11. Operation Control
11.1 Basic Function
11.1.1 Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting
processes. These shifting processes are depending on the air conditioner settings and the operation environment.
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the
electrical power is supplied to the unit.
11.1.2 Cooling Operation
11.1.2.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5
℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >
Compressor OFF point +0.5K.
11.1.3 Soft Dry Operation
11.1.3.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.5
℃
Remote Control Setting Temp. (16
℃
~30
℃
)
Auto operation Mode Shifting
Powerful Temperature Shifting
Setting Temperature Limit Checking( Min:16
℃
; Max.:30
℃
)
Setting Temperature Limit Checking( Min:16
; Ma
℃
x.:33
)
℃
Internal Setting Temperature
Fan speed Shifting
Dry mode Shifting
Operating Shifting
Cooling/Heating Shifting
Outdoor Temperature Shifting
Summary of Contents for CS-RE9PKE-3
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm...
Page 12: ...12 5 2 Outdoor Unit Unit mm...
Page 14: ...14 7 Block Diagram...
Page 15: ...15 8 Wiring Diagram...
Page 18: ...18 9 2 3 Indoor Unit Installation...
Page 42: ...42 Cooling Characteristic at Different Piping Length...
Page 43: ...43 Heating Characteristic at Different Outdoor Air Temperature...
Page 44: ...44 Heating Characteristic at Different Piping Length...
Page 46: ...46 Cooling Characteristic at Different Piping Length...
Page 47: ...47 Heating Characteristic at Different Outdoor Air Temperature...
Page 48: ...48 Heating Characteristic at Different Piping Length...
Page 50: ...50 Cooling Characteristic at Different Piping Length...
Page 51: ...51 Heating Characteristic at Different Outdoor Air Temperature...
Page 52: ...52 Heating Characteristic at Different Piping Length...
Page 55: ...55 16 2 Outdoor Unit CU RE9PKE 3 CU RE12PKE 3 CU RE15PKE 3...