Standard for determining operation mode
7.4. Automatic Mode Operation
First Determination:
Second Determination:
One hour after the above determination, the unit will operate according to the table below.
1. Indoor fan operates at super low speed for 20 seconds.
2. After judging indoor air temperature, the operation is determined and operation continued at the mode determined.
3. If indoor temperature is less than 16°C, heating operation will immediately operate.
4. After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation induces cooling
mode operation.
5. If automatic mode operation is started while the unit is operating, operation will continue.
If current operation is in cooling mode (including the cooling mode operation when is a part of Soft Dry mode operation) it will
be maintained, and if current operation is not cooling mode, the appropriate operation mode is determined for 20 seconds at
super slow fan speed.
Then the selected mode will continue.
6. Room temperature adjustment
22
CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
Summary of Contents for CS-SA9CKP
Page 9: ...3 Dimensions 9 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 10: ...10 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 11: ...4 Refrigeration Cycle Diagram 11 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 12: ...5 Block Diagram 12 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 13: ...6 Wiring Diagram 13 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 17: ...Time Graph for soft dry operation 17 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 26: ...26 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 55: ...13 Exploded View CS SA9CKP CS SA12CKP 55 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 57: ...15 Exploded View CU SA9CKP5 CU SA12CKP5 57 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...
Page 61: ...17 1 REMOTE CONTROL 61 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5...