13.2.2 Freeze Prevention Control
1 .Frequency of the compressor
For prevention of freezing of the indoor evaporator, the frequency of the
compressor will be changed according to the indoor piping temperature.
2 .Indoor Fan Control
Indoor fan speed changes according to the indoor fan speed.
13.2.3 Dew Prevention Control
• To prevent dew formation at indoor unit discharge area.
• This control starts if all conditions continue for 20 minutes:
- Operated with Cooling or Soft Dry Mode.
- Indoor intake temperature is between 255
к
and 295
к
.
- Outdoor air temperature is less than 305
к
.
- Quiet Lo fan speed.
• This control stopped then receive air swing change signal from Remote Control.
13.2.4 Overload Protection For Cooling Operation
The frequency for the compressor will change according to the outdoor piping temperature.
13.3 Outdoor Air Temperature Control
13.3.1 Indoor Fan Control
1. Indoor fan is controlled by the indoor piping temperature.
ϥ
Manual Fan Speed
Piping Temperature(
к
)
Summary of Contents for CS-RE9HKE
Page 11: ...11 5 Dimensions 5 1 Indoor Unit...
Page 12: ...12 5 2 Outdoor Unit Unit mm...
Page 13: ...13 6 Refrigeration Cycle Diagram...
Page 14: ...14 7 Block Diagram...
Page 16: ...16 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW...
Page 17: ...17 BOTTOM VIEW...
Page 18: ...18 9 1 2 Indicator TOP VIEW BOTTOM VIEW...
Page 21: ...21 10 2 3 Indoor Unit Installation...
Page 38: ...38 14 2 3 Error Codes Table...
Page 40: ...40...
Page 41: ...41...
Page 42: ...42 16 Exploded View and Replacement Pars List 16 1 Indoor Unit 35 36 38 37...
Page 44: ...44 16 2 Outdoor Unit...