7
Control Device
Expansion Valve
Refrigerant Oil
cm
3
RB68A or Freol Alpha68M (400)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 930 (32.8)
Height(I/D / O/D)
mm (inch)
290 (11-7/16) / 540 (21-9/32)
Width (I/D / O/D)
mm (inch)
870 (34-9/32) / 780 (30-23/32)
Dimension
Depth (I/D / O/D)
mm (inch)
204 (8-1/16) / 289 (11-13/32)
Weight
Net (I/D / O/D)
kg (lb)
9 (20) / 35 (77)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8.) ~ 15 (49.2)
I/D & O/D Height different
m (ft)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 19
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 24 x 17
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
36.4 x 504 x 725:713
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
DRY BULB
WET BULB
Cooling Maximum
32
23
Heating Minimum
16
11
Cooling Maximum
30
-
Heating Minimum
16
-
Maximum 10
-
Indoor
Operation
Range
+8/10°C HEAT
Minimum 8
-
Cooling Maximum
43
26
Heating Minimum
-15
-
Cooling Maximum
24
18
Heating Minimum
-15
-
Maximum -
-
Outdoor
Operation
Range
+8/10°C HEAT
Minimum -15
-
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
6.
Maximum heating capacity shown are the values based on powerful operation.
7.
If the EUROEVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with
rated voltage 230V shall be used.
8.
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode.
Summary of Contents for CS-QE12MKE
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit ...
Page 14: ...14 5 2 Outdoor Unit ...
Page 15: ...15 6 Refrigeration Cycle Diagram ...
Page 16: ...16 7 Block Diagram ...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 18: ...18 8 2 Outdoor Unit ...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 20: ...20 9 2 Outdoor Unit ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 24: ...24 10 2 Outdoor Unit ...
Page 52: ...52 15 3 Error Code Table ...
Page 53: ...53 ...
Page 80: ...80 16 1 3 To remove discharge grille ...
Page 81: ...81 16 1 3 1 To remove control board 16 1 4 To remove cross flow fan and indoor fan motor ...
Page 82: ...82 ...
Page 84: ...84 17 Technical Data 17 1 Operation Characteristics 17 1 1 CU QE9MKE ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 17 1 2 CU QE12MKE ...
Page 89: ...89 ...
Page 90: ...90 ...
Page 91: ...91 ...