33
Indoor fan speed changes according to the indoor piping temperature. In up zone shown below, the fan speed
increases by +50r/min until the indoor piping temperature reaches 9
℃
(cooling)/5
℃
(dry) or above for 5 minutes.
However, the control is unavailable within 4 minutes after compress stars up.
12.2.3 Dew Prevention Control
• To prevent dew formation at indoor unit discharge area.
• This control starts if all conditions continue for 20 minutes:
- Operated with Cooling or Soft Dry Mode.
- Outdoor air temperature is less than 34
℃
.
• This control stopped if anyone of the following conditions is achieved:
- Outdoor air temperature is over 34
℃
.
- Intake air temperature is less than 24
℃
.
- Operation without Cooling or Soft Dry Mode.
12.2.4 Overload Protection For Cooling Operation
Frequency of the compressor will change according to the outdoor piping temperature.
12.3 Indoor Piping Air Temperature Control (Heating)
12.3.1 Indoor Fan Control
1. Indoor fan is controlled by the indoor piping temperature.
●
Manual Fan Speed
Piping Temperature(
℃
)
K0
K1
K2
K3
K4
K5
K6
K7
K8
K9
K10
K11
16
19
24
32
32
36
36
39
54
54
57
-
●
Auto Fan Speed
Summary of Contents for CS-RE9PKE-3
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm...
Page 12: ...12 5 2 Outdoor Unit Unit mm...
Page 14: ...14 7 Block Diagram...
Page 15: ...15 8 Wiring Diagram...
Page 18: ...18 9 2 3 Indoor Unit Installation...
Page 42: ...42 Cooling Characteristic at Different Piping Length...
Page 43: ...43 Heating Characteristic at Different Outdoor Air Temperature...
Page 44: ...44 Heating Characteristic at Different Piping Length...
Page 46: ...46 Cooling Characteristic at Different Piping Length...
Page 47: ...47 Heating Characteristic at Different Outdoor Air Temperature...
Page 48: ...48 Heating Characteristic at Different Piping Length...
Page 50: ...50 Cooling Characteristic at Different Piping Length...
Page 51: ...51 Heating Characteristic at Different Outdoor Air Temperature...
Page 52: ...52 Heating Characteristic at Different Piping Length...
Page 55: ...55 16 2 Outdoor Unit CU RE9PKE 3 CU RE12PKE 3 CU RE15PKE 3...