background image

English

11

How to use

To adjust airflow direction

(Remote control display)

• Keeps the room ventilated.
• If AUTO air swing is set, the flaps swings 
  left/right and up/down automatically.
• The horizontal and vertical flap are fixed at the
  predetermined position.
• Do not adjust the flap by hand.

(Vertical)

(Horizontal)

To set the timer

To turn ON and OFF the unit at a preset times. 

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 
of time with previous operation mode and airflow 
direction.

• This control is not applicable when SLEEP, CLEAN,
  TIMER is set.
• In TIMER set conditions if there is power reset then
  unit will start in stand by mode.

To select fan speed 

(Remote control display)

(Low)

(Medium)

(High)

AUTO

FAN

QUIET

• For AUTO, the indoor fan speed is automatically
  adjusted according to the operation mode. 

Operation conditions

Use this air conditioner under the following
temperature range.
DBT  : Dry bulb temperature
WBT : Wet bulb temperature

52

30

• Can be activated even when the unit is turned
  off. In this condition, the unit will operate as a fan
  with AUTO fan speed and louver swing.

nanoe-G Purifier

nanoe-G

For faster cooling and a longer 
air throw 

JETSTREAM: Display on remote LCD

• This operation stops automatically after 1 hours.

JET

STREAM

QUIET: To enjoy quiet operation

• This operation reduces airflow noise.

ON

OFF

CANCEL

1

2

• To cancel ON or OFF timer, press        . 
• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing         or        then wait for “5” sec. 

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to “15” minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

ON

OFF

CANCEL

Select ON or OFF
timer

Set the time

Confirm

Example:
OFF at 14:00  

Press the OFF 
button.  

OFF

OFF

OFF

OFF

OFF

OFF

Wait for “5” second to set timer.  

Press OFF button again to
increase timer time in step
of “10” minutes.  

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2705̲OL.ai   11   3/3/2020   9:56:31 AM

ACXF55-2705̲OL.ai   11   3/3/2020   9:56:31 AM

Summary of Contents for CS-WU12WKY Series

Page 1: ...WKYF series CU XU24WKYF series ACXF55 27050 AD English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C M Y CM MY CY CMY K ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ...

Page 3: ...1 C 2 C lower than room temperature Use remote control around 7 m from the remote control receiver of the indoor unit FAN DRY JET STREAM FAN SPEED MODE TEMP AIR SWING SLEEP DISPLAY CLEAN ON OFF CANCEL nanoe G LOCK RESET RC AC CHECK SET SMART 2 1 3 Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 Ag Clean PM 2 5 Filter 7m C M Y CM ...

Page 4: ...ware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or ...

Page 5: ...odels Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outd...

Page 6: ... their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performe...

Page 7: ...tance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include b...

Page 8: ...tion When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refri...

Page 9: ...frigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant reco...

Page 10: ...power consumption during COOL mode use curtains to screen off sunlight and outdoor heat Unit operates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides fresh air ci...

Page 11: ...e DBT Dry bulb temperature WBT Wet bulb temperature 52 30 Can be activated even when the unit is turned off In this condition the unit will operate as a fan with AUTO fan speed and louver swing nanoe G Purifier nanoe G For faster cooling and a longer air throw JETSTREAM Display on remote LCD This operation stops automatically after 1 hours JET STREAM QUIET To enjoy quiet operation This operation r...

Page 12: ...n to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nan...

Page 13: ...t s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 C M Y CM MY CY CMY K ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ...

Page 14: ... CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON button on Indoor Unit All this should be done within 5 seconds Auto OFF ON Butt...

Page 15: ...nasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Refer ...

Page 16: ... source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2705 OL ai 16...

Reviews: