8.3.2. Indoor unit installation
The mounting wall is strong and solid enough to prevent it from
vibration.
8.3.2.1. Mount the installation plate on
the wall with four installation
plate fixing screws.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
•
•
•
•
Always mount the installation plate horizontally by aligning
the mark-off line with the thread and use a level gauge.
8.3.2.2. Drill the piping hole with Ø70mm
hole-core drill.
•
•
•
•
Line according to the arrows marked on the lower left and
right side of the installation plate.
To drill a hole in the wall and install a sleeve for tube assiy
•
•
•
•
Drill a Ø70mm hole sloping downward toward the outside of
the wall.
•
•
•
•
Insert the sleeve for tube assiy through the hole.
•
•
•
•
Fix the bushing to the sleeve.
•
•
•
•
Extrude 15mm of the sleeve then cut.
Caution
When the wall is horrow, please be sure to use the sleeve
for tube assy to prevent dangers caused by mice biting
the connecting cable.
•
•
•
•
Finish by sealing the sleeve with putty or caulking
compound at the final stage.
29
CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
Summary of Contents for CS-SA9CKP
Page 9: ...3 Dimensions 9 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 10: ...10 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 11: ...4 Refrigeration Cycle Diagram 11 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 12: ...5 Block Diagram 12 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 13: ...6 Wiring Diagram 13 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 17: ...Time Graph for soft dry operation 17 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 26: ...26 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 55: ...13 Exploded View CS SA9CKP CS SA12CKP 55 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 57: ...15 Exploded View CU SA9CKP5 CU SA12CKP5 57 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 61: ...17 1 REMOTE CONTROL 61 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...