background image

JET

STREAM

FAN SPEED

MODE

TEMP

AIR SWING

SLEEP

DISPLAY

CLEAN

ON

OFF

CANCEL

nanoe-G

LOCK

RESET

RC

AC

CHECK

SET

SMART

How to use

Auto OFF/ON button

Use when remote control is misplaced or a malfunction occurs. Raise the front panel:
• To use in AUTO mode, press the button once.  
• To use in COOL mode, press and hold the button until 1 beep is heard, then 

release. 

• Press the button again to turn off.

Press to restore the 
remote control to 
default setting.

Press this button to 
switch OFF/ON
hidden display.

Not used in normal 
operations.

Press for 5 seconds to 

lock remote

Remote control 
display

Remote control

receiver and indicator 

nanoe-G
Wi-Fi

TIMER

10

To maximise comfort while 

sleeping

• This operation provides you with a comfortable
  environment while sleeping by gradually increase
  the set temperature 1 °C after every 3 hours operation.
• The unit is turned off after 8 hours.
• Can be cancelled by pressing the respective
  button again. 

SLEEP

To select operation mode

AUTO - For your convenience 

COOL - To enjoy cool air 

DRY - To dehumidify the environment

Unit run with optimised settings.
You can change the temperature according to 
your comfort. 

To reduce power consumption during COOL mode, 
use curtains to screen off sunlight and outdoor heat.

Unit operates at low fan speed to give a gentle
cooling operation.

FAN - To operate Air-Con in “Fan Only” mode

* Indoor unit temp. display will show set temp. for 

  AUTO,COOL & DRY mode and room temp. for FAN 

  mode.

Only indoor unit fan operates as per remote settings.
Outdoor is OFF, so no cooling achieved.
Provides fresh air circulation in the room.

To OFF/ON hidden temperature
display

• When the display is turn OFF by remote controller,
  It will turn ON automatically for few seconds upon
  receiving any command from remote or in case of
  mains power reset. 

DISPLAY

To clean dust on evap. coil of
the Air-Conditioner Unit

CLEAN

• 

‘CL’ will be displayed on unit and remote controller.

   While ‘CL’ is diplayed, all other functions of the
   remote controller will be disabled, except for
   ON/OFF button. Applicable for 10 to 15 minutes.

•  This feature can only be used in OFF condition.

To turn ON/OFF Wi-Fi function 
of Air-Conditioner Unit.

Wi-Fi

SMART

Use            button for one time to switch ON Wi-Fi.
Press            button for “5” seconds to enter in 
setup mode.

Press            followed by CANCEL button to turn 
OFF Wi-Fi for “4” hours.
Press CANCEL button for “10” seconds to check
Wi-Fi connection.  

SMART

SMART

SMART

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2705̲OL.ai   10   3/3/2020   9:56:29 AM

ACXF55-2705̲OL.ai   10   3/3/2020   9:56:29 AM

Summary of Contents for CS-WU12WKY Series

Page 1: ...WKYF series CU XU24WKYF series ACXF55 27050 AD English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C M Y CM MY CY CMY K ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ACXF55 2705 OL ai 1 3 3 2020 9 56 19 AM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ACXF55 2705 OL ai 2 3 3 2020 9 56 26 AM ...

Page 3: ...1 C 2 C lower than room temperature Use remote control around 7 m from the remote control receiver of the indoor unit FAN DRY JET STREAM FAN SPEED MODE TEMP AIR SWING SLEEP DISPLAY CLEAN ON OFF CANCEL nanoe G LOCK RESET RC AC CHECK SET SMART 2 1 3 Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 Ag Clean PM 2 5 Filter 7m C M Y CM ...

Page 4: ...ware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or ...

Page 5: ...odels Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outd...

Page 6: ... their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performe...

Page 7: ...tance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include b...

Page 8: ...tion When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refri...

Page 9: ...frigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant reco...

Page 10: ...power consumption during COOL mode use curtains to screen off sunlight and outdoor heat Unit operates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides fresh air ci...

Page 11: ...e DBT Dry bulb temperature WBT Wet bulb temperature 52 30 Can be activated even when the unit is turned off In this condition the unit will operate as a fan with AUTO fan speed and louver swing nanoe G Purifier nanoe G For faster cooling and a longer air throw JETSTREAM Display on remote LCD This operation stops automatically after 1 hours JET STREAM QUIET To enjoy quiet operation This operation r...

Page 12: ...n to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nan...

Page 13: ...t s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 C M Y CM MY CY CMY K ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ACXF55 2705 OL ai 13 3 3 2020 9 56 32 AM ...

Page 14: ... CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON button on Indoor Unit All this should be done within 5 seconds Auto OFF ON Butt...

Page 15: ...nasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Refer ...

Page 16: ... source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2705 OL ai 16...

Reviews: