above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air
conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air
conditioner is stopped using remote control, the vane will shift to close position.
12.3.2 Horizontal
Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.3.3 Quiet operation
ϥ
To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing
QUIET/POWERFUL buttons at remote control.
ϥ
Once Quiet mode is active ,the unit will continuously operate in QUIET Mode until cancel the mode by pressing
QUIET/POWERFUL buttons at remote control.
12.3.4 Powerful
operation
ϥ
To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or
stop by pressing QUIET/POWERFUL buttons at remote control.
ϥ
When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode
by pressing QUIET/POWERFUL buttons at remote control. Operation details are as the fig. below.
1. For cooling, soft Dry mode
Power Button pressed
PIPING
TEMP.
(COOLING)
FAN SPEED
( rpm)
ON
OFF
AUTO
45 seconds
20 ‘
Shi
20 ‘
Fast Cooling
Cooling, Soft Dry
Min.5’
Correction
Factor(
)
ć
-0.25
+0.25
-1.67
-1.00
A
B
C
D
20 ‘
20 ‘
1130 (Max)
730 (Min.)
2. For
Heating
mode:
Power Button pressed
ON
OFF
AUTO
45 seconds
20 ‘
Shi
20 ‘
Fast Heating1
Heating
Min.5’
+0.25
+0.25
+2
+1.00
A
B
C
D
20 ‘
20 ‘
1270 (Max)
940 (Min.)
PIPING
TEMP.
(COOLING)
FAN SPEED
( rpm)
Correction
Factor(
)
ć
Note: The value of A, B, C, D will change according to the indoor temperature.
Summary of Contents for CS-RE9HKE
Page 11: ...11 5 Dimensions 5 1 Indoor Unit...
Page 12: ...12 5 2 Outdoor Unit Unit mm...
Page 13: ...13 6 Refrigeration Cycle Diagram...
Page 14: ...14 7 Block Diagram...
Page 16: ...16 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW...
Page 17: ...17 BOTTOM VIEW...
Page 18: ...18 9 1 2 Indicator TOP VIEW BOTTOM VIEW...
Page 21: ...21 10 2 3 Indoor Unit Installation...
Page 38: ...38 14 2 3 Error Codes Table...
Page 40: ...40...
Page 41: ...41...
Page 42: ...42 16 Exploded View and Replacement Pars List 16 1 Indoor Unit 35 36 38 37...
Page 44: ...44 16 2 Outdoor Unit...