by manufacturer. Any unfit 
method or using incompatible material may 
cause product damage, burst and serious injury.
Do not pierce or burn as the appliance is 
pressurized. Do not expose the appliance to 
heat, flame, sparks, or other sources of ignition. 
Else it may explode and cause injury or death.
Do not install the unit in a potentially explosive 
or flammable atmosphere. Failure to do so could 
result in fire.
Do not insert your fingers or other objects 
into the air conditioner indoor or outdoor 
unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it 
may cause electric shock.
Do not expose yourself directly to cold air for a 
long period to avoid excess cooling.
Do not sit or step on the unit, you may 
fall down accidentally.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air inlet

Air inlet

Air outlet

Air outlet

Air outlet

Air outlet

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2705̲OL.ai   4   3/3/2020   9:56:28 AM

ACXF55-2705̲OL.ai   4   3/3/2020   9:56:28 AM

Summary of Contents for CS-WU12WKY Series

Page 1: ...WKYF series CU XU24WKYF series ACXF55 27050 AD English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C M Y CM MY CY CMY K ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ...

Page 3: ...1 C 2 C lower than room temperature Use remote control around 7 m from the remote control receiver of the indoor unit FAN DRY JET STREAM FAN SPEED MODE TEMP AIR SWING SLEEP DISPLAY CLEAN ON OFF CANCEL nanoe G LOCK RESET RC AC CHECK SET SMART 2 1 3 Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 Ag Clean PM 2 5 Filter 7m C M Y CM ...

Page 4: ...ware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or ...

Page 5: ...odels Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outd...

Page 6: ... their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performe...

Page 7: ...tance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include b...

Page 8: ...tion When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refri...

Page 9: ...frigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant reco...

Page 10: ...power consumption during COOL mode use curtains to screen off sunlight and outdoor heat Unit operates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides fresh air ci...

Page 11: ...e DBT Dry bulb temperature WBT Wet bulb temperature 52 30 Can be activated even when the unit is turned off In this condition the unit will operate as a fan with AUTO fan speed and louver swing nanoe G Purifier nanoe G For faster cooling and a longer air throw JETSTREAM Display on remote LCD This operation stops automatically after 1 hours JET STREAM QUIET To enjoy quiet operation This operation r...

Page 12: ...n to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nan...

Page 13: ...t s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 C M Y CM MY CY CMY K ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ...

Page 14: ... CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON button on Indoor Unit All this should be done within 5 seconds Auto OFF ON Butt...

Page 15: ...nasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Refer ...

Page 16: ... source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2705 OL ai 16...