background image

53 

16.  Exploded View and Replacement Pars List 

16.1  Indoor Unit 

CS-RE9PKE-3, CS-RE12PKE-3, CS-RE15PKE-3 

 

Summary of Contents for CS-RE9PKE-3

Page 1: ...n Code 22 10 3 Operate and Display of Remote Control 23 11 Operation Control 25 11 1 Basic Function 25 11 2 Indoor Fan Motor Operation 27 11 3 Outdoor Fan Motor Operation 28 12 Protection control 30 1...

Page 2: ...wn Self Diagnosis Function 36 14 Disassembly and Assembly Instructions 38 15 Technical Data 41 15 1 Operation Characteristic 41 16 Exploded View and Replacement Pars List 53 16 1 Indoor Unit 53 16 2 O...

Page 3: ...ny substance other than the specified refrigerant eg air etc mix into refrigeration cycle piping Mixing of air etc will cause abnormal high pressure in refrigeration cycle and result in explosio 8 Do...

Page 4: ...acity abnormal high pressure in the refrigeration cycle explosion and injury 27 Must not use other parts except original parts describe in catalog and manual 28 This equipment must be properly earthed...

Page 5: ...70 3660 4390 Running Current A 3 80 5 20 Input Power W 170 820 1150 150 1120 1460 W W 5 29 4 02 3 57 6 00 3 79 3 49 BTU hW 18 06 13 71 12 16 20 47 12 94 11 91 COP kcal h W 4 53 3 46 3 07 5 13 3 27 3 0...

Page 6: ...8 15 49 2 I D O D Height different m ft 10 32 8 10 0 32 8 Additional Gas Amount g m oz ft 20 0 2 20 0 2 Piping Length for Additional Gas m ft 7 0 23 0 7 0 23 0 Inner diameter mm 16 16 Drain Hose Leng...

Page 7: ...r W 210 1385 2280 W W 4 28 3 61 2 98 BTU hW 14 61 12 31 10 17 COP kcal hW 3 66 3 10 2 56 Pdesign H A kW 3 6 Tbivalent 10 SCOP W W 3 4 Annual Consumption kWh 1482 Erp Class A Power Factor 95 dB A H L Q...

Page 8: ...t g m oz ft 20 0 2 Piping Length for Additional Gas m ft 7 23 0 Inner diameter mm 16 Drain Hose Length mm 500 Fin Material Pre coated Fin Type Slit Fin Row x Stage x FPI 2 x 15 x 19 Indoor Heat Exchan...

Page 9: ...te control Quality Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compresso...

Page 10: ...e remote control s default setting POWER GREEN TIMER ORANGE QUIET GREEN INDICATOR POWERFUL RED Air inlet side Air outlet Air inlet rear OFF ON Temperature setting Transmitter Fan speed selection Front...

Page 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm...

Page 12: ...12 5 2 Outdoor Unit Unit mm...

Page 13: ...13 6 Refrigeration Cycle Diagram CS CU RE9PKE 3 CS CU RE12PKE 3 CS CU RE15PKE 3 COOLING HEATING COOLING HEATING...

Page 14: ...14 7 Block Diagram...

Page 15: ...15 8 Wiring Diagram...

Page 16: ...ld not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles which may cause a...

Page 17: ...e wall with 5 screws or more If mounting the unit on the wall consider using anchor bolts Always mount the installation plate horizontally by aligning the marking off line with the thread and using a...

Page 18: ...18 9 2 3 Indoor Unit Installation...

Page 19: ...horizontally by bolt nut 10 mm 2 When installing at roof please consider strong wind and earthquake Please fasten the installation stand firmly with bolt or nails 9 3 2 Connecting the Piping 9 3 2 1 C...

Page 20: ...side valve of the charging set and turn off the vacuum pump Make sure that the needle in the gauge does not move after approximately five minutes Note BE SURE TO FOLLOW THIS PROCEDURE IN ORDER TO AVOI...

Page 21: ...al position with the screw 5 For wiring stripping and connection requirement refer to instruction 9 2 4 of indoor unit 9 3 5 Pipe Insulation 1 Please carry out insulation at pipe connection portion as...

Page 22: ...N When the switch is continuously pressed between 16 to 21 seconds either H14 error detection selection mode or remote controller s signal receiving sound can be cancelled or turned on 10 2 Select Rem...

Page 23: ...ections by pressing AIR SWING button 5 options 10 3 6 QUIET AND POWERFULL button Start Quiet operation Press QUIET button on remote control and then QUIET displays on remote control display QUIET indi...

Page 24: ...If the OFF ON button on the remote control or the AUTO Switch on the indoor unit is pressed the timer setting will be cancelled If Auto Restart Control occurs timer setting will be cancelled During th...

Page 25: ...Thermostat control Compressor is OFF when Intake Air Temperature Internal Setting Temperature 1 5 Compressor is ON after waiting for 3 minutes if the Intake Air Temperature Internal Setting Temperatu...

Page 26: ...ake Air Temperature Internal Setting Temperature Compressor OFF point 0 5K 11 1 5 Automatic Operation Once AUTO mode is selected operation mode is determined by set temperature of remote control and i...

Page 27: ...asic Rotation Speed i Manual Fan speed Fan motor s number of rotation is determined according to remote control setting Remote control O O O O O QUIET Model Tab Hi Me Me Me Lo QLo COOLING rpm 1150 103...

Page 28: ...3 2 Horizontal Airflow The horizontal airflow direction louvers can be adjusted manually by hand 11 3 3 Quiet operation To provide quiet operation comparing to normal operation The Quiet operation ca...

Page 29: ...blinks the possible operation of the unit is operating mode judgment or ON timer sampling If Timer LED blinks there is an abnormal operation occurs 11 3 7 Timer control Delay ON Timer can be set usin...

Page 30: ...he intake air temperature has reached the thermo off temperature However force stop by pressing the OFF ON button at the remote control is permitted or the Auto OFF ON button at indoor unit The reason...

Page 31: ...ient temperature This control starts if all following conditions are achieved Outdoor unit stops or operates in fan mode Outdoor unit has stopped or in fan mode for 120 minutes or more Outdoor unit do...

Page 32: ...ure and outdoor temperature is 20 2 Remote control setting 30 and Hi Fan Speed b Control contents Compressor stops and restart after 3 minutes If the conditions above happen 2 times within 20 minutes...

Page 33: ...h Cooling or Soft Dry Mode Outdoor air temperature is less than 34 This control stopped if anyone of the following conditions is achieved Outdoor air temperature is over 34 Intake air temperature is l...

Page 34: ...420 400 420 400 Time Second 20 100 20 100 20 100 3 Hot Start When the heating operation starts the indoor fan stops and the compressor runs with a certain frequency This is to prevent the cold airflo...

Page 35: ...or temperature 35 C at cooling mode and 7 C at heating mode Compressor operates at rated frequency Different in the intake and outlet air temperatures Normal Value of electric current during operation...

Page 36: ...be restarted using AUTO Switch on the indoor unit In forced operation the frequency for compressor and fan speed can not be changed and the signal receiving sound is different Normal Operation ON pep...

Page 37: ...isconnected H33 Incorrect connection of Indoor Outdoor cable Indoor outdoor supply voltage H97 Outdoor fan motor lock Twice within 30 minutes Outdoor fan motor H98 Indoor high pressure protection Air...

Page 38: ...ailure to heed this caution may result in electric shocks 1 Open the intake grille and pull it to the horizontal position 2 Pull up the intake grille until it falls off 1 Remove the two caps at the di...

Page 39: ...he whole electronic controller Be sure to avoid cracking of the supporting hook 3 Remove the control board complete Loose the screws of control board complete then the whole control board can be pulle...

Page 40: ...nd pull out the whole evaporator 2 Loose the fixing screw of the cross flow fan 3 After removing the bearing indoor fan can be taken out from the left side 4 Lift up the indoor fan slightly and then p...

Page 41: ...41 15 Technical Data 15 1 Operation Characteristic 15 1 1 CS RE9PKE 3 CU RE9PKE 3 Cooling Characteristic at Different Outdoor Air Temperature...

Page 42: ...42 Cooling Characteristic at Different Piping Length...

Page 43: ...43 Heating Characteristic at Different Outdoor Air Temperature...

Page 44: ...44 Heating Characteristic at Different Piping Length...

Page 45: ...45 15 1 2 CS RE12PKE 3 CU RE12PKE 3 Cooling Characteristic at Different Outdoor Air Temperature...

Page 46: ...46 Cooling Characteristic at Different Piping Length...

Page 47: ...47 Heating Characteristic at Different Outdoor Air Temperature...

Page 48: ...48 Heating Characteristic at Different Piping Length...

Page 49: ...49 15 1 3 CS RE15PKE 3 CU RE15PKE 3 Cooling Characteristic at Different Outdoor Air Temperature...

Page 50: ...50 Cooling Characteristic at Different Piping Length...

Page 51: ...51 Heating Characteristic at Different Outdoor Air Temperature...

Page 52: ...52 Heating Characteristic at Different Piping Length...

Page 53: ...53 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS RE9PKE 3 CS RE12PKE 3 CS RE15PKE 3...

Page 54: ...WER SUPPLY CORD COMPLETE 1 CWA20C3090 CWA20C3090 CWA20C3107 18 MAIN PCB 1 CWA73C6898 CWA73C6899 CWA73C6900 19 SENSOR 1 CWA50C2755 CWA50C2883 CWA50C2883 20 INDICATOR HOLDER FRONT 1 CWD933546 CWD933546...

Page 55: ...55 16 2 Outdoor Unit CU RE9PKE 3 CU RE12PKE 3 CU RE15PKE 3...

Page 56: ...ND PROOF MATERIAL 1 CWG302809 CWG302815 CWG302815 20 SOUND PROOF MATERIAL 1 CWG302693 21 SOUND PROOF MATERIAL 1 CWG302732 CWG302732 CWG302732 22 SOUND PROOF MATERIAL 1 CWG302791 CWG302791 23 TUBE NOIS...

Reviews: